RESUMEN
Introducción: El diagnóstico del embarazo ectópico puede no resultar fácil y se debe realizar con rapidez y seguridad, pues una demora puede conllevar a la ruptura, la hemorragia y poner en peligro la vida de la paciente. Objetivo: Determinar el grado de correlación de valores de β-hCG y ultrasonografía con los hallazgos intra-operatorios de pacientes con diagnóstico de embarazo ectópico en el servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés. Material y métodos: Estudio descriptivo transversal y retrospectivo. Se estudiaron 115 pacientes con diagnóstico de embarazo ectópico, internadas en el Servicio de Ginecología y Obstetricia del Hospital Municipal Boliviano Holandés, durante el periodo 2010 - 2014. Resultados: La población con mayor frecuencia afectada, es de 20 a 30 años de edad (88,7%). La mayor cantidad de población, se observó durante el año 2014 (47%). La validez de los hallazgos ultrasonográficos es de: Sensibilidad = 98,2% y Especificidad = 75%. La seguridad de los hallazgos ultrasonográficos es de: Valor Predictivo Positivo = 99,1% y Valor Predictivo Negativo = 60%. La validez de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Sensibilidad = 99,1% y Especificidad = 100%. La seguridad de los hallazgos ultrasonográficos combinado con la cuantificación sérica de β-hCG es de: Valor Predictivo Positivo = 100% y Valor Predictivo Negativo = 80%. Conclusión: El test diagnóstico ultrasonográfico combinado con la cuantificación sérica de β-hCG tiene mayor validez y seguridad que el test diagnóstico ultrasonográfico solo.
ABSTRACT
Introduction: The diagnosis for ectopic pregnancy may be difficult, and must be carried out quickly and safely since a delay can lead to rupture, bleeding and endanger the life of the patient. Objective: To determine the correlation degree of β-hCG levels and ultrasonography with the intra-operative findings of patients with ectopic pregnancy diagnosis in the Gynecology and Obstetrics Service at Hospital Municipal Boliviano Holandés. Material and methods: Descriptive, cross-sectional and retrospective study that included 115 patients with ectopic pregnancy diagnosis, and admitted in the Obstetrics and Gynecology Service at Hospital Municipal Boliviano Holandés during the period 2010-2014. Results: The most frequently affected population was 20 to 30 years old (88.7%). Most of the cases were observed during 2014 (47%). Validity of ultrasound findings reflected 98.2% of sensitivity and 75 % of specificity. Safety of ultrasound findings reflected Positive Predictive Value of 99.1 % and Negative Predictive Value of 60 %. Validity of ultrasound findings combined with β-hCG serum quantification displayed a sensitivity of 99.1 % and specificity of100%. Safety of ultrasound findings combined with β-hCG serum quantification displayed a Positive Predictive Value of 100 % and Negative Predictive Value of 80 %. Conclusions: The ultrasonographic diagnostic test combined with the β-hCG serum quantification has better validity and safety than the ultrasonographic test alone.
Full text:
Available
Index:
LILACS (Americas)
Main subject:
Pregnancy, Ectopic
Type of study:
Observational study
/
Prognostic study
/
Risk factors
Language:
Spanish
Journal:
Rev. méd. (La Paz)
Journal subject:
Medicine
Year:
2020
Type:
Article
Affiliation country:
Bolivia
Institution/Affiliation country:
Hospital Municipal Boliviano Holandés/BO
/
Hospital del Norte/BO
Similar
MEDLINE
...
LILACS
LIS