Your browser doesn't support javascript.
loading
Evaluación del desempeño de dos pruebas para la detección de antígeno de Helicobacter pylori en heces / Evaluation of the accuracy of two stool antigen tests for Helicobacter pylori infection
Nguyen Thi, Huong; Falcón Márquez, Rosabel; Vázquez Ramudo, Susana; Almaguer Rodríguez, Tatiana; Tamayo Brito, Celia; Corrales Sánchez, Rosabel; Escobar Capote, María Del Pilar; González García, Ariadna; Gutiérrez González, Oderay; Llanes Caballero, Rafael.
  • Nguyen Thi, Huong; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Falcón Márquez, Rosabel; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Vázquez Ramudo, Susana; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Almaguer Rodríguez, Tatiana; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Tamayo Brito, Celia; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Corrales Sánchez, Rosabel; Policlínico Eduardo Díaz. Artemisa. CU
  • Escobar Capote, María Del Pilar; Policlínico Pedro Borrás. La Habana. CU
  • González García, Ariadna; Policlínico Pedro Borrás. La Habana. CU
  • Gutiérrez González, Oderay; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
  • Llanes Caballero, Rafael; Instituto de Medicina Tropical Pedro Kourí. La Habana. CU
Rev. cuba. med. trop ; 69(1): 1-7, ene.-abr. 2017.
Article in Spanish | LILACS, CUMED | ID: biblio-1042914
RESUMEN
Introducción: la detección de antígeno en heces se ha considerado una prueba prometedora para el diagnóstico de la infección por Helicobacter pylori. Para su introducción en la práctica médica, es un requisito indispensable demostrar el desempeño adecuado del método en la población de estudio. Objetivo: evaluar la capacidad diagnóstica de los sistemas comerciales ELISA SD y SD BIOLINE, del fabricante Standard Diagnostics, Corea, en pacientes cubanos con síntomas gastroduodenales. Métodos: se evaluaron 101 muestras de heces de pacientes previamente clasificados como H. pylori positivos y negativos por las pruebas de referencia de histología y prueba rápida de la ureasa. Se calcularon los parámetros de desempeño de ambos sistemas diagnósticos por el programa EPIDAT 3.1. Resultados: la sensibilidad para los sistemas ELISA SD y SD BIOLINE fue de 85,25 por ciento y 75,41 por ciento, respectivamente. La especificidad para ambos fue de 92,50 por ciento. Los valores predictivos positivos y negativos, los índices de validez y de Youden y la confiabilidad diagnóstica de ambas pruebas fueron satisfactorios. Conclusiones: Los sistemas evaluados exhibieron un desempeño comparable con la histología y la prueba rápida de ureasa para la detección activa de la infección por H. pylori, lo que demuestra su utilidad para el diagnóstico y el manejo oportuno del paciente, sin la necesidad de emplear pruebas invasivas(AU)
ABSTRACT
Introduction: stool antigen tests have been considered to be promising for the diagnosis of Helicobacter pylori infection. For their incorporation into medical practice, it is indispensable to demonstrate their accuracy in a study population. Objective: evaluate the diagnostic capacity of the commercial systems ELISA SD and SD BIOLINE, Standards Diagnostics, Korea, in Cuban patients with gastroduodenal symptoms. Methods: an evaluation was conducted of 101 stool samples from patients previously classified as H. pylori positive and negative by reference histological tests and the rapid urease test. Estimation was made of performance parameters for both diagnostic systems using the software EPIDAT 3.1. Results: Sensitivity for the systems ELISA SD and SD BIOLINE was 85.25 percent and 75.41 percent, respectively. Specificity for both was 92.50 percent. Positive and negative predictive values, validity and Youden's indices, and diagnostic reliability were satisfactory for both tests. Conclusions: the systems evaluated were found to have a performance level comparable with histological tests and the rapid urease test for active detection of H. pylori infection. This confirms their usefulness for the diagnosis and timely management of patients without having to use invasive tests(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Enzyme-Linked Immunosorbent Assay / Feces / Antigens Type of study: Diagnostic study / Practice guideline / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2017 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto de Medicina Tropical Pedro Kourí/CU / Policlínico Eduardo Díaz/CU / Policlínico Pedro Borrás/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Enzyme-Linked Immunosorbent Assay / Feces / Antigens Type of study: Diagnostic study / Practice guideline / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. med. trop Journal subject: Tropical Medicine Year: 2017 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto de Medicina Tropical Pedro Kourí/CU / Policlínico Eduardo Díaz/CU / Policlínico Pedro Borrás/CU