Evaluación de la estabilidad dimensional del cemento endodóntico sellador Adseal® / Evaluation of the dimensional stability of endodontic sealing cement Adseal®
García Zúñiga, Paola; Ortega Palomino, Juan Pablo; García Orozco, Stephania; Pérez Jaramillo, Adolfo; Tamayo Cardona, Julián Andrés.
  • García Zúñiga, Paola; Universidad Antonio Nariño. Facultad de Odontologia. Palmira. CO
  • Ortega Palomino, Juan Pablo; Universidad Antonio Nariño. Facultad de Odontologia. Palmira. CO
  • García Orozco, Stephania; Universidad Antonio Nariño. Facultad de Odontologia. Palmira. CO
  • Pérez Jaramillo, Adolfo; Universidad Antonio Nariño. Facultad de Odontologia. Palmira. CO
  • Tamayo Cardona, Julián Andrés; Universidad Antonio Nariño. Facultad de Odontologia. Palmira. CO
Rev. cuba. estomatol ; 56(3): e1420, jul.-set. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1093233
RESUMEN
RESUMEN

Introducción:

Los cementos selladores en endodoncia deben tener estabilidad dimensional para controlar la contaminación por microorganismos.

Objetivo:

Determinar la estabilidad dimensional del cemento endodóntico Adseal® en humedad relativa.

Métodos:

se realizó un estudio in vitro, mediante las especificaciones de la Organización Internacional de Normalización (ISO) 68762001. Se emplearon cinco moldes cilíndricos, los cementos fueron sometidos a humedad relativa, se utilizaron dos gabinetes para mantener la temperatura de 37° ± 1 ºC, monitoreados con un termohigrómetro. Se utilizó el estereomicroscopio para la medición en la 1ra, 2da, 3ra y 4ta semanas. Se utilizó la prueba de Friedman para evaluar la estabilidad dimensional; el nivel de significancia fue del 5 por ciento.

Resultados:

el Adseal® en humedad relativa en la 1ra semana registró una expansión leve 0,07 por ciento (11 024,2 µm), en la 2da semana presentó una leve contracción -0,06 por ciento (11 009,2 µm), en la 3ra y 4ta semanas se registró una mayor expansión de longitud por encima de la norma ISO de 1,46 por ciento (11177,4 µm) y 2,76 % (11 320,6 µm), respectivamente, lo cual resultó estadísticamente significativo durante el periodo de exposición (p= 0,003). Para el diámetro y el perímetro se presentó un aumento por encima del 1 por ciento a la primera y cuarta semanas.

Conclusiones:

Existen cambios dimensionales en expansión de longitud en el cemento Adseal® en las primeras cuatro semanas en humedad relativa, con mayores cambios por encima de la norma en la 3ra y 4ta semanas. Para el diámetro y el perímetro se presentó un aumento por encima de la norma a la 1ra y 4ta semanas(AU)
ABSTRACT
ABSTRACT

Introduction:

Endodontic sealing cements should have dimensional stability to control contamination by microorganisms.

Objective:

Determine the dimensional stability of endodontic cement Adseal® under relative humidity conditions.

Methods:

An in vitro study was conducted based on International Organization for Standardization specifications (ISO) 68762001. Five cylindrical molds were used. The cements were subjected to relative humidity conditions and two cabinets were used to keep the temperature at 37 °C ± 1 ºC, monitored with a thermo-hygrograph. Measurements were taken in the 1st, 2nd, 3rd and 4th weeks with a stereo microscope. The Friedman test was used to evaluate dimensional stability with a significance level of 5 percent.

Results:

Under relative humidity conditions, Adseal® displayed a slight 0.07 percent (11 024.2 µm) expansion the first week, a slight -0.06 percent (11 009.2 µm) contraction the second week, and greater length expansion above the ISO standard of 1.46 percent (11 177.4 µm) and 2.76 percent (11 320.6 µm), respectively, in the third and fourth weeks, which was statistically significant during the exposure period (p= 0.003). Regarding diameter and perimeter, an increase above 1 percent occurred in the first and fourth weeks.

Conclusions:

Length expansion dimensional changes were registered for Adseal® cement during the first four weeks under relative humidity conditions, with greater changes above the standard in the third and fourth weeks. Regarding diameter and perimeter, an increase above the standard occurred in the first and fourth weeks(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Dental Cements / Chemical Phenomena Limits: Humans Language: Spanish Journal: Rev. cuba. estomatol Journal subject: Dentistry Year: 2019 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad Antonio Nariño/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Dental Cements / Chemical Phenomena Limits: Humans Language: Spanish Journal: Rev. cuba. estomatol Journal subject: Dentistry Year: 2019 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad Antonio Nariño/CO