Your browser doesn't support javascript.
loading
Discordância entre Diretrizes Internacionais sobre Critérios de Prevenção Primária de Morte Súbita na Cardiomiopatia Hipertrófica / Discrepancy between International Guidelines on the Criteria for Primary Prevention of Sudden Cardiac Death in Hypertrophic Cardiomyopathy
Mattos, Beatriz Piva e; Scolari, Fernando Luís; Garbin, Henrique Iahnke.
  • Mattos, Beatriz Piva e; Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Scolari, Fernando Luís; Hospital de Clínicas de Porto Alegre. Porto Alegre. BR
  • Garbin, Henrique Iahnke; Universidade Federal do Rio Grande do Sul. Faculdade de Medicina. Porto Alegre. BR
Arq. bras. cardiol ; 115(2): 197-204, ago., 2020. tab, graf
Article in English, Portuguese | LILACS, SES-SP | ID: biblio-1131297
RESUMO
Resumo Fundamento A estratificação de risco para morte súbita (MS) na cardiomiopatia hipertrófica (CMH) baseia-se em algoritmos distintos propostos pela diretriz norte-americana, ACCF/AHA 2011 e europeia, ESC 2014. Objetivo Analisar o modelo ESC 2014 na determinação do risco de MS e indicação de cardiodesfibrilador implantável (CDI) em prevenção primária na CMH por meio de confrontação com a normativa norte-americana. Métodos Foi avaliada uma coorte de pacientes com CMH, calculado o escore ESC HCM-Risk-SCD e analisada a concordância dos critérios de indicação de CDI entre as duas diretrizes pelo coeficiente de Kappa. O nível de significância adotado nas análises estatísticas foi de 5%. Resultados Em 90 pacientes consecutivos, seguidos por 6±3 anos, o escore calculado foi de 3,2±2,5%. Os preditores que mais contribuíram para o cálculo nas faixas de baixo (1,88% [1,42-2,67]), médio (5,17% [4,89-5,70]) e alto risco (7,82% [7,06-9,19]) foram espessura parietal máxima do ventrículo esquerdo (1,60% [1,25-2,02] ; 3,20% [3,18-3,36] ; 4,46% [4,07-5,09]), diâmetro do átrio esquerdo (0,97% [0,83-1,21]; 1,86% [1,67-2,40]; 2,48% [2,21-3,51]) e idade (-0,91% [0,8-1,13]; -1,90% [1,12-2,03]; -2,34% [1,49-2,73]). O modelo europeu reduziu as recomendações de CDI em 32 (36%) pacientes. Entre os 43 (48%) em classe IIa pela ACCF/AHA , 8 (18%) migraram para IIb e 24 (56%) para III. Baixa concordância foi identificada entre as duas sistematizações, Kappa = 0,355, p = 0,0001. Dos 8 (9%) pacientes com MS ou choque apropriado, 4 (50%) atingiram indicação IIa pela ACCF/AHA , mas nenhum pela ESC . Conclusão Baixa concordância foi identificada entre as diretrizes analisadas. O novo modelo reduziu as indicações de CDI, notadamente em classe IIa, mas deixou desprotegida a totalidade de pacientes com MS ou choque apropriado. (Arq Bras Cardiol. 2020; 115(2)197-204)
ABSTRACT
Abstract Background Risk stratification for sudden cardiac death (SCD) in hypertrophic cardiomyopathy (HCM) is based on different algorithms proposed by the 2011 ACCF/AHA and 2014 ESC guidelines. Objective To analyze the 2014 ESC model for SCD risk stratification and primary prevention ICD (implantable cardioverter defibrillator) in HCM in comparison to the North American guideline. Methods An HCM cohort was evaluated and the ESC HCM-Risk SCD score was calculated. Agreement of ICD recommendations criteria between the two guidelines was analyzed with Kappa coefficient. P<0.05 was adopted for the statistical analysis. Results In 90 consecutive patients followed for 6±3 years, the mean calculated ESC risk score was 3.2±2.5%. The risk predictors that have mainly contributed to the score calculation in the low (1.88% [1.42-2.67]), intermediate (5.17% [4.89-5.70]) and high-risk (7.82% [7.06-9.19]) categories were maximal left ventricular wall thickness (1.60% [1.25-2.02]; 3.20% [3.18-3.36]; 4.46% [4.07-5.09]), left atrial diameter (0.97% [0.83-1.21]; 1.86% [1.67-2.40]; 2.48% [2.21-3.51]) and age (-0.91% [0.8-1.13]; -1.90% [1.12-2.03]; -2.34% [1.49-2.73]). The European model decreased the ICD recommendations in 32 (36%) patients. Among the 43 (48%) individuals with class IIa recommendation under the 2011 ACCF/AHA guideline, 8 (18%) were downgraded to class IIb and 24 (56%) to class III. Low agreement was found between the two systems Kappa=0.355 and p=0.0001. In 8 (9%) patients with SCD or appropriate shock, 4 (50%) met class IIa indication with the 2011 ACCF/AHA guideline, but none achieved this class of recommendation with the 2014 ESC model. Conclusion Low agreement was found between the two strategies. The novel ESC model decreased the ICD recommendations, especially in those with class IIa recommendation, but left unprotected all patients with SCD or appropriate shock. (Arq Bras Cardiol. 2020; 115(2)197-204)
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Cardiomyopathy, Hypertrophic / Defibrillators, Implantable Type of study: Etiology study / Practice guideline / Prognostic study / Risk factors Limits: Humans Language: English / Portuguese Journal: Arq. bras. cardiol Year: 2020 Type: Article Institution/Affiliation country: Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Cardiomyopathy, Hypertrophic / Defibrillators, Implantable Type of study: Etiology study / Practice guideline / Prognostic study / Risk factors Limits: Humans Language: English / Portuguese Journal: Arq. bras. cardiol Year: 2020 Type: Article Institution/Affiliation country: Hospital de Clínicas de Porto Alegre/BR / Universidade Federal do Rio Grande do Sul/BR