Your browser doesn't support javascript.
loading
Estudio de bioequivalencia in vitro de comprimidos de liberación inmediata de metformina de 850 mg comercializados en Bolivia / In vitro bioequivalence study of immediate release tablets of 850 mg of metformin marketed in Bolivia
Saravia Gutierrez, Giovana Ximena; Daza Calderón, María Luisa.
Affiliation
  • Saravia Gutierrez, Giovana Ximena; Universidad Mayor de San Andrés. Facultad de Ciencias Farmacéuticas y Bioquímicas. La Paz. BO
  • Daza Calderón, María Luisa; Universidad Mayor de San Andrés. Facultad de Ciencias Farmacéuticas y Bioquímicas. La Paz. BO
Con-ciencia (La Paz) ; 8(2): 75-87, 2020. ilus.
Article in Es | LILACS, LIBOCS | ID: biblio-1148001
Responsible library: BO138.1
RESUMEN

INTRODUCCIÓN:

los estudios de bioequivalencia demuestran la equivalencia en la calidad biofarmacéutica entre el producto farmacéutico multifuente y el medicamento de referencia, permitiendo el establecimiento de puentes entre las pruebas preclínicas y los ensayos clínicos asociados con el medicamento de referencia. La Metformina clorhidrato es el fármaco de primera elección para el tratamiento de la diabetes mellitus II y pertenece a la clase 3 del sistema de clasificación biofarmacéutica.

OBJETIVO:

establecer mediante pruebas de disolución in vitro, si 4 productos farmacéuticos multifuentes de liberación inmediata, de administración peroral, con Metformina clorhidrato, comercializados en Bolivia son bioequivalentes en relación con el producto de referencia, a través de un diseño experimental, con significancia estadística.

MÉTODO:

Se elaboraron perfiles de disolución de cada producto, tomando en cuenta las condiciones del método del ensayo de disolución establecido en la monografía Metformina, tabletas de la USP 39, considerando seis tiempos de muestreo. Se realizó el análisis cinético de los datos de porcentaje disuelto acumulado de los perfiles de disolución versus el tiempo. Se empleó el método de modelo independiente para comparar los perfiles de disolución de los productos a través del cálculo de los factores de diferencia (f1) y de similitud (f2) recomendados para estudios de bioexención por la Organización Mundial de la Salud.

RESULTADOS:

todos los productos tomados en cuenta en la investigación cumplieron satisfactoriamente los análisis de Control de Calidad. Los resultados del estudio de Bioequivalencia mostraron que existen diferencias estadísticamente significativas entre los productos del estudio.

CONCLUSIÓN:

en este estudio no se demostró la Bioequivalencia in vitro de los productos B, C, D y E con relación al producto de referencia A, con base en pruebas de disolución in vitro.
ABSTRACT

INTRODUCTION:

bioequivalence studies demonstrate the equivalence in biopharmaceutical quality between the multi-source pharmaceutical product and the reference medicine, allowing the establishment of bridges between preclinical tests and clinical trials associated with the reference medicine. Metformin hydrochloride is the drug of first choice for the diabetes mellitus II treatment and belongs to class 3 of the Biopharmaceutical Classification System.

OBJECTIVE:

establish by in vitro dissolution tests, whether 4 multisource pharmaceutical products of immediate release and peroral administration, with Metformin hydrochloride, marketed in Bolivia are bioequivalent in relation to the reference product, through an experimental design, with statistical significance.

METHOD:

dissolution profiles were prepared for each product, taking into account the conditions of the dissolution test method established in the Metformin, tablets monograph of USP 39, considering six sampling times. The kinetic analysis of the accumulated dissolved percentage data of the dissolution profiles versus time was performed. The independent model method was used to compare the dissolution profiles of the products by calculating the difference factor (f1) and similarity factor (f2) recommended for Biowaiver studies, by the World Health Organization.

RESULTS:

All the products taken into account in the investigation, satisfactorily fulfilled the Quality Control analysis. The results of the Bioequivalence study showed that there are statistically significant differences between the products of the study.

CONCLUSION:

In this study the in vitro bioequivalence of the products B, C, D and E in relation to the reference product A was not demonstrated, based on in vitro dissolution tests.
Subject(s)
Key words
Full text: 1 Index: LILACS Main subject: Biopharmaceutics / In Vitro Techniques / Metformin Type of study: Prognostic_studies Country/Region as subject: America do sul / Bolivia Language: Es Journal: Con-ciencia (La Paz) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2020 Type: Article
Full text: 1 Index: LILACS Main subject: Biopharmaceutics / In Vitro Techniques / Metformin Type of study: Prognostic_studies Country/Region as subject: America do sul / Bolivia Language: Es Journal: Con-ciencia (La Paz) Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2020 Type: Article