Your browser doesn't support javascript.
loading
Contaminación ambiental por microorganismos multirresistentes y el efecto de la limpieza y desinfección en una unidad de cuidados intensivos / Environmental contamination by multi-resistant microorganisms and the effect of cleaning and disinfection in an intensive care unit / Contaminação ambiental por micro-organismos multirresistentes e o efeito de limpeza e desinfecção em unidade de terapia intensiva
Yiyela Masó, Marina; Sesma, Ana Claudia; Pintado, Sandra; Santolin, Carolina; Luna, Tomás Ignacio; Mangiaterra, Sandra Mariela.
  • Yiyela Masó, Marina; Hospital Italiano. Servicio de Laboratorio. área de Bacteriología. Córdoba. AR
  • Sesma, Ana Claudia; Hospital Italiano. Servicio de Laboratorio. área de Bacteriología. Córdoba. AR
  • Pintado, Sandra; Hospital Italiano. Servicio de Laboratorio. AR
  • Santolin, Carolina; s.af
  • Luna, Tomás Ignacio; Hospital Italiano. Unidad de Cuidados Intensivos de Adultos. AR
  • Mangiaterra, Sandra Mariela; Hospital Italiano. Servicio de Laboratorio. área de Bacteriología. Córdoba. AR
Acta bioquím. clín. latinoam ; 54(2): 145-150, jun. 2020. tab
Article in Spanish | LILACS | ID: biblio-1130589
RESUMEN
Conocer el rol del medio ambiente es fundamental para evitar las infecciones intra-hospitalarias. Con ese objetivo, se planteó evaluar la prevalencia de contaminación ambiental por microorganismos multirresistentes (MMR) antes y después de la limpieza terminal de habitaciones de pacientes colonizados y establecer si la aparatología de uso común actuaba como reservorio de estos en la unidad de cuidados intensivos (UTI). Se obtuvieron muestras ambientales de las habitaciones, 48 h posteriores a la detección de colonización y luego de las limpiezas. Los resultados mostraron que luego de ambos procedimientos de limpieza se logró reducir de 28,2% a 2,6% la contaminación por Acinetobacter spp. multirresistente (AMR). También, se tomaron muestras de aparatología de uso común encontrándose entre 1,8 y 5,4% de contaminación por MMR. La limpieza y desinfección reducen significativamente la contaminación ambiental. Sin embargo, la colonización de equipos por MMR y el incumplimiento de precauciones universales representan una posibilidad de transmisión cruzada.
ABSTRACT
It is essential to understand the role of the environment in order to avoid intrahospital infections. To achieve this objective, this research proposes to assess the prevalence of the environmental contamination caused by multi-resistant microorganisms (MRM) before and after terminal disinfection in rooms with colonized patients, but also to establish whether the commonly used device acts as a reservoir of those micro-organisms in an intensive care unit (ICU). Environmental samples were obtained from the rooms, 48 hours after detecting colonization and also after the first and second final cleaning. The results showed that after both procedures, there was a reduction from 28.2% to 2.6% of contamination caused by multi-resistant Acinetobacter spp. (AMR). Samples from appliances and supplies were taken as well, in which case, between 1.8 and 5.4% of contamination levels induced by MMR were found. Cleaning and disinfecting significantly reduce environmental contamination. However, both MMR bacterial colonization and the lack of universal precautions enforcement represent a possibility of cross-transmission.
RESUMO
É essencial conhecer o papel do meio ambiente para evitar as infecções intra-hospitalares. Com esse objetivo, planejou-se avaliar a prevalência de contaminação ambiental por microorganismos multirresistentes (MMR) antes e depois da limpeza final dos quartos de pacientes colonizados e estabelecer se os aparelhos de uso comum atuavam como um reservatório deles na unidade de terapia intensiva (UTI). Obtiveram-se amostras ambientais dos quartos 48 horas após a detecção da colonização e logo após as limpezas finais. Os resultados mostraram que depois dos dois procedimentos de limpeza se obteve uma redução de 28,2% para 2,6% da contaminação por Acinetobacter spp. multirresistente (AMR). Foram obtidas também amostras de aparelhos de uso comum onde se encontraram entre 1,8% e 5,4% de contaminação por MMR. A limpeza e a desinfecção reduzem significativamente a contaminação ambiental. Contudo, a colonização de equipamentos por MMR e o não cumprimento de providências universais representam uma possibilidade de transmissão cruzada.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Acinetobacter / Disinfection / Environmental Pollution / Housekeeping, Hospital / Intensive Care Units Type of study: Prevalence study / Risk factors Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2020 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Italiano/AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Acinetobacter / Disinfection / Environmental Pollution / Housekeeping, Hospital / Intensive Care Units Type of study: Prevalence study / Risk factors Limits: Humans Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2020 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital Italiano/AR