Comparación entre los sistemas manual de limas de acero inoxidable y el rotatorio de limas de níquel titanio, en la conformación de conductos radiculares curvos in vitro / Comparison between the manual system of stainless steel files and the rotating system of nickel titanium files in the conformation of curved radicular ducts in vitro
Odontol. vital
; (31): 31-36, jul.-dic. 2019. tab, graf
Article
in Es
| LILACS, BBO
| ID: biblio-1091425
Responsible library:
CR1.1
RESUMEN
Resumen Introducción:
Estudio experimental donde se procuró comparar el efecto del sistema manual y del rotatorio sobre la conformación de conductos curvos.Metodología:
Una muestra de 40 raíces mesiales de primeras molares inferiores fue aleatorizada en dos grupos iguales grupos sistema manual de limas K y sistema rotatorio FGK Race®. Se comparó el radio de la curvatura final vs. el inicial mediante el programa Autocat 2015. Se empleó la prueba t con significancia de 0,05.Resultados:
El radio de la curvatura varió de manera significativa, tanto para sistema manual como para el rotatorio FGK Race® (p=0,0001 y p=0,0013, respectivamente). Además, el sistema manual produjo mayor variación en el radio de la curvatura al compararlo con el sistema rotatorio 2,23 mm vs. 1,27 mm respectivamente; p=0,13.Conclusiones:
Ambos sistemas produjeron modificación en la conformación de los conductos mesiales; sin embargo, en la comparación entre ambos dichas diferencias no fueron significativas.ABSTRACT
Abstract Introduction:
An experimental study was carried out to compare the effect of the manual system and the rotary system on the conformation of curved conduits.Methodology:
A sample of 40 mesial roots of lower first molars was randomized into two equal groups group manual system of K-files and group rotary system FGK Race®. The radius of the final curvature vs. the initial curvature was compared using the Autocat 2015 program. The t-test with a significance of 0.05 was used.Results:
The curvature radius varied significantly for both the manual system and the rotary FGK Race® (p = 0.0001 and p = 0.0013, respectively). In addition, the manual system produced greater variation in the radius of the curvature when compared to the rotary system 2.23mm vs. 1.27mm respectively; p = 0.13.Conclusion:
Both systems produced modification on the conformation of the conduits of the mesial roots; however, in the comparison between both systems said differences were not significant.Key words
Full text:
1
Index:
LILACS
Main subject:
Stainless Steel
/
Titanium
/
Dental Instruments
/
Dental Pulp Cavity
/
Molar
/
Nickel
Type of study:
Clinical_trials
Language:
Es
Journal:
Odontol. vital
Journal subject:
Odontologia
Year:
2019
Type:
Article