Your browser doesn't support javascript.
loading
Adaptación de cofias Cobalto-Cromo confeccionadas con dos técnicas de colado sobre dos líneas de terminación / Fit of Cobalt-Chromium alloy copings fabricated with two casting techniques on two termination lines
Pantoja Borja, Pedro Estephano; Geldres Echeverría, Graciela María Dolores; Castillo Andamayo, Diana Esmeralda; Quintana del Solar, Martín Gilberto.
  • Pantoja Borja, Pedro Estephano; Universidad Internacional del Ecuador. Facultad de Odontología. Quito. EC
  • Geldres Echeverría, Graciela María Dolores; Universidad Nacional de Trujillo. Facultad de Odontología. Trujillo. PE
  • Castillo Andamayo, Diana Esmeralda; Universidad Peruana Cayetano Heredia. Facultad de Estomatología. Lima. PE
  • Quintana del Solar, Martín Gilberto; Universidad Peruana Cayetano Heredia. Facultad de Estomatología. Lima. PE
Rev. estomatol. Hered ; 29(2): 115-127, abr. 2019. ilus, tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1058490
RESUMEN
Las técnicas de cera perdida colado por centrifugación convencional, son técnicas vigentes para obtener cofias de Cobalto-Cromo (Co-Cr) para coronas metalcerámica.

Objetivo:

Evaluar in vitro, la adaptación marginal e interna de cofias unitarias de aleación Co-Cr, realizadas sobre dos líneas de terminación chamfer y bisel, fabricadas con las técnicas de cera perdida colada por centrifugación convencional (CPCC) y por inducción (CPCI). Materiales y métodos Se evaluó la adaptación marginal e interna de 13 cofias unitarias de aleacion Co-Cr para cada tecnica y línea de terminación, usando la técnica de replica de silicona. Las muestras fueron divididas en sentido vestíbulo-palatino y en sentido mesio-distal, observadas en un estéreomicroscopio a un aumento de 40X y se evaluó la zona cervical, axial y oclusal.

Resultados:

Los analisis estadisticos incluyeron la prueba t de Student y U Mann-Whitney, previamente se evaluo los supuestos de normalidad con la prueba de Shapiro-Wilk para analizar diferencias estadisticamente significativas entre los grupos (p<0.05). La discrepancia marginal fue menor a 120 µm y la discrepancia interna menor a 350µm para ambas líneas de terminación y técnica de colado.

Conclusiones:

Los resultados en la adaptación marginal e interna de cofias con líneas de terminación chamfer y bisel fabricadas con las técnicas de cera perdida colada por centrifugación convencional e inducción, los valores descriptivos no fueron concluyentes, ya que en la mayoría de los puntos evaluados no existió diferencia estadísticamente significativa. Además en las dos líneas de terminación chamfer y bisel se encontraron rangos clínicamente aceptables.
ABSTRACT
The techniques of lost wax cast by conventional centrifugation are current techniques to obtain Cobalt-Chrome (Co-Cr) copings for metalceramic crowns.

Objective:

Evaluate in vitro, the marginal and internal adaptation in unitary Co-Cr alloy copes, made on two termination lines chamfer and bevel, manufactured with the techniques of lost wax cast by conventional centrifugation (CPCC) and by induction (CPCI), according to type of cut, area and measurement points. Materials and

methods:

The marginal and internal adaptation of 13 co-units of Co-Cr alloy for each technique and termination line was evaluated. The silicone replication technique was used. The samples were divided in the vestibulo-palatal direction and in the mesio-distal direction, observed in a stereomicroscope at a 40X magnification and the cervical, axial and occlusal areas were evaluated.

Results:

Statistical analyzes included the Student’s t-test and U Mann-Whitney, previously the assumptions of normality were evaluated with the Shapiro-Wilk test to analyze statistically significant differences between the groups (p <0.05). The marginal discrepancy was less than 120 µm and the internal discrepancy less than 350µm.

Conclusion:

The results in the marginal and internal adaptation of copings with chamfer termination lines and bevel fabricated with the techniques of lost wax cast by conventional centrifugation and induction were not conclusive to determine which technique is the best since in most of the points evaluated there was not a statistically significant difference. Also in the two lines of termination cnamfer and bevel, there were found clinical acceptable ranges.


Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Rev. estomatol. Hered Journal subject: Medicina Bucal / Dentistry Year: 2019 Type: Article Affiliation country: Ecuador / Peru Institution/Affiliation country: Universidad Internacional del Ecuador/EC / Universidad Nacional de Trujillo/PE / Universidad Peruana Cayetano Heredia/PE

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Rev. estomatol. Hered Journal subject: Medicina Bucal / Dentistry Year: 2019 Type: Article Affiliation country: Ecuador / Peru Institution/Affiliation country: Universidad Internacional del Ecuador/EC / Universidad Nacional de Trujillo/PE / Universidad Peruana Cayetano Heredia/PE