Your browser doesn't support javascript.
loading
Diseño y optimización de un tubo policromático de citometría de flujo para inmunofenotipo linfocitario periférico / Design and optimization of a polychromatic tube of flow cytometry for peripheral lymphocyte immunophenotype
Zúñiga Rosales, Yaíma; Villegas Valverde, Carlos Agustín; Torres Rives, Bárbara; Hernández Reyes, Evelyn.
  • Zúñiga Rosales, Yaíma; ICBP Victoria de Girón. Centro Nacional de Genética Médica. La Habana. CU
  • Villegas Valverde, Carlos Agustín; Instituto Nacional de Oncología y Radiobiología. La Habana. CU
  • Torres Rives, Bárbara; ICBP Victoria de Girón. Centro Nacional de Genética Médica. La Habana. CU
  • Hernández Reyes, Evelyn; ICBP Victoria de Girón. Centro Nacional de Genética Médica. La Habana. CU
Rev. cuba. hematol. inmunol. hemoter ; 36(3): e1151, jul.-set. 2020. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1156441
RESUMEN

Introducción:

La citometría de flujo permite la cuantificación de las subpoblaciones de linfocitos con una elevada sensibilidad, especificidad y objetividad. Estas ventajas solo se logran con un proceso laborioso de diseño individualizado y controlado para cada experimento.

Objetivo:

Diseñar un protocolo de un solo tubo policromático de citometría flujo para inmunofenotipo linfocitario periférico.

Métodos:

Se realizó un estudio experimental in vitro con muestras de sangre periférica obtenidas de tres voluntarios sanos, en el Centro Nacional de Genética Médica, en marzo de 2019. El tubo se compuso de seis marcadores de linaje para identificar linfocitos B, T, natural killer y natural killer T. Se desarrolló un protocolo de lisis de hematíes sin lavado. Se emplearon anticuerpos monoclonales conjugados con fluorocromos. El punto óptimo de concentración correspondió al mayor índice de tinción y conservación de los porcentajes de positividad de cada población. Se realizó la construcción progresiva del tubo y se propuso una estrategia lógica de secuencia de ventanas para el análisis de datos.

Resultados:

Los marcadores seleccionados permitieron realizar correctamente el inmunofenotipo linfocitario periférico. En los cinco puntos de titulación se observaron buenas discriminaciones entre las señales positivas y negativas, excepto para el anti-CD56 que presentó una tendencia decreciente del índice de tinción. El volumen total de conjugados requeridos para la determinación de los 6 antígenos fue de 3,75 μL por tubo.

Conclusiones:

Se obtuvo un tubo policromático que permite el inmunofenotipo periférico de forma rápida y precisa por seis antígenos linfocitarios simultáneamente, con el empleo de pequeños volúmenes de conjugado y sangre(AU)
ABSTRACT

Introduction:

Flow cytometry allows quantification of lymphocyte subpopulations with high sensitivity, specificity and objectivity. These advantages are only achieved through the hardworking process of individualized and controlled design for each experiment.

Objective:

To design a flow cytometry protocol of a single polychromatic tube for peripheral lymphocyte immunophenotype.

Methods:

An experimental in vitro study was carried out, in March 2019, with peripheral blood samples obtained from three healthy volunteers, at the National Center for Medical Genetics. The tube was made up of six lineage markers for identifying natural B and T lymphocytes, natural killers and natural killer T cells. A protocol was developed for red blood cell lysis without washing. Fluorochrome-conjugated monoclonal antibodies were used. The optimal point of concentration corresponded to the highest staining index and preservation of the positivity percentages of each population. Progressive tube construction was performed and a logical window sequence strategy was proposed for data analysis.

Results:

The chosen markers allowed to carry out correct peripheral lymphocyte immunophenotype. Good discriminations between positive and negative signals were observed at the five titration points, except for anti-CD56, which presented a decreasing trend in the staining index. The total volume of conjugates required for determination of the six antigens was 3.75 μL per tube.

Conclusions:

A polychromatic tube was obtained that allows to carry out peripheral immunophenotype quickly and precisely by six lymphocyte antigens simultaneously, with the use of small volumes of conjugate and blood(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Process Optimization / Flow Cytometry / Genetics, Medical Type of study: Practice guideline Limits: Humans Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2020 Type: Article Affiliation country: Cuba Institution/Affiliation country: ICBP Victoria de Girón/CU / Instituto Nacional de Oncología y Radiobiología/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Process Optimization / Flow Cytometry / Genetics, Medical Type of study: Practice guideline Limits: Humans Language: Spanish Journal: Rev. cuba. hematol. inmunol. hemoter Journal subject: Allergy and Immunology / Hematology Year: 2020 Type: Article Affiliation country: Cuba Institution/Affiliation country: ICBP Victoria de Girón/CU / Instituto Nacional de Oncología y Radiobiología/CU