Your browser doesn't support javascript.
loading
Validación de un simulador para el entrenamiento de la capsulotomía posterior láser en oftalmología / Validation of a simulator for teaching posterior capsulotomy with laser in ophthalmology
Hernández López, Iván; Ruiz Carreño, Ricardo; Cárdenas Chacón, Daylin.
  • Hernández López, Iván; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Ruiz Carreño, Ricardo; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
  • Cárdenas Chacón, Daylin; Instituto Cubano de Oftalmología Ramón Pando Ferrer. CU
Educ. med. super ; 35(2): e2205, 2021. tab, graf
Article in Spanish | LILACS, CUMED | ID: biblio-1286229
RESUMEN

Introducción:

La capsulotomía láser representa el único tratamiento efectivo para tratar la opacidad de cápsula posterior -causa más común de disminución de la visión después de una cirugía de catarata-. Este proceder es sencillo, pero no exento de complicaciones. Hasta ahora su aprendizaje se realiza directamente en los pacientes. El uso de simuladores permite el aprendizaje de la técnica sin dañar al paciente y sin la obligada presencia del profesor.

Objetivo:

Validar la confección de un modelo de ojo artificial como simulador para el entrenamiento de residentes de oftalmología en capsulotomía posterior con láser.

Métodos:

Estudio observacional, descriptivo y prospectivo en el Instituto Cubano de Oftalmología "Ramón Pando Ferrer", realizado desde febrero hasta marzo de 2019. Se confeccionó un modelo que simula el ojo pseudofáquico con opacidad de cápsula posterior. Se eligieron ocho residentes de oftalmología de primer año que nunca habían realizado una capsulotomía láser. Todos observaron la ejecución de la capsulotomía en pacientes reales y en el modelo docente, mientras recibían la explicación de la técnica. Posteriormente, cada estudiante efectuó el proceder sobre el simulador en tres ocasiones, y se evaluó en cuanto al completamiento de la capsulotomía y los impactos al lente.

Resultados:

Se obtuvo un modelo de simulación para el entrenamiento de la capsulotomía posterior láser con el uso de materiales reusables. El promedio de disparos para completar el proceder fue superior al necesario en pacientes reales. No obstante, el número de disparos e impactos de láser en el lente intraocular se redujo con las sucesivas sesiones de entrenamiento.

Conclusiones:

El simulador confeccionado es económico y de fácil factura. Su uso resulta funcional para el entrenamiento sistemático de la capsulotomía posterior con Nd. YAG láser, sin riesgo de daño para el paciente. Contribuye a perfeccionar el enfoque y a minimizar los impactos en la lente intraocular, por lo que se muestra como un medio didáctico útil para la formación y evaluación de habilidades de los residentes de oftalmología(AU)
ABSTRACT

Introduction:

Laser capsulotomy is the only effective treatment for posterior capsule opacity, the commonest cause of decreased vision after cataract surgery. This procedure is simple, but not without complications. Until now, learning such procedure has been carried out directly on patients. Using simulators allows learning the technique without harming patients and without the professor's obligatory presence.

Objective:

To validate the creation of an artificial eye model to be used as a simulator for the training of Ophthalmology residents in posterior capsulotomy with laser.

Methods:

Observational, descriptive and prospective study carried out, from February to March 2019, at Ramón Pando Ferrer Cuban Institute of Ophthalmology. A model was made that simulates the pseudophakic eye with posterior capsule opacity. Eight first-year Ophthalmology residents who had never performed a laser capsulotomy were selected. All the participants observed the performance of capsulotomy in real patients, as well as in the teaching model, while receiving the explanation regarding the technique. Subsequently, each student performed the procedure with the simulator on three occasions, and received an evaluation based on the completion of the capsulotomy and the impacts to the lens.

Results:

A simulation model was obtained for training posterior laser capsulotomy with the use of reusable materials. The average number of shots to complete the procedure was higher than necessary in real patients. However, the number of shots and laser impacts on the intraocular lens decreased with successive training sessions.

Conclusions:

The simulator created is cheap and easy to make. Its use is functional for the systematic training of posterior capsulotomy with neodymium. Yttrium aluminium garnet (YAG) laser did not have any risks to the patient. It contributes to perfecting the focus and minimizing the impacts on the intraocular lens; therefore, it is shown as a useful didactic means for the training and evaluation of skills of Ophthalmology residents(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Laser Therapy / Posterior Capsulotomy / Simulation Training / Lenses, Intraocular Type of study: Observational study / Risk factors Limits: Humans Language: Spanish Journal: Educ. med. super Journal subject: Education Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Laser Therapy / Posterior Capsulotomy / Simulation Training / Lenses, Intraocular Type of study: Observational study / Risk factors Limits: Humans Language: Spanish Journal: Educ. med. super Journal subject: Education Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Cubano de Oftalmología Ramón Pando Ferrer/CU