Your browser doesn't support javascript.
loading
Avaliação da interface entre o componente protético reto e a conexão interna tipo Cone Morse do implante dentário por meio da microscopia eletrônica de varredura / Evaluation of the interface between the straight prosthetic component and the Morse Cone-type internal connection of the dental implant in cross section by scanning electron microscopy
Costa, Mariana Bispo; Ferreira, Lorena Fernandes; Takeshita, Wilton Mitsunari; Marqueti, Antonio Carlos; Trento, Cleverson Luciano.
  • Costa, Mariana Bispo; Universidade Federal de Sergipe. Aracaju. BR
  • Ferreira, Lorena Fernandes; Universidade Federal de Sergipe. Aracaju. BR
  • Takeshita, Wilton Mitsunari; Universidade Federal de Sergipe. Aracaju. BR
  • Marqueti, Antonio Carlos; Universidade Federal de Sergipe. Aracaju. BR
  • Trento, Cleverson Luciano; Universidade Federal de Sergipe. Aracaju. BR
Rev. odontol. UNESP (Online) ; 49: e20200033, 2020. tab, ilus
Article in Portuguese | LILACS, BBO | ID: biblio-1139420
RESUMO
Resumo Introdução A interface implante-pilar protético e a formação dos seus microgaps são aspectos relevantes na transferência das cargas e na resposta biológica, estando ligadas ao sucesso da reabilitação. Objetivo Avaliar microgaps na interface entre a conexão interna do implante do tipo Cone Morse e a superfície do componente protético por meio da microscopia eletrônica de varredura (MEV). Material e método Foram utilizados 20 implantes dentários de tamanho 3,75 × 11,0mm do tipo Cone Morse com seus respectivos pilares protéticos da Singular® (Singular Implants, RN, Brasil). Os munhões retos foram acoplados aos implantes com torque de 32N/cm2 e o conjunto resultante foi emergido em base de Resina Epóxi ES260, para permitir secção longitudinal da amostra. As amostras foram analisadas e os microgaps mensurados no MEV (JEOL JCM-5700, MA, USA), e posteriormente os dados foram analisados. Resultado A média e o desvio padrão dos maiores microgaps foram observados na parte apical do implante nos lados direito e esquerdo, sendo 1,44±2,68 e 1,16±1,49 μm, respectivamente. Os menores microgaps foram na parte superior do implante nos lados direito e esquerdo, sendo 0,60±0,73 e 0,66±0,67 μm, respectivamente. Contudo, no teste de Kruskal-Wallis, não houve diferença estatisticamente significativa entre as regiões dos implantes, tanto para o lado esquerdo (p=0,692) como para o direito (p=0,865). No teste de Mann-Whitney, não houve diferenças estatisticamente significativas entre os lados para as diferentes regiões dos implantes. Conclusão Mesmo com a presença de microgaps na interface implante-pilar protético, estes apresentam tamanho inferior ao que causaria problemas biológicos e mecânicos. As amostras analisadas quanto à sua compatibilidade de encaixe foram satisfatórias.
ABSTRACT
Abstract Introduction The implant-prosthetic abutment interface and the formation of its microgaps are relevant aspects in load transfer and biological response and are linked to the success of the rehabilitation. Objective To evaluate microgaps at the internal connection interface of the Cone Morse implant and the prosthetic component surface by means of scanning electron microscopy (SEM). Material and method Twenty 3.75 x 11.0 mm Cone Morse dental implants with their respective Singular® prosthetic abutments were used (Singular Implants, RN, Brazil). The straight trunnions were attached to the implants with a 32N/cm2 torque and the ES260 Epoxy Resin-based set emerged to allow longitudinal sectioning of the sample. The samples were analyzed and the microgaps measured in SEM (JEOL JCM-5700, MA, USA), and later the data were analyzed. Result The mean and standard deviation of the largest microgaps were observed in the apical part of the right and left side 1.44±2.68 and 1.16±1.49 μm, respectively. The smallest microgaps were on the upper implant right and left sides 0.60±0.73 and 0.66±0.67 μm, respectively. However, in the Kruskal-Wallis test there was no statistically significant difference between the implant regions, both for the left side (p=0.692) and right side (p=0.865). The Mann-Whitney test, there were no statistically significant differences between the sides for the different regions of the implants. Conclusion Even with the presence of microgaps in the implant-post interface, it presents a smaller size than the one presenting biological and mechanical problems. The samples analyzed for their fitting compatibility were satisfactory.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Microscopy, Electron, Scanning / Statistics, Nonparametric / Dental Implantation Language: Portuguese Journal: Rev. odontol. UNESP (Online) Journal subject: Dentistry Year: 2020 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Sergipe/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Microscopy, Electron, Scanning / Statistics, Nonparametric / Dental Implantation Language: Portuguese Journal: Rev. odontol. UNESP (Online) Journal subject: Dentistry Year: 2020 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Sergipe/BR