Your browser doesn't support javascript.
loading
Sensibilidad y especificidad de la presión de pulso ampliada como prueba diagnóstica de IRC estadio K/DOQI III-b / Sensitivity and specificity of increased pulse pressure as a diagnostic test for K/DOQI III-b
Pérez-Castañeda, Ana I; Vázquez-de Anda, Gilberto F; Cerecero-Aguirre, Patricia; Rivas-Ruiz, Rodolfo; Delaye-Aguilar, María G; Talavera, Juan O.
  • Pérez-Castañeda, Ana I; Universidad Autónoma del Estado de México. Clínica Multidisciplinaria de Salud. MX
  • Vázquez-de Anda, Gilberto F; Universidad Autónoma del Estado de México. Clínica Multidisciplinaria de Salud. MX
  • Cerecero-Aguirre, Patricia; Universidad Autónoma del Estado de México. Clínica Multidisciplinaria de Salud. MX
  • Rivas-Ruiz, Rodolfo; Instituto Mexicano del Seguro Social. Centro Médico Nacional Siglo XXI. Centro de Adiestramiento en Investigación Clínica. Ciudad de México. MX
  • Delaye-Aguilar, María G; Universidad Autónoma del Estado de México. Clínica Multidisciplinaria de Salud. MX
  • Talavera, Juan O; Centro Médico ABC. Dirección de Enseñanza e Investigación. Ciudad de México. MX
Gac. méd. Méx ; 156(5): 432-437, sep.-oct. 2020. tab, graf
Article in Spanish | LILACS | ID: biblio-1249942
RESUMEN
Resumen

Introducción:

La presión de pulso ampliada (PPA) se asocia a un filtrado glomerular calculado ≤ 60/mL/minuto/1.73 m2, por lo que puede ser útil como prueba diagnóstica para identificar a personas con insuficiencia renal crónica (IRC) estadio K/DOQI III-b.

Objetivo:

Determinar la utilidad de la PPA como prueba diagnóstica de IRC estadio K/DOQI III-b.

Método:

Estudio de prueba diagnóstica que incluyó a pacientes adultos sin comorbilidades, registrados en la Cohorte de Trabajadores de la Salud. Se utilizó la fórmula CKD-EPI para calcular la filtración glomerular. Se determinó la presión de pulso restando la presión arterial diastólica a la presión arterial sistólica. Se calculó sensibilidad, especificidad, valor predictivo positivo, valor predictivo negativo y prevalencia. Se elaboró una curva ROC para determinar el área bajo la curva.

Resultados:

Se incluyeron 6215 pacientes. Se observó que una PPA ≥ 50 mm Hg tuvo sensibilidad de 74 %, especificidad de 70 %, valor predictivo positivo de 1 %, valor predictivo negativo de 100 % y prevalencia de 1 %. El punto de inflexión en la curva ROC para identificar IRC K/DOQI III-b fue de 0.71.

Conclusión:

La PPA ≥ 50 mm Hg es útil como prueba diagnóstica para identificar a personas con IRC estadio K/DOQI III-b.
ABSTRACT
Abstract

Introduction:

Increased pulse pressure (IPP) is associated an estimated glomerular filtration ≤ 60/mL/min/1.73 m2; thus, it can be useful as a diagnostic test to identify people with K/DOQI stage III-b chronic kidney disease (CKD).

Objective:

To determine the usefulness of IPP as a diagnostic test for K/DOQI stage III-b CKD.

Method:

Diagnostic test study that included adult patients without comorbidities, registered in the Health Workers Cohort. The CKD-EPI formula was used to calculate glomerular filtration. Pulse pressure was determined by subtracting diastolic from systolic blood pressure. Sensitivity, specificity, positive predictive value, negative predictive value and prevalence were calculated using standard formulas. A ROC curve was generated to determine the area under the curve.

Results:

A total of 6,215 patients were included. An IPP ≥ 50 mmHg was observed to have a sensitivity of 74 %, specificity of 70 %, positive predictive value of 1 %, negative predictive value of 100 % and a prevalence of 1 %. The inflection point in the ROC curve to identify K/DOQI III-b CKD was 0.71.

Conclusion:

An IPP ≥ 50 mmHg is useful as a diagnostic test to identify people with K/DOQI stage III-b CKD.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Blood Pressure / Renal Insufficiency, Chronic Type of study: Diagnostic study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Spanish Journal: Gac. méd. Méx Journal subject: Medicine Year: 2020 Type: Article Affiliation country: Mexico Institution/Affiliation country: Centro Médico ABC/MX / Instituto Mexicano del Seguro Social/MX / Universidad Autónoma del Estado de México/MX

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Blood Pressure / Renal Insufficiency, Chronic Type of study: Diagnostic study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Male Language: Spanish Journal: Gac. méd. Méx Journal subject: Medicine Year: 2020 Type: Article Affiliation country: Mexico Institution/Affiliation country: Centro Médico ABC/MX / Instituto Mexicano del Seguro Social/MX / Universidad Autónoma del Estado de México/MX