Your browser doesn't support javascript.
loading
Desarrollo tecnológico e introducción del inyectable succinilcolina 50 mg/mL en el cuadro básico de medicamentos nacional de Cuba / Technological development and introduction of the injectable succinylcholine 50 mg/mL in the basic table of national medicines of Cuba / Desenvolvimento tecnológico e introdução da succinilcolina injetável 50 mg/mL na mesa da medicina básica de Cuba
Burguet-Lago, Nancy; Troche-Concepción, Yenilen; Baró-Rodríguez, Leisy; Martínez-Betancourt, María Victoria; Toledo-Carrabeo, Griset.
  • Burguet-Lago, Nancy; Empresa Laboratorios Aica. Departamento de I+D. La Habana. CU
  • Troche-Concepción, Yenilen; Empresa Laboratorios Aica. Departamento de I+D. La Habana. CU
  • Baró-Rodríguez, Leisy; Empresa Laboratorios Aica. Departamento de I+D. La Habana. CU
  • Martínez-Betancourt, María Victoria; Empresa Laboratorios Aica. Departamento de Aseguramiento y Control de la Calidad. La Habana.
  • Toledo-Carrabeo, Griset; Empresa Laboratorios Aica. Departamento de I+D. La Habana. CU
Rev. colomb. ciencias quim. farm ; 50(2): 339-351, mayo-ago. 2021. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1347328
RESUMEN
RESUMEN

Introducción:

El inyectable succinilcolina 50 mg/mL se utiliza para intubaciones traqueales rápidas.

Objetivo:

Desarrollar e introducir el inyectable succinilcolina 50 mg/mL en el cuadro básico de medicamentos. Tres variantes de formulación fueron diseñadas dos con preservantes antimicrobianos y presentación (bulbos 6R y 10R) y una sin preservantes (bulbos 6R).

Metodología:

Se validaron los métodos empleados para el control de calidad y estabilidad. A los lotes elaborados a escala de laboratorio, piloto e industrial con la fórmula seleccionada se les realizó estudio de estabilidad acelerada y vida útil. Las variantes diseñadas evidenciaron adecuada calidad, la no preservada fue seleccionada para realizar lotes a diferentes escalas. Las técnicas cromatográficas empleadas para la cuantificación de la succinilcolina cumplieron con los criterios de validación establecidos.

Resultados:

Se demostró el desempeño de las pruebas de esterilidad y ensayo de endotoxinas bacterianas. El producto en estudio de estabilidad indicó un adecuado comportamiento físico, químico y micro-biológico durante el período evaluado. Se comprobó la factibilidad del desarrollo tecnológico, con la fórmula seleccionada para el inyectable succinilcolina 50 mg/mL. Se introdujo el inyectable en el cuadro básico de medicamentos nacional.
ABSTRACT
SUMMARY

Introduction:

The injectable succinylcholine 50 mg/mL is used for rapid tracheal intubations.

Aim:

To develop and introduce the injectable succinylcholine 50 mg/mL into the basic drug table. Three formulation variants were designed two with antimicrobial and presentation preservatives (6R and 10R bulbs) and one unpreserved (6R bulbs).

Methodology:

The methods used for quality control and stability were validated. Laboratory, pilot and industrial-scale batches with the selected formula were studied for accelerated stability and service life. The designed variants showed adequate quality, selecting the non-preserved, to make batches at different scales. Chromatographic techniques used for the quantification of succinylcholine met established validation criteria.

Results:

The performance of sterility tests and bacterial endotoxin testing was demonstrated. The product under stability study indicated adequate physical and chemical behavior during the period evaluated. The feasibility of technological development was verified, with the formula selected for the injectable succinylcholine 50 mg/mL. Injectable was introduced in the national medicines basic table.
RESUMO
RESUMO

Introdução:

A succinilcolina injetável 50 mg/mL é utilizada para intubações traqueais rápidas.

Objetivo:

Desenvolver e introduzir a succinilcolina injetável 50 mg/mL na tabela básica de medicamentos. Três variantes de formulação foram projetadas duas com conservantes antimicrobianos e apresentação (lâmpadas 6R e 10R) e uma sem conservantes (lâmpadas 6R).

Metodologia:

Foram validados os métodos utilizados para o controle de qualidade e estabilidade. Estudos acelerados de estabilidade e vida de prateleira foram realizados nos lotes produzidos em escala laboratorial, piloto e industrial com a fórmula selecionada. As variantes projetadas apresentaram qualidade adequada, a não preservada foi selecionada para a realização de lotes em diferentes escalas. As técnicas cromatográficas utilizadas para a quantificação da succinilcolina atenderam aos critérios de validação estabelecidos.

Resultados:

Foi demonstrado o desempenho dos testes de esterilidade e do ensaio de endotoxinas bacterianas. O produto em estudo de estabilidade indicou comportamento físico, químico e microbiológico adequado durante o período avaliado. Foi verificada a viabilidade do desenvolvimento tecnológico, com a fórmula selecionada para a succinilcolina injetável 50 mg/mL. O injetável foi introduzido na tabela nacional de medicamentos básicos.


Full text: Available Index: LILACS (Americas) Country/Region as subject: Cuba Language: Spanish Journal: Rev. colomb. ciencias quim. farm Journal subject: Pharmacy / Chemistry Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Empresa Laboratorios Aica/CU

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Country/Region as subject: Cuba Language: Spanish Journal: Rev. colomb. ciencias quim. farm Journal subject: Pharmacy / Chemistry Year: 2021 Type: Article Affiliation country: Cuba Institution/Affiliation country: Empresa Laboratorios Aica/CU