RESUMEN
Objetivo. Comparar el efecto antimicrobiano de la tetraciclina en gel al 2% y de la clorhexidina en gel al 0,12% sobre el biofilm dental de pilares de cicatrización en implantes dentales. Métodos. Estudio experimental en laboratorio, de corte transversal. Se tomaron 25 muestras de biofilm dental presente en los pilares de cicatrización de implantes dentales de la zona en contacto con la mucosa del surco periimplantario de 19 pacientes. Las muestras fueron sembradas en placas Petri con agar Schaedler, a las cuales se les hizo tres pocillos, en uno se colocó tetraciclina en gel al 2%, en otro clorhexidina en gel al 0,12% y en el último agua destilada en cantidades iguales. Las placas Petri fueron incubadas a 37 °C en medio anaerobio por 96 horas luego de los cuales se midieron los halos de inhibición. Resultados. Ambos geles inhibieron el crecimiento de biofilmdental. La tetraciclina en gel al 2% obtuvo mayores diámetros de halos de inhibición que la clorhexidina en gel al 0,12%, con un máximo de 51 mm y 17 mm respectivamente y un mínimo de 21 mm y 10 mm respectivamente, con medias de 35 mm y 12.84 mm respectivamente. Conclusiones. La tetraciclina en gel al 2% tuvo un mayor efecto antimicrobiano en comparación a la clorhexidina en gel al 0,12% sobre el biofilm dental tomado de pilares de cicatrización de implantes dentales.
ABSTRACT
Objective. To compare the antimicrobial effect of 2% tetracycline gel and 0,12% chlorhexidine gel on the dental biofilm of healing abutments on dental implants. Methods.This was an in vitro experimental cross-sectional study. Twenty-five biofilm samples were taken from the dental biofilm present on the area in contact with mucosa and the peri-implant groove of healing abutments of 19 patients. The samples were sowed in Petri dishes with Schaedler agar, three wells were made with a sterile punch and in each one tetracycline 2% in gel, 0,12% chlorhexidine in gel, and distilled water were placed in equal quantities. Then Petri dishes were incubated at 37 °C in an anaerobic medium for 48 hours after which inhibition halos were measured. Results. Both gels were inhibitors of dental biofilm growth. Tetracycline 2% in gel obtained larger diameters of inhibition halos than chlorhexidine 0,12% in gel, with a maximum of 51 mm and 17 mm respectively and a minimum of 21 mm and 10 mm, with means of 35 mm and 12.84 mm respectively. Conclusions. Tetracycline at 2% in gel had a higher antimicrobial effect than 0,12% in gel chlorhexidine on dental biofilm taken from healing abutments of dental implants.
Full text:
1
Index:
LILACS
Type of study:
Observational_studies
/
Prevalence_studies
Language:
Es
Journal:
Odontol. sanmarquina (Impr.)
Journal subject:
Medicina Bucal
/
Odontologia
Year:
2021
Type:
Article