Your browser doesn't support javascript.
loading
LC-UV method to assay raloxifene hydrochloride in rat plasma and its application to a pharmacokinetic study
Fontana, Márcia Camponogara; Laureano, João Víctor; Forgearini, Betielli; Chaves, Paula dos Santos; Araujo, Bibiana Verlindo de; Beck, Ruy Carlos Ruver.
  • Fontana, Márcia Camponogara; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. PPG em Ciências Farmacêuticas. Porto Alegre. BR
  • Laureano, João Víctor; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. PPG em Ciências Farmacêuticas. Porto Alegre. BR
  • Forgearini, Betielli; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. Porto Alegre. BR
  • Chaves, Paula dos Santos; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. PPG em Ciências Farmacêuticas. Porto Alegre. BR
  • Araujo, Bibiana Verlindo de; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. PPG em Ciências Farmacêuticas. Porto Alegre. BR
  • Beck, Ruy Carlos Ruver; Universidade Federal do Rio Grande do Sul. Faculdade de Farmácia. PPG em Ciências Farmacêuticas. Porto Alegre. BR
Braz. J. Pharm. Sci. (Online) ; 55: e18052, 2019. tab, graf
Article in English | LILACS | ID: biblio-1039069
ABSTRACT
A specific, precise, and accurate LC-UV method was developed and validated to assay raloxifene hydrochloride in rat plasma. Raloxifene was analyzed after liquid-liquid extraction and quantified by reversed phase liquid chromatography (C18 column) using acetonitrile and ammonium acetate buffer 0.05 M (pH 4.0) as mobile phase at a flow rate of 1 mL.min-1 and UV detection at 287 nm. Retention times of raloxifene and internal standard (dexamethasone) were approximately 11 min and 14 min, respectively. Linearity was checked for a concentration range between 25 ng.mL-1 and 1000 ng.mL-1. Intra- and inter-day precision had relative standard deviation lower than 10% and 15%, respectively. Recovery from plasma was higher than 90%. Accuracy values were 98.21%, 99.70%, and 102.70% for lower, medium, and upper limits of quantification, respectively. Limit of quantification was 25 ng.mL-1. Drug stability was analyzed at room temperature using plasma kept in a freezer at -80 °C for 45 days after processing for 6 h and three freeze-thaw cycles. The advantages of the method developed include stability under different conditions and low limit of quantification. Its applicability was confirmed by the analysis of raloxifene levels in plasma samples in a designed pharmacokinetic study in rats after intravenous administration (5 mg.kg-1).
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Plasma / Raloxifene Hydrochloride / Chromatography, Reverse-Phase Limits: Animals Language: English Journal: Braz. J. Pharm. Sci. (Online) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2019 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Sul/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Plasma / Raloxifene Hydrochloride / Chromatography, Reverse-Phase Limits: Animals Language: English Journal: Braz. J. Pharm. Sci. (Online) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2019 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Sul/BR