Your browser doesn't support javascript.
loading
O balanço hídrico pós-extubação se associa com falha da extubação: um estudo de coorte / Postextubation fluid balance is associated with extubation failure: a cohort study
Santos, Priscila Albrecht dos; Ribas, Alexandre; Quadros, Thiele Cabral Coelho; Blattner, Clarissa Netto; Boniatti, Márcio Manozzo.
  • Santos, Priscila Albrecht dos; Pontifícia Universidade Católica do Rio Grande do Sul. Hospital São Lucas. Departamento de Terapia Intensiva. Porto Alegre. BR
  • Ribas, Alexandre; Pontifícia Universidade Católica do Rio Grande do Sul. Hospital São Lucas. Departamento de Terapia Intensiva. Porto Alegre. BR
  • Quadros, Thiele Cabral Coelho; Pontifícia Universidade Católica do Rio Grande do Sul. Hospital São Lucas. Departamento de Terapia Intensiva. Porto Alegre. BR
  • Blattner, Clarissa Netto; Pontifícia Universidade Católica do Rio Grande do Sul. Hospital São Lucas. Departamento de Terapia Intensiva. Porto Alegre. BR
  • Boniatti, Márcio Manozzo; Universidade Federal do Rio Grande do Sul. Hospital de Clínicas de Poto Alegre. Departamento de Terapia Intensiva. Porto Alegre. BR
Rev. bras. ter. intensiva ; 33(3): 422-427, jul.-set. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1347300
RESUMO
RESUMO

Objetivo:

Avaliar se há associação entre o balanço hídrico nas 48 horas após a extubação e a falha da extubação.

Métodos:

Este é um estudo de coorte prospectiva que incluiu os pacientes admitidos à unidade de terapia intensiva de um hospital terciário no sul do Brasil entre março e dezembro de 2019. Incluíram-se os pacientes que necessitaram de ventilação mecânica por pelo menos 24 horas e foram extubados durante o período do estudo. O desfecho primário foi falha da extubação, considerada como necessidade de reintubar dentro das primeiras 72 horas após a extubação. O desfecho secundário foi um desfecho combinado de falha da extubação ou necessidade de ventilação não invasiva terapêutica.

Resultados:

Foram incluídos 101 pacientes. Observou-se falha da extubação em 29 (28,7%) deles. Na análise univariada, pacientes com balanço hídrico negativo acima de 1L no período de 48 horas após a extubação tiveram menor taxa de falha da extubação (12,0%), em comparação a pacientes com balanço hídrico negativo nas 48 horas após a extubação menor que 1L (34,2%; p = 0,033). A duração da ventilação mecânica e o balanço hídrico negativo nas 48 horas após a extubação inferior a 1L se associaram com falha da extubação na análise multivariada quando corrigido pelo Simplified Acute Physiology Score 3. Quando avaliou-se o desfecho combinado, apenas o balanço hídrico nas 48 horas pós-extubação inferior a 1L manteve associação, quando corrigido pelo Simplified Acute Physiology Score 3 e duração da ventilação mecânica.

Conclusão:

O balanço hídrico nas 48 horas após a extubação se associa com falha da extubação. São necessários mais estudos para avaliar se evitar um balanço hídrico positivo nesse período poderia melhorar os desfechos do desmame.
ABSTRACT
ABSTRACT

Objective:

To assess whether there is an association between 48-hour postextubation fluid balance and extubation failure.

Methods:

This was a prospective cohort study that included patients admitted to the intensive care unit of a tertiary hospital in southern Brazil from March 2019 to December 2019. Patients who required mechanical ventilation for at least 24 hours and who were extubated during the study period were included. The primary outcome was extubation failure, considered as the need for reintubation in the first 72 hours after extubation. The secondary outcome was a combined outcome with extubation failure or the need for therapeutic noninvasive ventilation.

Results:

A total of 101 patients were included. Extubation failure was observed in 29 (28.7%) patients. In univariate analysis, patients with a negative 48-hour postextubation fluid balance higher than one liter had a lower rate of extubation failure (12.0%) than patients with a negative 48-hour postextubation fluid balance lower than 1L (34.2%; p = 0.033). Mechanical ventilation duration and negative 48-hour postextubation fluid balance lower than one liter were associated with extubation failure when corrected for Simplified Acute Physiology Score 3 in multivariate analysis. When we evaluated the combined outcome, only negative 48-hour postextubation lower than 1L maintained an association when corrected for for Simplified Acute Physiology Score 3 and mechanical ventilation duration.

Conclusion:

The 48-hour postextubation fluid balance is associated with extubation failure. Further studies are necessary to assess whether avoiding positive fluid balance in this period might improve weaning outcomes.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Airway Extubation Type of study: Etiology study / Incidence study / Observational study / Risk factors Limits: Humans Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontifícia Universidade Católica do Rio Grande do Sul/BR / Universidade Federal do Rio Grande do Sul/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Airway Extubation Type of study: Etiology study / Incidence study / Observational study / Risk factors Limits: Humans Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Pontifícia Universidade Católica do Rio Grande do Sul/BR / Universidade Federal do Rio Grande do Sul/BR