RESUMEN

INTRODUCCIÓN:

Una de las complicaciones de la osteosíntesis retrógrada del escafoides es la protrusión del tornillo en la articulación radiocarpiana, dada la limitada visualización intraoperatoria del polo proximal del escafoides con las proyecciones tradicionales.

OBJETIVO:

Evaluar la capacidad de una nueva proyección radiológica, la proyección "tangencial del escafoides dorsal", o TED, para identificar tornillos prominentes radiocarpianos durante la osteosíntesis retrógrada del escafoides con tornillos canulados. MATERIALES Y

MÉTODOS:

Estudio cadavérico en muñecas frescas congeladas. Se introdujo en el escafoides un tornillo canulado con técnica retrógrada estándar. La proyección TED fue evaluada en 5 muñecas, con angulaciones del antebrazo de 15°, 30° y 45° para definir la mejor visualización del polo proximal del escafoides y del tornillo. Se comparó la capacidad para identificar la prominencia del tornillo en el polo proximal de la proyección TED de 30° con 5 proyecciones tradicionales de escafoides en 9 muñecas. El tornillo se posicionó a nivel de la superficie del escafoides, y luego se avanzó a intervalos de 0,5 mm bajo visualización directa por artrotomía dorsal. Tras cada intervalo, se repitieron todas las proyecciones para determinar su capacidad de detectar tornillos prominentes en el escafoides.

RESULTADOS:

La mejor visualización del polo proximal del escafoides se logró con la proyección TED de 30°. Al comparar la proyección TED de 30° y las tradicionales, con la TED se logró identificar tornillos prominentes a 0,8 mm promedio, seguida por la proyección posteroanterior con cubitalización y extensión a 1.3 mm (p » 0.014), con una alta precisión y correlación interobservador de estas proyecciones.

CONCLUSIÓN:

La proyección TED demostró ser la más sensible para detectar tornillos prominentes en la articulación radiocarpiana. Su uso rutinario podría evitar complicaciones durante la osteosíntesis.
ABSTRACT

INTRODUCTION:

One of the complications of the retrograde percutaneous scaphoid fixation is the protrusion of the screw in the radiocarpal joint due to the limited intraoperative visualization of the proximal pole of the scaphoid with the traditional radiographic views. OBJETIVE To evaluate the sensitivity of a novel radiographic view (the skyline scaphoid view, SSV) to detect screws protruding in the radiocarpal joint during the retrograde fixation of the scaphoid. MATERIALS AND

METHODS:

We studied nine cadaverous fresh frozen wrists. A retrograde cannulated screw was inserted in the scaphoid. To validate the SSV, 5 wrists were studied, comparing 3 forearm angulations (15°, 30° and 45°) to get the best visualization of the proximal pole and screw. We compared the ability to identify the protrusion of the screw in the proximal pole of the 30° SSV with that of 5 standard scaphoid radiographic views in 9 wrists. The screw was positioned at the level of the surface of the scaphoid, and was sequentially protruded in 0.5 mm increments, with direct visualization of its tip through a dorsal capsulotomy. After each increment, all views were repeated to determine if they were able to detect screws projecting from the scaphoid.

RESULTS:

The best visualization of the proximal pole of the scaphoid was found with the 30° SSV. In the comparison of the 30° SSV and the standard views, with the SSV we were able to identify the protrusion of the screws at an average of 0.8 mm, followed by the posterior-anterior view with ulnar deviation and extension at 1.3 mm (p » 0.014), with high precision and interobserver agreement regarding these views.

CONCLUSION:

The SSV was the most sensitive view to detect protruding screws in the proximal pole of the scaphoid. Its routine use could avoid complications during osteosynthesis.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Wrist Joint / Bone Screws / Scaphoid Bone / Fracture Fixation, Internal Type of study: Diagnostic study Limits: Humans Language: Spanish Journal: Rev. chil. ortop. traumatol Journal subject: Orthopedics / Traumatology Year: 2021 Type: Article Affiliation country: Chile Institution/Affiliation country: Hospital Puerto Montt Dr. Eduardo Schütz Schroeder/CL / Hospital del Trabajador/CL

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Wrist Joint / Bone Screws / Scaphoid Bone / Fracture Fixation, Internal Type of study: Diagnostic study Limits: Humans Language: Spanish Journal: Rev. chil. ortop. traumatol Journal subject: Orthopedics / Traumatology Year: 2021 Type: Article Affiliation country: Chile Institution/Affiliation country: Hospital Puerto Montt Dr. Eduardo Schütz Schroeder/CL / Hospital del Trabajador/CL