Your browser doesn't support javascript.
loading
Disfunción diastólica y relación con arritmias: un vínculo más allá de la fibrilación auricular / Diastolic dysfunction and its relationship with arrhythmias: more than just linked to atrial fibrillation
López-Patiño, Helber G; Niño-Pulido, César D; Vásquez-Trespalacios, Elsa M; Aristizábal-Aristizábal, Julián M; Duque-Ramírez, Mauricio.
  • López-Patiño, Helber G; Universidad CES. Medellín. CO
  • Niño-Pulido, César D; Universidad CES. CES Cardiología. Medellín. CO
  • Vásquez-Trespalacios, Elsa M; Universidad CES. Grupo de Investigación en Epidemiologia y Bioestadística. Medellín. CO
  • Aristizábal-Aristizábal, Julián M; Universidad CES. CES Cardiología. Medellín. CO
  • Duque-Ramírez, Mauricio; Universidad CES. CES Cardiología. Medellín. CO
Rev. colomb. cardiol ; 27(5): 362-367, sep.-oct. 2020. tab
Article in Spanish | LILACS, COLNAL | ID: biblio-1289243
RESUMEN
Resumen

Introducción:

La falla cardíaca es un problema de salud pública, cuya prevalencia aumenta con la edad. Hasta el 50% de los casos tiene fracción de eyección preservada. Pocos estudios evalúan arritmias en este tipo de población. Se conoce una asociación con fibrilación auricular, pero se ignora qué otro tipo de arritmias pueden estar presentes.

Objetivo:

Describir arritmias por medio de monitorización Holter de 24 horas en pacientes con disfunción diastólica. Materiales y

métodos:

Se realizó un estudio observacional, descriptivo y retrospectivo, en el que se evaluaron y compararon los parámetros de la monitorización Holter de 24 horas en pacientes con disfunción diastólica, provenientes de un solo centro y residentes en Medellín, durante el año 2017.

Resultados:

67 pacientes tenían disfunción diastólica; la mayoría correspondió a mujeres (65.7%). El promedio de edad fue 71 años, el índice de masa corporal fue de 26,8 y las comorbilidades más frecuentes fueron hipertensión arterial (68,7%), fibrilación auricular (19,4%) y enfermedad coronaria (19,4%). El promedio de fracción de eyección fue de 58%; el 67,2% tenía disfunción diastólica tipo I y el promedio del volumen de la aurícula izquierda fue de 33 ml/m2. Las arritmias más frecuentes fueron taquicardia atrial no sostenida (40,3%), fibrilación auricular (10,4%), taquicardia ventricular monomórfica (7,5%) y taquicardia por reentrada intranodal (1.5%). Se presentó bloqueo AV de primer grado (22,4%) y bloqueo sinoatrial (1,5%). El promedio de variabilidad de la frecuencia cardíaca fue 126.23.

Conclusiones:

En pacientes con disfunción diastólica tipo I y II se documentaron varios tipos de arritmias más allá de la fibrilación auricular. No hubo alteraciones en la variabilidad de la frecuencia cardíaca y tampoco en el tiempo de QTc. Dada la existencia de trasfondo fisiopatológico común, se debe evaluar en estudios futuros la relación entre arritmias y disfunción diastólica, además de su potencial tratamiento y modificación de su curso clínico.
ABSTRACT
Abstract

Introduction:

Heart failure is a public health problem, with a prevalence that increases with age. Up to 50% of cases have a preserve ejection fraction. Few studies have evaluated arrhythmias in this population type. It is known that there is an association with atrial fibrillation, but other types of arrhythmias that could be present are ignored.

Objective:

To describe arrhythmias using 24 hour Holter monitoring in patients with diastolic dysfunction. Materials and

methods:

An observational, descriptive, and retrospective study was performed in which the parameters from 24 hour Holter monitoring were evaluated and compared in patients with diastolic dysfunction from a single centre and resident in Medellin, during the year 2017.

Results:

A total of 67 patients had diastolic dysfunction, in which the majority (65.7%) were women. The mean age was 71 years, with a mean body mass index of 26.8. The most frequent comorbidities were arterial hypertension (68.7%), atrial fibrillation (19.4%), and coronary disease (19.4%). The mean ejection fraction was 58%; 67.2% had a type I diastolic dysfunction, and the mean atrial volume was 33 ml/m2. The most common arrhythmias were discontinuous atrial flutter (40.3%), atrial fibrillation (10.4%), monomorphic ventricular tachycardia (7.5%) and nodal re-entrant tachycardia (1.5%). First degree AV block (22.4%) and sinoatrial block (1.5%) were observed. The mean heart rate variability was 126.23.

Conclusions:

Several types of arrhythmias other than atrial fibrillation were documented in patients with type I and type II diastolic dysfunction. There were no changes in the heart rate variability or in the QTc time. Given the existence of a common pathophysiological background, further studies are needed in order to evaluate the relationship between arrhythmias and diastolic dysfunction, as well as any potential treatment and modification of its clinical course.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Arrhythmias, Cardiac / Heart Failure, Diastolic Type of study: Observational study / Risk factors Limits: Aged Language: Spanish Journal: Rev. colomb. cardiol Journal subject: Cardiology Year: 2020 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad CES/CO

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Arrhythmias, Cardiac / Heart Failure, Diastolic Type of study: Observational study / Risk factors Limits: Aged Language: Spanish Journal: Rev. colomb. cardiol Journal subject: Cardiology Year: 2020 Type: Article Affiliation country: Colombia Institution/Affiliation country: Universidad CES/CO