Your browser doesn't support javascript.
loading
Instrumento de auditoría de cumplimiento del protocolo de prevención de neumonía asociada a la ventilación mecánica / Audit instrument for compliance with the protocol for the prevention of pneumonia associated with mechanical ventilation
Pastrana-Domínguez, Cindy; Zárate-Grajales, Rosa Amarilis; Velázquez-Moreno, Eduardo.
  • Pastrana-Domínguez, Cindy; Calidad e Investigación de Enfermería. Hospital Regional "Lic. Adolfo López Mateos". Instituto de Seguridad y Servicios Sociales de los Trabajadores del Estado. Ciudad de México. MX
  • Zárate-Grajales, Rosa Amarilis; Dirección de la Escuela Nacional de Enfermería y Obstetricia. Escuela Nacional de Enfermería y Obstetricia. Universidad Nacional Autónoma de México. Ciudad de México. MX
  • Velázquez-Moreno, Eduardo; Programa de Maestría en Enfermería. Facultad de Estudios Superiores Zaragoza. Universidad Nacional Autónoma de México. Ciudad de México. MX
Rev. enferm. Inst. Mex. Seguro Soc ; 28(4): 319-333, Oct-dic 2020. tab
Article in Spanish | LILACS, BDENF | ID: biblio-1344065
RESUMEN

Introducción:

la neumonía asociada a la ventilación mecánica (NAVM) es una de las infecciones vinculadas con la atención sanitaria más común en las unidades de cuidados intensivos (UCI). Las investigaciones recientes han centrado su atención en el cumplimiento de la atención de enfermería concebida como un proceso y han dejado de lado elementos relacionados con la estructura de las unidades y el resultado de la atención.

Objetivo:

diseñar y validar el instrumento de auditoría de cumplimiento del protocolo de prevención de NAVM en una UCI.

Metodología:

es un estudio observacional y analítico con dos mediciones realizado en una UCI de un hospital regional al sur de la Ciudad de México con 360 observaciones sobre las medidas de prevención no farmacológicas en la UCI para prevenir la NAVM. Para la elaboración del instrumento se seleccionaron fuentes documentales, con extracción de recomendaciones por grado de evidencia y el proceso de validación mediante panel de expertos.

Resultados:

se obtuvieron recomendaciones con grados de evidencia altos y se realizaron ajustes al instrumento durante su creación posterior. El tiempo de aplicación del instrumento fue de 25 a 30 minutos. Se aplicó la prueba de Kuder-Richardson 20 como índice de consistencia interna con un valor de 0.878 en la prueba preliminar y de 0.853 en la aplicación final; se identificaron relaciones entre las dimensiones del instrumento y las respuestas similares intraobservador estadísticamente significativas. No se obtuvieron dimensiones subyacentes del análisis factorial exploratorio.

Conclusiones:

el instrumento mostró características psicométricas deseables que respaldan la confiabilidad de su medición; previa adaptación cultural, se considera viable su aplicación en procesos de auditoría y proyectos de mejora en unidades de cuidados intensivos por su fácil aplicación, su exhaustividad y aproximación al modelo de evaluación de la calidad de la asistencia sanitaria.
ABSTRACT

Introduction:

Pneumonia associated with mechanical ventilation (PAMV) is one of the most common healthcare-associated infections in intensive care units (ICU). Recent re- search has focused on the fulfillment of nursing care as a process, leaving aside elements related to the structure of the units, or the result of care.

Objective:

Design and validate the instrument for auditing compliance with the PAMV prevention protocol in an ICU.

Methods:

Observational, analytical study, with two measurements, carried out in an ICU of a Regional Hospital in south of Mexico City, with 360 observations on non-pharmacological prevention measures in the ICU to prevent PAMV. In the elaboration of the instrument, documentary sources were selected, of recommendations by level of evidence were extracted, and process of the validation was carried out by a panel of experts.

Results:

Recommendations were obtained with high levels of evidence, adjustments were made to the instrument during its subsequent creation. The application time of the instrument ranges from 25 to 30 minutes. The Kuder Richardson 20 test was applied as an internal consistency index with a value of 0.878 in a pilot test and in a final application of 0.853, associations were found between the dimensions of the instrument and similar statistically significant intra-observer responses. No underlying dimensions were obtained from the exploratory factor analysis.

Conclusions:

The instrument presented desirable psycho- metric characteristics that support the reliability of its measurement; after cultural adjustment, its application in audit processes and improvement projects in intensive care units is considered viable, due to its easy application, exhaustive- ness and closeness to observe the evaluation model of quality of health care.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Pneumonia, Ventilator-Associated / Intensive Care Units / Nursing Care Type of study: Practice guideline / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. enferm. Inst. Mex. Seguro Soc Journal subject: Nursing Year: 2020 Type: Article Affiliation country: Mexico Institution/Affiliation country: Calidad e Investigación de Enfermería/MX / Dirección de la Escuela Nacional de Enfermería y Obstetricia/MX / Programa de Maestría en Enfermería/MX

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Pneumonia, Ventilator-Associated / Intensive Care Units / Nursing Care Type of study: Practice guideline / Observational study / Prognostic study / Risk factors Limits: Humans Language: Spanish Journal: Rev. enferm. Inst. Mex. Seguro Soc Journal subject: Nursing Year: 2020 Type: Article Affiliation country: Mexico Institution/Affiliation country: Calidad e Investigación de Enfermería/MX / Dirección de la Escuela Nacional de Enfermería y Obstetricia/MX / Programa de Maestría en Enfermería/MX