RESUMEN
Un acceso vascular funcional asegura una calidad de vida para todos aquellos pacientes con IRCT que requieren de una terapia de sustitución renal óptima. Dentro de los problemas más frecuentes en los centros de diálisis respecto al manejo de los accesos vasculares se encuentra el no contar con métodos de monitorización para detectar precozmente la disfuncionalidad de un acceso vascular y así poder preservar el óptimo funcionamiento de éste. PROPÓSITO con el fin de establecer un método de monitorización no invasivo, específico, de bajo costo y reproducible que lograra pesquisar precozmente la disfuncionalidad de un CVCT y fuera utilizado en la práctica clínica por el personal médico y de enfermería.

METODOLOGÍA:

Conscientes de este problema realizamos un estudio observacional analítico prospectivo, con el fin de detectar factores predictores en la disfuncionalidad de un CVCT (catéter venoso central tunelizado) en hemodiálisis. Analizamos 32 pacientes portadores de CVCT del centro de diálisis de la Pontificia Universidad Católica de Chile, durante los meses de noviembre 2016 a septiembre 2017 (130 sesiones de diálisis). Programamos todos los CVCT con un QB efectivo (flujo real registrado en máquina de diálisis) de 300ml/min, monitorizando PA (presión arterial de acceso vascular registrado en máquina de diálisis) no < a -180 mmHg y PV (presión venosa de acceso vascular registrada en máquina de diálisis) no > a 150mmHg, evaluando depuración del paciente mediante la medición de KT on line (depuración del paciente por unidad de tiempo real) en cada sesión de diálisis, toma de Rx tórax post instalación de catéter para evaluar ubicación de éste y test de recirculación.

RESULTADOS:

La disfuncionalidad de un CVCT no estaría relacionada con el tipo de catéter (DP-P) sino con su ubicación. Los parámetros de alerta de disfuncionalidad en un CVCT son disminución de PA < -180mm/Hg y PV > 150mm/Hg al programar un QB efectivo de 300ml/min, acompañado de una deficiente depuración del paciente, medido a través de KT on line (hombres < 50 litros, Mujeres < 45 litros).
ABSTRACT
A functional vascular access ensures a quality of life for all patients with ESRD who require optimal renal replacement therapy. Among the most frequent problems in dialysis centers regarding the management of vascular accesses is the lack of monitoring methods to detect early the dysfunction of a vascular access and thus preserve the optimal functioning of it.

PURPOSE:

in order to establish a non-invasive, specific, low-cost and reproducible method of monitoring that would achieve early detection of the dysfunction of a CVCT and be used in clinical practice by medical and nursing staff.

METHODOLOGY:

Aware of this problem, we performed a prospective analytical observational study in order to detect predictive factors in the dysfunction of a CVCT (tunneled central venous catheter) in hemodialysis. We analyzed 32 patients with CVCT from the dialysis center of the Pontificia Universidad Católica de Chile, during the months of November 2016 to September 2017 (130 sessions of dialysis). We programmed all the CVCT with an effective QB (real flow registered in dialysis machine) of 300ml / min, monitoring PA (blood pressure of vascular access registered in dialysis machine) not pressure) registered in a dialysis machine) no> at 150mmHg, evaluating the patient's depuration by measuring KT on line (depuration of the patient per unit of real time) in each dialysis session, taking a chest x-ray post catheter installation to evaluate the location of This and recirculation test.

RESULTS:

The dysfunction of a CVCT would not be related to the type of catheter (DP-P) but to its location. The parameters of dysfunctional alert in a CVCT are decrease in BP <-180mm / Hg and PV> 150mm / Hg when programming an effective QB of 300ml / min, accompanied by a deficient depuration of the patient, measured through KT on line ( men <50 liters, Women <45 liters).
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Patients / Renal Dialysis / Central Venous Catheters Type of study: Observational study / Prognostic study / Risk factors / Screening study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Horiz. enferm Journal subject: Nursing Year: 2019 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Patients / Renal Dialysis / Central Venous Catheters Type of study: Observational study / Prognostic study / Risk factors / Screening study Limits: Adult / Aged / Aged80 / Female / Humans / Male Language: Spanish Journal: Horiz. enferm Journal subject: Nursing Year: 2019 Type: Article Affiliation country: Chile Institution/Affiliation country: Pontificia Universidad Católica de Chile/CL