Autologous whole Blood Patch in Repair of Leaking Filtering Bleds : Case Report on Initial Experience
Pedro-Egbe, C. N; Waziri-Erameh, J. M.
  • Pedro-Egbe, C. N; s.af
  • Waziri-Erameh, J. M; s.af
port harcourt med. J ; 2(1): 78-80, 2007.
Article in English | AIM | ID: biblio-1274035
ABSTRACT

Aim:

To show the value of autologous whole blood patch in the management of leaking filtering blebs in Nigerian eyes.

Methods:

Two male patients who had trabeculectomy and adjunctive application of mitomycin C subsequently developed leaking blebs at the University of Benin Teaching Hospital; Benin City; Nigeria. A 27-gauge needle was used to inject 0.75- 1.0ml of whole blood under the conjunctival buttonhole.

Result:

The procedure succeeded in arresting the bleb leak but the trabeculectomy failed after 7 and 10 months respectively. Repeat trabeculectomy using another site remained successful after 2 years and 18 months respectively.

Conclusion:

Autologous whole blood patch is successful in sealing leaking blebs complications following trabeculectomy
Subject(s)
Full text: Available Index: AIM (Africa) Main subject: Whole Blood Coagulation Time / Blood Transfusion / Trabeculectomy / Blister / Filtering Surgery Language: English Journal: Port harcourt med. J Year: 2007 Type: Article