Your browser doesn't support javascript.
loading
Evaluación de la Saturación Venosa de Oxígeno (SvO2) desde la teoría de los sistemas dinámicos / Evaluation of SvO2 from the Theory of Dynamic Systems
Aragón Daza, María Laura; Rodríguez Velásquez, Javier Oswaldo; Prieto Bohórquez, Signed Esperanza; Correa Herrera, Sandra Catalina; Oliveros Rodríguez, Henry; Soracipa Muñoz, María Yolanda; Bermúdez Narváez, Luis Eduardo; Pardo Oviedo, Juan Mauricio; Rubio Martínez, Juan Carlos; Ortiz Salamanca, Liliana Astrid.
  • Aragón Daza, María Laura; Universidad Militar Nueva Granada-Centro de Investigaciones Clínica del Country. Bogotá. CO
  • Rodríguez Velásquez, Javier Oswaldo; Universidad Militar Nueva Granada. Centro de Investigaciones Clínica del Country. Grupo Insight. Bogotá. CO
  • Prieto Bohórquez, Signed Esperanza; Universidad Militar Nueva Granada. Centro de Investigaciones Clínica del Country. Grupo Insight. Bogotá. CO
  • Correa Herrera, Sandra Catalina; Centro de Investigaciones Clínica del Country. Grupo Insight. Bogotá. CO
  • Oliveros Rodríguez, Henry; Universidad Militar Nueva Granada. Unidad de Cuidados Posquirúrgicos-Hospital Militar Central. Bogotá. CO
  • Soracipa Muñoz, María Yolanda; Centro de Investigaciones Clínica del Country. Grupo Insight. Bogotá. CO
  • Bermúdez Narváez, Luis Eduardo; Grupo Insight. Bogotá. CO
  • Pardo Oviedo, Juan Mauricio; Hospital Universitario Mayor Mederi. Bogotá. CO
  • Rubio Martínez, Juan Carlos; Grupo Insight. Bogotá. CO
  • Ortiz Salamanca, Liliana Astrid; Centro de Investigaciones Clínica del Country. Grupo Insight. Bogotá. CO
Rev. cuba. inform. méd ; 11(2)jul.-dic. 2019. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1093317
RESUMEN

Introducción:

La evolución de un sistema dinámico se puede caracterizar a partir de la construcción de atractores caóticos.

Objetivo:

Desarrollar una metodología de evaluación de la saturación venosa de oxígeno, fundamentada en los sistemas dinámicos, para pacientes en Unidad de Cuidados Intensivos.

Metodología:

Se seleccionaron 10 pacientes con diferentes patologías de la Unidad de Cuidados Intensivos Postquirúrgicos, y registró la saturación venosa de oxígeno durante su tiempo de estancia. Con base en estos valores se construyeron atractores caóticos en el mapa de retardo y se evaluaron los valores mínimos y máximos ocupados por el atractor.

Resultados:

Se halló que la saturación venosa de oxígeno tiene un comportamiento caótico; los valores máximos y mínimos de los atractores en el mapa de retardo variaron entre 22,10 mmHg y 93,70 mmHg.

Conclusiones:

Se plantea una nueva metodología capaz de caracterizar el comportamiento de la variable monitorizada para la evaluación del paciente crítico(AU)
ABSTRACT

Introduction:

The evolution of a dynamic system can be characterized from the construction of chaotic attractors.

Objective:

To develop a methodology based on dynamic systems, for the evaluation of venous oxygen saturation of patients in the Intensive Care Unit.

Methodology:

10 patients with different pathologies of the Post-surgical Intensive Care Unit were selected, and recorded venous oxygen saturation during their time of stay. Based on these values, chaotic attractors were constructed on the delay map and the minimum and maximum values occupied by the attractor were evaluated.

Results:

It was found that venous oxygen saturation has a chaotic behavior; the maximum and minimum values of the attractors on the delay map varied between 22.10 mmHg and 93.70 mmHg.

Conclusions:

A new methodology is proposed capable of characterizing the behavior of this monitored variable for the evaluation of the critical patient(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Oximetry / Fractals / Critical Care / Models, Theoretical Type of study: Prognostic study Limits: Female / Humans / Male Country/Region as subject: South America / Colombia Language: Spanish Journal: Rev. cuba. inform. méd Journal subject: Medical Informatics / Health Services Year: 2019 Type: Article Affiliation country: Colombia Institution/Affiliation country: Grupo Insight/CO / Hospital Universitario Mayor Mederi/CO / Universidad Militar Nueva Granada/CO / Universidad Militar Nueva Granada-Centro de Investigaciones Clínica del Country/CO

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Oximetry / Fractals / Critical Care / Models, Theoretical Type of study: Prognostic study Limits: Female / Humans / Male Country/Region as subject: South America / Colombia Language: Spanish Journal: Rev. cuba. inform. méd Journal subject: Medical Informatics / Health Services Year: 2019 Type: Article Affiliation country: Colombia Institution/Affiliation country: Grupo Insight/CO / Hospital Universitario Mayor Mederi/CO / Universidad Militar Nueva Granada/CO / Universidad Militar Nueva Granada-Centro de Investigaciones Clínica del Country/CO