Your browser doesn't support javascript.
loading
Estimación del riesgo en cirugía cardíaca en el "mundo real": ArgenSCORE ajustado al centro / Cardiovascular Surgery Risk Assessment in the "Real World": ArgenSCORE Adjusted by Center
CAROSELLA, VICTORIO C.; GRANCELLI, HUGO; STUTZBACH, PABLO; SIGAL, ALAN R.; LERECH, EZEQUIEL; MORCOS, LUDMILA; VILLALBA, CÉSAR; LOWENSTEIN HABER, DIEGO; HITA, ALEJANDRO; NOJEK, CARLOS.
  • CAROSELLA, VICTORIO C.; Sanatorio Las Lomas. Instituto Cardiovascular San Isidro. Servicio de Cardiología. AR
  • GRANCELLI, HUGO; Sanatorio de la Trinidad. Servicio de Cardiología. AR
  • STUTZBACH, PABLO; Sanatorio Las Lomas. Instituto Cardiovascular San Isidro. Servicio de Cardiología. AR
  • SIGAL, ALAN R.; Consejo Argentino de Residentes de Cardiología. AR
  • LERECH, EZEQUIEL; Consejo Argentino de Residentes de Cardiología. AR
  • MORCOS, LUDMILA; Consejo Argentino de Residentes de Cardiología. AR
  • VILLALBA, CÉSAR; Consejo Argentino de Residentes de Cardiología. AR
  • LOWENSTEIN HABER, DIEGO; Consejo Argentino de Residentes de Cardiología. AR
  • HITA, ALEJANDRO; Hospital Universitario Austral. Servicio de Cardiología. AR
  • NOJEK, CARLOS; Sanatorio Finochietto. Servicio de Cirugía Cardiovascular. AR
Rev. argent. cardiol ; 89(1): 3-12, mar. 2021. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1279713
RESUMEN
RESUMEN

Introducción:

El ArgenSCORE tiene una versión original (I) desarrollada en 1999 sobre una población con mortalidad del 8% y una versión II (recalibración del modelo en 2007) sobre una población con una mortalidad del 4%. Evaluamos en el registro CONAREC XVI la hipótesis de que el ArgenSCORE II podría estimar mejor el riesgo de mortalidad intrahospitalaria en los centros con baja mortalidad; en cambio, el ArgenSCORE I estimaría mejor la mortalidad en los centros con alta mortalidad. Material y

métodos:

Se analizaron 2548 pacientes de 44 centros del registro prospectivo y multicéntrico en cirugía cardíaca, CONAREC XVI. En cada centro se evaluó la mortalidad media observada (MO) y se calculó la mortalidad estimada media (ME) aplicando ambas versiones del ArgenSCORE. Se calculó la relación MO/ME de cada centro para los dos modelos y se evaluó si había diferencias significativas mediante el test Z.

Resultados:

La mortalidad intrahospitalaria del registro fue del 7,69%. El 75% de los centros (33/44) presentaban una mortalidad mayor del 6%. En centros con mortalidad menor del 6%, al aplicar el ArgenSCORE II, la relación MO/ME mostró valores cercanos a 1 y sin diferencias significativas. En centros con mortalidad mayor del 6%, el ArgenSCORE II subestima significativamente el riesgo. En cambio, cuando se aplica en estos centros el ArgenSCORE I, la relación MO/ME es cercana a 1 (sin diferencias significativas).

Conclusiones:

En centros con mortalidad menor del 6%, es recomendable utilizar el ArgenSCORE II-recalibrado; en centros con mortalidad mayor del 6%, tiene mejor desempeño el ArgenSCORE I-original.
ABSTRACT
ABSTRACT

Background:

The ArgenSCORE I was developed in 1999 on a population with 8% mortality. The ArgenSCORE II emerged after recalibrating the original model in 2007 on a validation population with 4% mortality. Using the CONAREC XVI registry, we evaluated the hypothesis that the ArgenSCORE II could better predict the risk of in-hospital mortality in centers with low mortality, whereas the ArgenSCORE I could better predict mortality in centers with high mortality.

Methods:

A total of 2548 patients from 44 centers of the prospective and multicenter cardiac surgery CONAREC XVI registry, were analyzed. Mean observed mortality (OM) and mean expected mortality (EM) were estimated applying both versions of the ArgenSCORE. The OM/EM ratio was calculated in each center for both models and the Z test was used to evaluate significant differences.

Results:

In-hospital mortality was 7.69% for the entire registry. In 75% of the centers (33/44) mortality was >6%. In centers with mortality <6%, the OM/EM ratio was close to 1 after applying the ArgenSCORE II, without significant differences. In centers with mortality >6%, the ArgenSCORE II significantly underestimated the risk. On the contrary, when the ArgenSCORE I was applied in these centers, the OM/EM ratio was close to 1, without significant differences.

Conclusions:

The recalibrated ArgenSCORE II is recommended in centers with mortality <6%, while in those with mortality >6% the original ArgenSCORE I has better performance.


Full text: Available Index: LILACS (Americas) Type of study: Etiology study / Prognostic study / Risk factors Language: Spanish Journal: Rev. argent. cardiol Journal subject: Cardiology / Doen‡as Cardiovasculares Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Consejo Argentino de Residentes de Cardiología/AR / Hospital Universitario Austral/AR / Sanatorio Finochietto/AR / Sanatorio Las Lomas/AR / Sanatorio de la Trinidad/AR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Type of study: Etiology study / Prognostic study / Risk factors Language: Spanish Journal: Rev. argent. cardiol Journal subject: Cardiology / Doen‡as Cardiovasculares Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Consejo Argentino de Residentes de Cardiología/AR / Hospital Universitario Austral/AR / Sanatorio Finochietto/AR / Sanatorio Las Lomas/AR / Sanatorio de la Trinidad/AR