Teste de apneia para diagnóstico de morte encefálica em adultos sob oxigenação por membrana extracorpórea: revisão / Apnea test for brain death diagnosis in adults on extracorporeal membrane oxygenation: a review
Sady, Erica Regina Ribeiro; Junqueira, Lígia; Veiga, Viviane Cordeiro; Rojas, Salomón Soriano Ordinola.
  • Sady, Erica Regina Ribeiro; Hospital Beneficência Portuguesa. Unidade de Terapia Intensiva Neurológica. São Paulo. BR
  • Junqueira, Lígia; Hospital Beneficência Portuguesa. Unidade de Terapia Intensiva Neurológica. São Paulo. BR
  • Veiga, Viviane Cordeiro; Hospital Beneficência Portuguesa. Unidade de Terapia Intensiva Neurológica. São Paulo. BR
  • Rojas, Salomón Soriano Ordinola; Hospital Beneficência Portuguesa. Unidade de Terapia Intensiva Neurológica. São Paulo. BR
Rev. bras. ter. intensiva ; 32(2): 312-318, Apr.-June 2020. graf
Article in English, Portuguese | LILACS | ID: biblio-1138488
RESUMO
RESUMO Entre as potenciais complicações da oxigenação por membrana extracorpórea, as disfunções neurológicas, incluindo morte encefálica, não são desprezíveis. No Brasil, o processo diagnóstico é regulamentado pela resolução 2.173 de 2017 do Conselho Federal de Medicina. Entre os testes diagnósticos, está o de apneia, que objetiva verificar se existe resposta ventilatória ao estímulo hipercápnico. Contudo, trocas gasosas, incluindo a remoção de dióxido de carbono, são mantidas sob oxigenação por membrana extracorpórea, tornando o teste desafiador. Somado ao fato de que a citada resolução não contempla as especificidades do processo diagnóstico sob oxigenação por membrana extracorpórea, publicações sobre o tema são escassas. Esta revisão objetivou identificar estudos de casos (e/ou séries de casos) publicados nas bases PubMed® e Cochrane que descrevessem o processo. Foram identificadas 17 publicações (2011 - 2019). As estratégias práticas descritas foram prover oxigenação suplementar pré-teste, via ventilador mecânico e oxigenação por membrana extracorpórea (fração inspirada de oxigênio = 1,0), e, ao início do teste, titular o sweep flow (0,5 - 1,0L/minuto), a fim de minimizar a remoção de dióxido de carbono. Recomenda-se também incrementar o fluxo sanguíneo e/ou do sweep ante hipoxemia e/ou hipotensão, podendo associar à infusão de fluidos e/ou ao escalonamento de drogas inotrópicas/vasoativas. Se o limiar da pressão parcial de dióxido de carbono não for alcançado, repetir o teste sob suplementação de dióxido de carbono exógeno ao circuito é uma alternativa. Finalmente, nos casos de oxigenação por membrana extracorpórea venoarterial, para mensurar a variação de gases e excluir hipóxia diferencial, recomenda-se coletar amostras sanguíneas provenientes das circulações nativa e extracorpórea (pós-oxigenador).
ABSTRACT
Abstract Among the potential complications of extracorporeal membrane oxygenation, neurological dysfunctions, including brain death, are not negligible. In Brazil, the diagnostic process of brain death is regulated by Federal Council of Medicine resolution 2,173 of 2017. Diagnostic tests for brain death include the apnea test, which assesses the presence of a ventilatory response to hypercapnic stimulus. However, gas exchange, including carbon dioxide removal, is maintained under extracorporeal membrane oxygenation, making the test challenging. In addition to the fact that the aforementioned resolution does not consider the specificities of the diagnostic process under extracorporeal membrane oxygenation, studies on the subject are scarce. This review aims to identify case studies (and/or case series) published in the PubMed® and Cochrane databases describing the process of brain death diagnosis. A total of 17 publications (2011 - 2019) were identified. The practical strategies described were to provide pretest supplemental oxygenation via mechanical ventilation and extracorporeal membrane oxygenation (fraction of inspired oxygen = 1.0) and, at the beginning of the test, titrate the sweep flow (0.5 - 1.0L/minute) to minimize carbon dioxide removal. It is also recommended to increase blood flow and/or sweep flow in the presence of hypoxemia and/or hypotension, which may be combined with fluid infusion and/or the escalation of inotropic/vasoactive drugs. If the partial pressure of carbon dioxide threshold is not reached, repeating the test under supplementation of carbon dioxide exogenous to the circuit is an alternative. Last, in cases of venoarterial extracorporeal membrane oxygenation, to measure gas variation and exclude differential hypoxia, blood samples of the native and extracorporeal (post-oxygenator) circulations are recommended.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Apnea / Brain Death / Extracorporeal Membrane Oxygenation Type of study: Diagnostic study / Prognostic study Limits: Adult / Humans Country/Region as subject: South America / Brazil Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2020 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Beneficência Portuguesa/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Apnea / Brain Death / Extracorporeal Membrane Oxygenation Type of study: Diagnostic study / Prognostic study Limits: Adult / Humans Country/Region as subject: South America / Brazil Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2020 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Beneficência Portuguesa/BR