Reprodutibilidade, objetividade e validade do instrumento de avaliação do nível de atividade física de idosos ­ Curitibativa (INAFI) / Reproducibility, objectivity and validity of the instrument measuring the level of physical activity in the elderly - Curitibativa (INAFI)
Rauchbach, Rosemary; Wendling, Neila Maria de Souza; Scorsato, Anderson Paulo; Reis, José Carlos Ferreira; Dantas, Estélio Henrique Martin.
  • Rauchbach, Rosemary; Universidad del Pacífico Privada. Assunção. PY
  • Scorsato, Anderson Paulo; Universidade Federal do Paraná (UFPR). Curitiba/PR. BR
  • Reis, José Carlos Ferreira; Centro Universitário Santo Agostinho (UNIFSA). Universidade Federal do Estado do Rio de Janeiro (UNIRIO). Rio de Janeiro. BR
  • Dantas, Estélio Henrique Martin; Universidade Federal do Estado do Rio de Janeiro (UNIRIO). Rio de Janeiro. BR
Fisioter. Bras ; 20(3): 317-328, Junho 11, 2019.
Article in Portuguese | LILACS | ID: biblio-1281235
RESUMO
O estudo propôs verificar a autenticidade científica do Instrumento de Avaliação do Nível de Atividade Física de Idosos (INAFI). Participaram 64 idosos, com 69,37 ± 6,70 anos (mulheres) e 70,5 ± 3,54 anos (homens). O instrumento adotado foi o acelerômetro GT3X, Actigraph (USA). Na análise geral do instrumento, comparação entre os grupos A e B (reprodutibilidade, mesmo entrevistador), o INAFI apresentou bom desempenho, p = 0,6956, grupos B e C (objetividade, entrevistadores diferentes), o instrumento foi razoável, p = 0,5047. No diagrama de dispersão observou-se que o viés A e B (= 0,5), B e C (= 6,61), é muito próximo de Zero, demonstrando que há concordância na maneira de aplicar as entrevistas. Na comparação, INAFI X acelerômetro foi necessário homogeneizar a diferença no tamanho das escalas, dividindo as variáveis pelas suas respectivas médias. Os resultados das análises total/INAFI (MET/min/sem) X counts/min eixo1; total/INAFI (MET/min/sem) X counts/min vetor magnitude; total/atividade leve/INAFI, (< 3 METs) X total/light e lifestyle/acelerômetro (1,5-2,9 METs); total/atividade moderada/INAFI (> 3 METs) X total/atividade moderada/acelerômetro (3-5,9 METs) obteve-se um viés (= zero), portanto existe uma forte concordância entre as medidas dos dois instrumentos. Podemos afirmar que o INAFI se mostrou eficiente ao propósito para qual foi construído, portanto possui autenticidade científica. (AU)
ABSTRACT
The study proposed to verify the scientific authenticity of the Instrument Measuring the Level of Physical Activity in the Elderly (INAFI). Sixty-four elderly individuals participated, with 69.37 ± 6.70 years (women) and 70.5 ± 3.54 years (men). The instrument adopted was the GT3X accelerometer, Actigraph (USA). In the general analysis of the instrument, comparison between groups A and B (reproducibility, same interviewer), INAFI presented good performance, p = 0.6956, groups B and C (objectivity, different interviewers), the instrument was reasonable, p = 0.5047. In the dispersion diagram it was observed that the bias A and B (= 0.5), B and C (= 6.61), is very close to Zero, demonstrating that there is agreement in the way of applying the interviews. In the comparison, INAFI X accelerometer was necessary to homogenize the difference in the size of the scales, dividing the variables by their respective means. The results of the analyzes total / INAFI (MET / min / without) X counts / min axis1; total / INAFI (MET / min / without) X counts / min vector magnitude; total / light activity / INAFI, (<3 METs) X total / light and lifestyle / accelerometer (1.5-2.9 METs); total / moderate activity / INAFI (> 3 METs) total X / moderate activity / accelerometer (3-5.9 METs) was obtained a bias (= zero), therefore there is a strong agreement between the measurements of the two instruments. We can say that INAFI was efficient for the purpose for which it was built, so it has scientific authenticity. (AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Aged / Exercise / Reproducibility of Results / Motor Activity Limits: Aged / Aged80 / Female / Humans / Male Language: Portuguese Journal: Fisioter. Bras Journal subject: MEDICINA FISICA E REABILITACAO Year: 2019 Type: Article Affiliation country: Brazil / Paraguay Institution/Affiliation country: Centro Universitário Santo Agostinho (UNIFSA)/BR / Universidad del Pacífico Privada/PY / Universidade Federal do Estado do Rio de Janeiro (UNIRIO)/BR / Universidade Federal do Paraná (UFPR)/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Aged / Exercise / Reproducibility of Results / Motor Activity Limits: Aged / Aged80 / Female / Humans / Male Language: Portuguese Journal: Fisioter. Bras Journal subject: MEDICINA FISICA E REABILITACAO Year: 2019 Type: Article Affiliation country: Brazil / Paraguay Institution/Affiliation country: Centro Universitário Santo Agostinho (UNIFSA)/BR / Universidad del Pacífico Privada/PY / Universidade Federal do Estado do Rio de Janeiro (UNIRIO)/BR / Universidade Federal do Paraná (UFPR)/BR