Your browser doesn't support javascript.
loading
Padronizando a Exposição à Radiação durante o Cateterismo Cardíaco em Crianças com Cardiopatia Congênita: Dados de um Registro Multicêntrico Brasileiro / Standardizing Radiation Exposure during Cardiac Catheterization in Children with Congenital Heart Disease: Data from a Multicenter Brazilian Registry
Manica, João Luiz; Duarte, Vanessa Oliveira; Ribeiro, Marcelo; Hartley, Adam; Petraco, Ricardo; Pedra, Carlos; Rossi, Raul.
  • Manica, João Luiz; Fundação Universitária de Cardiologia. Instituto de Cardiologia. Porto Alegre. BR
  • Duarte, Vanessa Oliveira; Fundação Universitária de Cardiologia. Instituto de Cardiologia. Porto Alegre. BR
  • Ribeiro, Marcelo; Hospital do Coração. São Paulo. BR
  • Hartley, Adam; Hammersmith Hospital. Imperial College London. National Heart and Lung Institute. Londres. GB
  • Petraco, Ricardo; Hammersmith Hospital. Imperial College London. National Heart and Lung Institute. Londres. GB
  • Pedra, Carlos; Hospital do Coração. São Paulo. BR
  • Rossi, Raul; Fundação Universitária de Cardiologia. Instituto de Cardiologia. Porto Alegre. BR
Arq. bras. cardiol ; 115(6): 1154-1161, dez. 2020. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1152938
RESUMO
Resumo Fundamento Nos últimos anos, o recente aumento no número de procedimentos intervencionistas tem resultado em crescente preocupação em relação à exposição radiológica por pacientes e equipe médica. A avaliação da exposição dos níveis de radiação em crianças é difícil devido à grande variabilidade no peso corporal. Portanto, os valores de referência de radiação não estão bem definidos para essa população. Objetivos Avaliar e validar a razão do produto dose-área (DAP) em relação ao peso corporal como uma medida de referência de radiação em cateterismos cardíacos em crianças. Métodos Estudo multicêntrico observacional com dados do Registro Brasileiro de Cateterismo Cardíaco em Cardiopatias Congênitas (CHAIN) de março de 2013 a junho de 2014. Os critérios de inclusão foram pacientes <18 anos submetidos a procedimentos hemodinâmicos para cardiopatia congênita, com DAP devidamente registrado. Foram considerados diferenças estatísticas significativas os valores de p < 0,05. Resultados Este estudo avaliou 429 pacientes com idade e peso medianos de 50 (10, 103) meses e 15 (7, 28) kg, respectivamente. O DAP mediano foi de 742,2 (288,8, 1.791,5) μGy.m2. Houve uma boa correlação entre o DAP e o produto peso/tempo de fluoroscopia (rs=0,66). Não foi observada diferença estatisticamente significativa na relação DAP/peso entre procedimentos terapêuticos e diagnósticos. Houve ampla variação da relação DAP/peso entre os procedimentos terapêuticos (p<0.001). Conclusões A proporção DAP/peso é a medida mais simples e aplicável para avaliar a exposição radiológica em uma população pediátrica. Apesar da escassa literatura disponível, as doses obtidas no presente estudo foram semelhantes àquelas encontradas anteriormente. Estudos de validação e comparação são importantes na avaliação do impacto de estratégias para redução da exposição radiológica nessa população. (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)
ABSTRACT
Abstract Background In recent years the increasing number of interventional procedures has resulted in growing concerns regarding radiation exposure for patients and staff. The evaluation of radiation exposure in children is difficult due to the great variability in body weight. Therefore, reference levels of radiation are not well defined for this population. Objectives To study and validate the ratio of dose-area product (DAP) to patient weight as a reference measurement of radiation for hemodynamic congenital heart disease procedures in children. Methods This observational multicenter study uses data obtained from a Brazilian registry of cardiac catheterization for congenital heart disease from March 2013 to June 2014. Inclusion criteria were all patients aged <18 years old undergoing hemodynamic procedures for congenital heart disease, with recorded DAP doses. P-value < 0.05 was considered as statistically significant. Results This study evaluated 429 patients with median age and weight of 50 (10, 103) months and 15 (7, 28) kg, respectively. Median DAP was 742.2 (288.8, 1,791.5) μGy.m2. There was a good correlation between DAP and weight-fluoroscopic time product(rs=0.66). No statistically significant difference was observed in DAP/weight ratio between therapeutic and diagnostic procedures. There was a wide variation in the DAP/weight ratio among the therapeutic procedures (p<0.001). Conclusions The DAP/weight ratio is the simplest and most applicable measurement to evaluate radiation exposure in a pediatric population. Although there is limited literature available, the doses obtained in the present study were similar to those previously found. Ongoing research is important to evaluate the impact of strategies to reduce radiation exposure in this population (Arq Bras Cardiol. 2020; [online].ahead print, PP.0-0)
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Radiation Exposure / Heart Defects, Congenital Type of study: Controlled clinical trial Limits: Adolescent / Aged / Child / Child, preschool / Humans Country/Region as subject: South America / Brazil Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2020 Type: Article Affiliation country: Brazil / United kingdom Institution/Affiliation country: Fundação Universitária de Cardiologia/BR / Hammersmith Hospital/GB / Hospital do Coração/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Radiation Exposure / Heart Defects, Congenital Type of study: Controlled clinical trial Limits: Adolescent / Aged / Child / Child, preschool / Humans Country/Region as subject: South America / Brazil Language: English / Portuguese Journal: Arq. bras. cardiol Journal subject: Cardiology Year: 2020 Type: Article Affiliation country: Brazil / United kingdom Institution/Affiliation country: Fundação Universitária de Cardiologia/BR / Hammersmith Hospital/GB / Hospital do Coração/BR