Desarrollo de un material de referencia certificado para análisis elemental de agua potable / Development of a certified reference material for elemental analysis of drinking wáter / Desenvolvimento de um material de referência certificado para análise elementar de água potável
Ahumada-FoNgua, Diego A.; Soto-Morales, Luis L.; Morales-Erazo, Laura V.; Abella-Gamba, Johanna P..
  • Ahumada-FoNgua, Diego A.; Instituto Nacional de Metrología de Colombia. Grupo de investigación en metrología química y bionálisis.
  • Soto-Morales, Luis L.; Instituto Nacional de Metrología de Colombia. Grupo de investigación en metrología química y bionálisis.
  • Morales-Erazo, Laura V.; Instituto Nacional de Metrología de Colombia. Grupo de investigación en metrología química y bionálisis.
  • Abella-Gamba, Johanna P.; Instituto Nacional de Metrología de Colombia. Grupo de investigación en metrología química y bionálisis.
Rev. colomb. quím. (Bogotá) ; 48(3): 36-44, sep.-dic. 2019. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1058426
RESUMEN
Resumen La producción de un material de referencia (MR) es un proceso en el que se realizan estudios relacionados con la preparación, envasado y caracterización (incluye homogeneidad y estabilidad). En este trabajo se presentan los resultados del desarrollo de un MR de agua potable. El envasado se realiza aplicando dos procedimientos (envasado convencional e inmersión). La caracterización se realizó por Absorción Atómica, ICPMS y Cromatografía iónica. La evaluación de homogeneidad del material se realizó para Na, Mg, Ca, Fe, K, Co, Pb, Mo, As, Ni, Se, Cu, Al, Cr Zn y aniones como NO3 - y Cl-. La estabilidad se evaluó a corto (condiciones aceleradas) y largo plazo por ICPMS y CI, además se realizó seguimiento gravimétrico. La homogeneidad y estabilidad se evaluaron con base en su incertidumbre. La incertidumbre asociada a la homogeneidad y estabilidad MR evidenció resultados aceptables para la mayoría de los analitos. Los resultados del seguimiento gravimétrico permitieron detectar pérdidas de masa del material, por lo que se planteó un nuevo esquema para evaluar la estabilidad a través de métodos gravimétricos. Finalmente, se encontró que el MR presenta incertidumbres expandidas entre el 0,93% y el 4,38%, siendo apto para el uso previsto.
ABSTRACT
Abstract The production of reference materials (RM) is a process that involves carrying out different studies related to the preparation, packaging and chemical stability of the analytes. This paper presents the results of the development of a drinking water RM. The packaging is done by applying two procedures (conventional packaging and immersion). The characterization of this material was carried out through atomic absorption, ICPMS and ion chromatography. The assessment of the homogeneity of the material was carried out for Na, Mg, Ca, Fe, K, Co, Pb, Mo, As, Ni, Se, Cu, Al, Cr Zn and anions as NO3 - y Cl-. The stability studies were evaluated in the short term (accelerated conditions), and long term by ICPMS and IC, and gravimetric monitoring was also performed. Homogeneity and stability were evaluated based on their uncertainty. The uncertainty associated with homogeneity and MR stability evidenced acceptable results for most analytes. The results of the gravimetric monitoring allowed to detect losses of mass of the material, reason why a new scheme was proposed to evaluate the stability through gravimetric methods. Finally, it was found that the RM presents expanded uncertainties between 0,93% and 4,38%, which makes it suitable for the intended use.
RESUMO
Resumo Este artigo apresenta os resultados do desenvolvimento de um MR de água potável. A embalagem é feita aplicando dois procedimentos (embalagem convencional e imersão). A caracterização foi realizada por Absorção Atômica, ICPMS e Cromatografia Iônica. A avaliação da homogeneidade do material foi realizada para Na, Mg, Ca, Fe, K, Co, Pb, Mo, As, Ni, Se, Cu, Al, Cr Zn e ânions como NO3 - y Cl-. A estabilidade foi avaliada em curto prazo (condições aceleradas) e em longo prazo pelo ICPMS e IC, e também foi realizada monitoração gravimétrica. A homogeneidade e estabilidade foram avaliadas com base na incerteza. A incerteza associada à homogeneidade e estabilidade da RM evidenciou resultados aceitáveis para a maioria dos analitos. Os resultados do monitoramento gravimétrico permitiram detectar perdas de massa do material, pelo que foi proposto um novo esquema para avaliar a estabilidade por métodos gravimétricos. Por fim, verificou-se que o RM apresenta incertezas expandidas entre 0,93% e 4,38%, sendo adequado para o uso pretendido.