RESUMEN

Introducción:

La aplicación del método de la matriz de riesgo para la evaluación del riesgo radiológico en la medicina permite identificar de manera proactiva debilidades en las etapas del proceso y hacer un plan de acciones de mejora para la seguridad y calidad.

Objetivo:

Evaluar los riesgos radiológicos de la radiosinoviortesis y el tratamiento mielosupresor con Fósforo-32 de la policitemia vera.

Método:

Se utilizó el método de matriz de riesgo y se realizó el análisis y tratamiento de los riesgos radiológicos por medio del código cubano SECURE-MR-FMEA 3.0.

Resultados:

El 17 por ciento del riesgo alto se eliminó con las medidas adicionales adoptadas; predominaron las consecuencias medias para los trabajadores y el público, 30 por ciento y el 14 por ciento, respectivamente. Las defensas más importantes fueron levantamiento radiológico inicial de las áreas del departamento; revisión independiente del proyecto con las regulaciones de seguridad aplicables; inspección de trabajos de construcción civil y montaje de equipos antes de iniciar la operación del departamento; capacitación de los médicos nucleares en los tratamientos; existencia de protocolos de tratamiento; análisis de lecciones aprendidas de incidentes radiológicos; levantamiento radiológico periódico de las áreas del servicio y procedimiento de emergencia para reducir la dosis en órganos críticos en caso de administración errónea de radiofármacos. Se creó una base de datos de incidentes utilizada como referencia para el modelo utilizado. El factor humano fue la causa mayor de los sucesos radiológicos analizados (88 por ciento).

Conclusiones:

Estos resultados facilitan la toma de decisiones para el mejor desempeño de la radiosinoviortesis y el tratamiento de la policitemia vera con Fósforo-32 en Cuba. Se sugiere elaborar el plan de mejora de la seguridad con especial atención a las operaciones de administración del radiofármaco en ambos casos.(AU)
ABSTRACT

Introduction:

The application of risk matrix for ionizing radiation medicine allow identify in proactive way the weakness of the process' step, which implies in the design of safety and quality improvement plan for this.

Method:

Risk matrix method applied for radiosynoviorthesis and the myelosupressor treatment with Phosphorus-32 of polycythemia vera. The Cuban code SECURE-MR-FMEA 3.0 is used.

Results:

It was eliminated the 17 percent of the high risk with additional measures, and the medium consequences for workers and public are 30 percent and 14 percent, respectively. The most important identified safety measures were the initial radiological monitoring from different nuclear medicine department areas; the project revision based on the applicable safety regulations; a survey of civil construction works and equipment assembly before work began; training of nuclear medicine doctors in related aspects of nuclear medicine treatments; existence of treatment protocols; the analysis of learned lessons from radiological incidents; the periodical radiological monitoring from different services areas and the emergency procedure for the cases of mistake in the radiopharmaceuticals administration. Human factor was the major cause in analyzed radiological events (88 percent).

Conclusions:

These results facilitate taking decisions for the best performance of radiosynoviorthesis and the myelosupressor treatment with Phosphorus-32 of polycythemia vera in Cuba. It is recommended to elaborate the safety improvement plan from these and focussing in the radiopharmaceutical administration operations in both cases.(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Phosphorus / Polycythemia Vera Type of study: Etiology study / Practice guideline / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2019 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro de Isótopos (CENTIS)/CU / Instituto de Hematología e Inmunología/CU / Universidad de La Habana/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Phosphorus / Polycythemia Vera Type of study: Etiology study / Practice guideline / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2019 Type: Article Affiliation country: Cuba Institution/Affiliation country: Centro de Isótopos (CENTIS)/CU / Instituto de Hematología e Inmunología/CU / Universidad de La Habana/CU