Lesão pulmonar autoinflingida: é possível identificar o risco? Relato de caso / Self-inflicted lung injury: is it possible to identify the risk? A case report
Pérez, Joaquín; Dorado, Javier Hernán; Navarro, Emiliano; Accoce, Matías.
  • Pérez, Joaquín; Sanatorio Anchorena de San Martín. Buenos Aires. AR
  • Dorado, Javier Hernán; Sanatorio Anchorena de San Martín. Buenos Aires. AR
  • Navarro, Emiliano; Hospital General de Agudos Carlos G. Durand. Buenos Aires. AR
  • Accoce, Matías; Sanatorio Anchorena de San Martín. Buenos Aires. AR
Rev. bras. ter. intensiva ; 33(3): 461-468, jul.-set. 2021. tab, graf
Article in English, Portuguese | LILACS | ID: biblio-1347304
RESUMO
RESUMO A respiração espontânea pode ser prejudicial para pacientes com pulmões previamente lesados, especialmente na vigência de síndrome do desconforto respiratório agudo. Mais ainda, a incapacidade de assumir a respiração totalmente espontânea durante a ventilação mecânica e a necessidade de voltar à ventilação mecânica controlada se associam com mortalidade mais alta. Existe uma lacuna no conhecimento em relação aos parâmetros que poderiam ser úteis para predizer o risco de lesão pulmonar autoinflingida pelo paciente e detecção da incapacidade de assumir a respiração espontânea. Relata-se o caso de um paciente com lesão pulmonar autoinflingida e as correspondentes variáveis, básicas e avançadas, de monitoramento da mecânica do sistema respiratório, além dos resultados fisiológicos e clínicos relacionados à respiração espontânea durante ventilação mecânica. O paciente era um homem caucasiano com 33 anos de idade e história clínica de AIDS, que apresentou síndrome do desconforto respiratório agudo e necessitou ser submetido à ventilação mecânica invasiva após falha do suporte ventilatório não invasivo. Durante os períodos de ventilação controlada, adotou-se estratégia de ventilação protetora, e o paciente mostrou evidente melhora, tanto do ponto de vista clínico quanto radiográfico. Contudo, durante cada período de respiração espontânea sob ventilação com pressão de suporte, apesar dos parâmetros iniciais adequados, das regulagens rigorosamente estabelecidas e do estrito monitoramento, o paciente desenvolveu hipoxemia progressiva e piora da mecânica do sistema respiratório, com deterioração radiográfica claramente correlacionada (lesão pulmonar autoinflingida pelo paciente). Após falha de três tentativas de respiração espontânea, o paciente faleceu por hipoxemia refratária no 29° dia. Neste caso, as variáveis básicas e avançadas convencionais não foram suficientes para identificar a aptidão para respirar espontaneamente ou predizer o risco de desenvolver lesão pulmonar autoinflingida pelo paciente durante a ventilação de suporte parcial.
ABSTRACT
ABSTRACT Spontaneous breathing can be deleterious in patients with previously injured lungs, especially in acute respiratory distress syndrome. Moreover, the failure to assume spontaneous breathing during mechanical ventilation and the need to switch back to controlled mechanical ventilation are associated with higher mortality. There is a gap of knowledge regarding which parameters might be useful to predict the risk of patient self-inflicted lung injury and to detect the inability to assume spontaneous breathing. We report a case of patient self-inflicted lung injury, the corresponding basic and advanced monitoring of the respiratory system mechanics and physiological and clinical results related to spontaneous breathing. The patient was a 33-year-old Caucasian man with a medical history of AIDS who developed acute respiratory distress syndrome and needed invasive mechanical ventilation after noninvasive ventilatory support failure. During the controlled ventilation periods, a protective ventilation strategy was adopted, and the patient showed clear clinical and radiographic improvement. However, during each spontaneous breathing period under pressure support ventilation, despite adequate initial parameters and a strictly adjusted ventilatory setting and monitoring, the patient developed progressive hypoxemia and worsening of respiratory system mechanics with a clearly correlated radiographic deterioration (patient self-inflicted lung injury). After failing three spontaneous breathing assumption trials, he died on day 29 due to refractory hypoxemia. Conventional basic and advanced monitoring variables in this case were not sufficient to identify the aptitude to breathe spontaneously or to predict the risk and development of patient self-inflicted lung injury during partial support ventilation.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Respiratory Distress Syndrome, Newborn / Lung Injury Type of study: Diagnostic study / Etiology study / Prognostic study / Risk factors Limits: Adult / Humans / Male Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital General de Agudos Carlos G. Durand/AR / Sanatorio Anchorena de San Martín/AR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiratory Distress Syndrome, Newborn / Lung Injury Type of study: Diagnostic study / Etiology study / Prognostic study / Risk factors Limits: Adult / Humans / Male Language: English / Portuguese Journal: Rev. bras. ter. intensiva Journal subject: Critical Care Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Hospital General de Agudos Carlos G. Durand/AR / Sanatorio Anchorena de San Martín/AR