Morbimortalidad cardiovascular y variación del grado funcional en pacientes ancianos portadores de marcapasos / Medium-long term mortality and change in functional status in elderly patients with pacemaker
Pérez-Díaz, Pedro; Jiménez-Díaz, Javier; Higuera-Sobrino, Felipe; Piqueras-Flores, Jesús; Frías-García, Raquel; Mazoteras-Muñoz, Virginia; Maseda-Uriza, Ramón; Arenas-Cambronero, Violeta.
  • Pérez-Díaz, Pedro; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Jiménez-Díaz, Javier; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Higuera-Sobrino, Felipe; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Piqueras-Flores, Jesús; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Frías-García, Raquel; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Mazoteras-Muñoz, Virginia; Servicio de Geriatría; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Maseda-Uriza, Ramón; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
  • Arenas-Cambronero, Violeta; Hospital General Universitario de Ciudad Real HGUCR. Ciudad Real. ES
Arch. cardiol. Méx ; 89(3): 233-241, jul.-sep. 2019. tab, graf
Article in Spanish | LILACS | ID: biblio-1149072
RESUMEN
Resumen Antecedentes Aproximadamente un 49% de los implantes se efectúan a individuos mayores de 80 años; sin embargo, la evidencia científica sobre mortalidad y cambio en la situación funcional de estos pacientes es muy pobre.

Objetivo:

Diseñamos un estudio prospectivo para analizar la morbimortalidad cardiovascular y la variación de su grado funcional a medio plazo en pacientes ancianos con electroestimulación permanente.

Método:

Estudio observacional prospectivo, que incluye 308 pacientes ancianos sometidos a implante de marcapasos en un hospital terciario entre 2012 y 2014. Como variables principales se evaluaron eventos cardiovasculares, mortalidad y grado funcional, con una media de seguimiento de 3.5 años.

Resultados:

El 60% de los pacientes incluidos en nuestro estudio tenían una edad superior a 80 años, y la indicación más frecuente fue el bloqueo auriculoventricular completo (44.3%), seguido de la fibrilación auricular lenta o bloqueada (16.7%). El modo de estimulación más frecuente en la muestra general fue el DDD (38.6%) (VVI en pacientes octogenarios, 38.7%). En el seguimiento, la mortalidad a largo plazo fue mayor en dispositivos ventriculares, especialmente en octogenarios (p = 0.001). El modo de estimulación ventricular (VVI) fue predictor independiente de mortalidad. A largo plazo, no se observó mejoría del índice de Barthel ni del grado funcional tras el implante del marcapasos.

Conclusiones:

La morbimortalidad cardiovascular en pacientes octogenarios portadores de marcapasos resulta superior a la de la población general, especialmente en dispositivos monocamerales. La electroestimulación permanente no se asocia con mejoría del grado funcional a medio-largo plazo en estos pacientes.
ABSTRACT
Abstract

Background:

Nowadays, 49% of patients with pacemakers are older than 80 years old. Nevertheless, mortality and change in functional status after pacemaker implantation are not well documented in elderly patients.

Objective:

We designed a prospective study to analyze cardiovascular mortality and change in functional status of elderly patients, medium-long term after pacemaker implantation.

Methods:

Observational study including pacemaker implants in individual older than 70 years old in a single center university hospital between 2012 and 2014. Analysis testing for an association between pacemaker system, medium-long term mortality and functional status after implantation were undertaken.

Results:

60% of patients were older than 80 years old. Third-degree atrio-ventricular block (44.3%) and slow ventricular response atrial fibrillation (16.7%) were the most frequent electrocardiogram abnormalities, while bicameral DDD was the sort of pacing our department used the most (38.6%) (VVI in octogenarian patients, 38.7%). Long-term mortality was significantly higher in ventricular devices, especially in octogenarian patients (p = 0.001 respectively). Single-chamber VVI pacing acted as independent predictors of all-cause mortality in these individuals (p = 0.001). We found no significant improvement in Barthel index and functional status in this subgroup of patients, 3 years after pacing.

Conclusion:

Long-term mortality in individuals older than 80 years old with pacemaker implantation, was significantly higher comparing with general population, especially in ventricular devices. No significant improvement in functional status was detected in this subgroup of patients.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Atrial Fibrillation / Atrioventricular Block Type of study: Observational study / Prognostic study / Risk factors Limits: Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Arch. cardiol. Méx Journal subject: Cardiology Year: 2019 Type: Article Affiliation country: Spain Institution/Affiliation country: Hospital General Universitario de Ciudad Real HGUCR/ES / Servicio de Geriatría; Hospital General Universitario de Ciudad Real HGUCR/ES

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Pacemaker, Artificial / Atrial Fibrillation / Atrioventricular Block Type of study: Observational study / Prognostic study / Risk factors Limits: Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Arch. cardiol. Méx Journal subject: Cardiology Year: 2019 Type: Article Affiliation country: Spain Institution/Affiliation country: Hospital General Universitario de Ciudad Real HGUCR/ES / Servicio de Geriatría; Hospital General Universitario de Ciudad Real HGUCR/ES