INTRODUCCIÓN:
La embolización de cuerpos extraños intravasculares es una complicación poco frecuente; sin embargo, está asociada a alteraciones cardíacas y pulmonares en más del 50% de los casos. Actualmente se prefiere realizar el manejo utilizando técnicas de extracción por cateterismo cardíaco, esto debido a la naturaleza menos invasiva del procedimiento y a las menores tasas de mortalidad y complicaciones asociadas. A continuación se presenta un reporte de caso donde se realizó la extracción un catéter intracardiaco mediante vía percutánea. CASO CLÍNICO Lactante de sexo masculino, de 51 días de vida, con antecedentes de prematuridad extrema y peso adecuado para edad gestacional, ingresado en el servicio de neonatología; a quien como acceso vascular central se le colocó un catéter percutáneo femoral. Tras el retiro del mismo se apreció rotura y embolización de los dos tercios distales; la evaluación radiológica evidenció catéter a nivel de cavidades cardíacas derechas. EVOLUCIÓN Se inició antibioticoterapia por el riesgo de infección asociado. De forma exitosa se realizó la extracción del cuerpo extraño por intervencionismo percutáneo; el paciente evolucionó favorablemente, no presentó ninguna complicación.CONCLUSIÓN:
La rotura y embolización del catéter es un evento poco frecuente que incrementa la morbimortalidad de los pacientes ingresados en neonatología. La extracción percutánea debe ser la primera opción por la eficacia y seguridad del procedimiento.(au)ABSTRACT
BACKGROUND:
The embolization of foreign intravascular bodies is a rare complication; however, it is associated with cardiac and pulmonary dysfunction in more than 50% of cases. Currently, it is preferred to perform the management using extraction techniques by cardiac catheterization; this is explained by the less invasive nature of the procedure and the lower mortality and complications rates. The following is a case report where an intracardiac catheter was extracted by a percutaneous procedure. CASE REPORT Male, 52-day-old infant, with history of extreme prematurity and adequate weight for gestational age; hospitalized in the neonatology service; as central vascular access a percutaneous femoral catheter was placed. After removal, rupture and embolization of the distal two thirds were observed; the radiological evaluation showed a catheter at the level of right heart cavities. EVOLUTION By the associated infection risk, antibiotic therapy was initiated. The foreign body was extracted successfully by percutaneous intervention; the patient presented a favorable evolution without any complications.CONCLUSIONS:
The catheter rupture and embolization is a rare event that increases morbidity and mortality rates of patients admitted to neonatology. Percutaneous extraction should be the first option by the procedure efficacy and safety.(au)
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Catheterization
/
Embolism
/
Femoral Vein
Limits:
Humans
/
Infant
/
Male
Language:
Spanish
Journal:
Rev. méd. Hosp. José Carrasco Arteaga
Journal subject:
Medicina
/
Sa£de P£blica
Year:
2019
Type:
Article
Affiliation country:
Ecuador
Institution/Affiliation country:
Clínica Santa Inés/EC
/
Hospital de Especialidades José Carrasco Arteaga/EC
/
Universidad Católica de Cuenca/EC
/
Universidad de Cuenca/EC