Objetivo:
Comunicar los resultados clínicos y radiológicos a mediano plazo de 34 artroplastias totales de rodilla abisagradas rotatorias. Materiales yMétodos:
Se evaluó a un grupo de 34 prótesis abisagradas de rodilla. Se indicó una bisagra a 10 pacientes (29,5%) sometidos a una cirugía primaria y a 24 (70,5%), a una cirugía de revisión. La edad promedio de la serie era de 78.5 años (rango 54-85).Resultados:
El seguimiento promedio fue de 6.5 años (rango 2-12). El rango de movilidad conseguido fue 110° de flexión (rango 70-130°) y 5° de extensión (rango 0-20°). El puntaje promedio en el KSS mejoró de 38 antes de la cirugía a 82 en el posoperatorio. En la evaluación radiológica, se detectaron líneas radiolúcidas >2 mm alrededor del componente femoral o tibial, o alrededor de los vástagos, en 8 casos (23%). Cinco de 34 pacientes (14,7%) sufrieron complicaciones. En tres casos (8,9%), se trató de una infección profunda. Dos pacientes (5,9%) tuvieron complicaciones rotulofemorales. La supervivencia de la prótesis libre de revisión a los 6.5 años fue del 94%. Si consideramos el aflojamiento aséptico como causa de revisión, la supervivencia fue del 100%.Conclusiones:
Las prótesis abisagradas rotatorias de rodilla modernas logran buenos resultados funcionales y de alivio del dolor. También se asocian a bajas tasas de aflojamiento aséptico a mediano plazo. Sin embargo, las complicaciones sépticas son frecuentes. Nivel de Evidencia IVABSTRACT
Objective:
To analyze the clinical and radiological mid-term outcomes of 34 rotating-hinge total knee arthroplasties. Materials andMethods:
We studied 34 hinge knee prostheses. The arthroplasty indication was in the setting of primary surgery for 10 patients (29.5%) and in the setting of revision for 24 patients (70.5%). The overall average age was 78.5 years (range, 54-85 years).Results:
The average follow-up was 6.5 months (range, 2-12). The achieved range of motion (ROM) was 110° of flexion (range, 70°-130°) and 5° of extension (range, 0°-20°). The average Knee Society Score (KSS) improved from 38 in the preoperative period to 82 in the postoperative period. Radiolucent lines (>2 mm) around the femoral or tibial components or around the stems were observed in 8 patients (23%). Five out of 34 patients (14.7%) developed complications. Three patients (8.9%) developed a deep infection. Two patients (5.9%) developed patellofemoral complications. Prosthesis survivorship without revision was 94% at 6.5 years. And, considering aseptic loosening as a revision cause, prosthesis survivorship was 100%.Conclusion:
Modern rotatinghinge knee prostheses provide good outcomes in terms of function and pain relief. They also provide a low rate of aseptic loosening at mid-term follow-up. However, deep infection and septic loosening are common. Level of Evidence IV
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Prosthesis Design
/
Reoperation
/
Follow-Up Studies
/
Range of Motion, Articular
/
Treatment Outcome
/
Arthroplasty, Replacement, Knee
/
Knee Joint
Type of study:
Observational study
/
Prognostic study
Limits:
Aged
Language:
Spanish
Journal:
Rev. Asoc. Argent. Ortop. Traumatol
Journal subject:
Orthopedics
Year:
2020
Type:
Article
Affiliation country:
Argentina
/
Brazil
Institution/Affiliation country:
Hospital Provincial de Neuquén/AR
/
Hospital Sirio Libanés/AR
Similar
MEDLINE
...
LILACS
LIS