Your browser doesn't support javascript.
loading
Validación de la evaluación por ultrasonido de la vaina del nervio óptico para la cuantificación de la presión intracraneana en grandes altitudes / Validation of the ultrasound evaluation of the optic nerve sheath for the quantification of intracranial pressure at high altitudes
García Montalvo, Gabriel Ricardo; Ramos Tituaña, Edison Taquiño; Martínez Burbano, Braulio Alexander.
  • García Montalvo, Gabriel Ricardo; Hospital de Especialidades Carlos Andrade Marín. Unidad Técnica de Adultos. Área de Cuidados Intensivos. Quito. EC
  • Ramos Tituaña, Edison Taquiño; Hospital de Especialidades Carlos Andrade Marín. Coordinación de Áreas Críticas. Quito. EC
  • Martínez Burbano, Braulio Alexander; Hospital de Especialidades Carlos Andrade Marín. Unidad Técnica de Neurología. Quito. EC
Cambios rev. méd ; 18(1): 58-62, 28/06/2019. tabs
Article in Spanish | LILACS | ID: biblio-1015162
RESUMEN
INTRODUCCIÓN. La medición del diámetro de la vaina del nervio óptico a través de la ventana ocular puede ser un método no invasivo para la detección de hipertensión endocraneana. OBJETIVO. De este trabajo fue validar una fórmula de cuantificación de la presión intracraneana a partir de la evaluación por ultrasonido de la vaina del nervio óptico en una ciudad de gran altitud. MATERIALES Y MÉTODOS. Estudio prospectivo de 27 pacientes con trauma craneoencefalico grave en quienes se les colocó un sensor de presión intracraneana intraventricular y se realizó el cálculo de la PIC no invasiva mediante correlación utilizando la evaluación de la vaina del nervio óptico a través de ultrasonido y aplicando una fórmula de cálculo. RESULTADOS. Correlación positiva débil con significancia estadística. CONCLUSIÓN. La cuantificación de la presión intracraneana no invasiva a través de la evaluación de la vaina del nervio óptico por ultrasonido podría ser una herramienta útil en ciudades de gran altitud sobre el nivel del mar.
ABSTRACT
INTRODUCTION. Measuring the diameter of the optic nerve sheath through the eye window can be a non-invasive method for the detection of endocranial hypertension. OBJECTIVE. This work was to validate a formula for quantifying intracranial pressure from the ultrasound evaluation of the optic nerve sheath in a high-altitude city. MATERIALS AND METHODS. Prospective study of 27 patients with severe cranioencephalic trauma in whom an intraventricular intracranial pressure sensor was placed and the calculation of non-invasive ICP was performed by correlation using the evaluation of the optic nerve sheath through ultrasound and applying a formula of calculation. RESULTS. Weak positive correlation with statistical significance. CONCLUSION. Quantification of non-invasive intracranial pressure through the evaluation of the optic nerve sheath by ultrasound could be a useful tool in high altitude cities above sea level.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Optic Nerve / Ultrasonic Therapy / Observational Study / Craniocerebral Trauma / Hypertension Type of study: Observational study Limits: Adult / Humans Country/Region as subject: South America / Ecuador Language: Spanish Journal: Cambios rev. méd Journal subject: Medicine / Public Health Year: 2019 Type: Article Affiliation country: Ecuador Institution/Affiliation country: Hospital de Especialidades Carlos Andrade Marín/EC

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Optic Nerve / Ultrasonic Therapy / Observational Study / Craniocerebral Trauma / Hypertension Type of study: Observational study Limits: Adult / Humans Country/Region as subject: South America / Ecuador Language: Spanish Journal: Cambios rev. méd Journal subject: Medicine / Public Health Year: 2019 Type: Article Affiliation country: Ecuador Institution/Affiliation country: Hospital de Especialidades Carlos Andrade Marín/EC