Your browser doesn't support javascript.
loading
Efectividad del implante de lente fáquica ACR-128 tras un año de seguimiento / Effectiveness of an ACR-128 phakic lens implant after one year's follow-up
Cárdenas Díaz, Taimi; Feng qi, L; Vargas Vergara, Juan P; González Ortega, María F; Guerra Almaguer, Michel.
  • Cárdenas Díaz, Taimi; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Feng qi, L; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Vargas Vergara, Juan P; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • González Ortega, María F; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
  • Guerra Almaguer, Michel; Instituto Cubano de Oftalmología Ramón Pando Ferrer. La Habana. CU
Rev. cuba. invest. bioméd ; 39(4): e754, oct.-dic. 2020. tab
Article in Spanish | LILACS, CUMED | ID: biblio-1156452
RESUMEN

Introducción:

La corrección de ametropías moderadas-severas mediante lentes fáquicas permite conservar la acomodación, además, de obtener una mejor calidad óptica, reversibilidad del procedimiento y la opción de corregir defectos refractivos residuales mediante cirugía corneal mínima invasiva.

Objetivo:

Determinar la efectividad de los lentes fáquicos ACR-128 en la corrección de la alta miopía tras un año de su implante.

Método:

Se realizó un estudio transversal en 67 ojos de 36 pacientes con miopía corregida con lente fáquica ACR-128. Se determinaron las características biométricas y refractivas por ojo, relación entre el componente esférico esperado y el observado, distribución por ojos el componente esférico esperado y el observado, relación entre cilindro queratométrico pre y posoperatorio y relación entre la agudeza visual sin corrección y la agudeza visual mejor corregida en el pre y posoperatorio.

Resultados:

La edad media fue 28,06 ± 6,14(25 mujeres, 11 hombres) el equivalente esférico preoperatorio OD promedio de -10,77 ± 4,23 dioptrías y OI promedio de -10,77 ± 3,72 dioptrías. El componente esférico en dioptrías esperado (-0,56 ± 0,38) y observado (-0,43 ± 0,69) sin diferencias estadísticamente significativas (p = 0,14). El cilindro queratométrico en dioptrías, pre (1,41 ± 0,74) y posoperatorio (1,24 ± 0,88) sin astigmatismo inducido (p = 0,12). El 100 por ciento tenía agudeza visual sin corrección preoperatoria ≤ 0,1 y posoperatoria ≥ 0,5.

Conclusiones:

Un año después del implante de lente fáquica ACR-128 en la corrección de la alta miopía el tratamiento continúa efectivo, pues reduce el componente esférico al deseado y mantenerlo, no inducir astigmatismo y mantener mejor agudeza visual(AU)
ABSTRACT

Introduction:

Correction of moderate-severe ametropia with phakic lenses makes it possible to preserve accommodation and provides better optical quality, reversibility of the procedure and the option of correcting residual refractive defects by minimally invasive corneal surgery.

Objective:

Determine the effectiveness of ACR-128 phakic lenses for high myopia correction one year after implantation.

Method:

A cross-sectional study was conducted of 67 eyes of 36 patients with myopia corrected with ACR-128 phakic lenses. Determination was made of the biometric and refractive characteristics of each eye, the relationship between the expected and the observed spherical component, the distribution of the expected and the observed spherical component per eye, the relationship between the pre- and postoperative keratometric cylinder, and the relationship between pre- and postoperative uncorrected and best corrected visual acuity.

Results:

Mean age was 28.06 ± 6.14 (25 women, 11 men). Average preoperative spherical equivalent was -10.77 ± 4.23 diopters RE and -10.77 ± 3.72 diopters LE. Spherical component in diopters expected (-0.56 ± 0.38) and observed (-0.43 ± 0.69), without statistically significant differences (p= 0.14). Keratometric cylinder in diopters preoperative (1.41 ± 0.74) and postoperative (1.24 ± 0.88), without induced astigmatism (p = 0.12). In 100 percent visual acuity without correction was #8804; 0.1 preoperative and ≥ 0.5 postoperative.

Conclusions:

One year after ACR-128 phakic lens implantation for high myopia correction, the treatment remains effective, reducing the spherical component and maintaining it at the desired level, not inducing astigmatism and preserving best visual acuity(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Cornea / Lens Implantation, Intraocular / Myopia Type of study: Observational study / Prevalence study / Risk factors Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. invest. bioméd Journal subject: Medicine Year: 2020 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Cornea / Lens Implantation, Intraocular / Myopia Type of study: Observational study / Prevalence study / Risk factors Limits: Female / Humans / Male Language: Spanish Journal: Rev. cuba. invest. bioméd Journal subject: Medicine Year: 2020 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU