Diseño de un dispositivo de asistencia ventilatoria temporal de lazo cerrado basado en bolsa válvula-mascarilla / Design of a closed-loop temporary ventilation assistance device based on bag valve mask
Balsells, Jorge A; García, Luis G; Morales, Iván; López, Víctor; Carranza, Víctor; López, Saúl; Villatoro, Astrid C; García, Luis A; Castillo, Juan C; Nájera, Hasel; Cabrera, Hector.
  • Balsells, Jorge A; Universidad de San Carlos de Guatemala. Laboratorio de Innovación FabLab-DIGI. Guatemala. GT
  • García, Luis G; International Centre for Theoretical Physics. Italia. IT
  • Morales, Iván; Universidad de San Carlos de Guatemala. Escuela de Ciencias Físicas y Matemáticas. Guatemala. GT
  • López, Víctor; Instituto Nacional de Electrificación. Guatemala. GT
  • Carranza, Víctor; Universidad de San Carlos de Guatemala. Facultad de Ingeniería. Escuela de Ingeniería Mecánica Eléctrica. Guatemala. GT
  • López, Saúl; Universidad de San Carlos de Guatemala. Facultad de Ingeniería. Escuela de Ingeniería Mecánica Eléctrica. Guatemala. GT
  • Villatoro, Astrid C; Universidad de San Carlos de Guatemala. Facultad de Arquitectura. Guatemala. GT
  • García, Luis A; Universidad de San Carlos de Guatemala. Facultad de Ciencias Médicas. Guatemala. GT
  • Castillo, Juan C; Universidad de San Carlos de Guatemala. Facultad de Ciencias Médicas. Guatemala. GT
  • Nájera, Hasel; Universidad de San Carlos de Guatemala. Facultad de Ciencias Médicas. Guatemala. GT
  • Cabrera, Hector; Hospital General San Juan de Dios. Guatemala. GT
Cienc. tecnol. salud ; 7(3)26 de noviembre 2020. il 27 c
Article in Spanish | LILACS, DIGIUSAC, LIGCSA | ID: biblio-1348107
RESUMEN
Desde inicios del 2020, el mundo se ha visto afectado por la COVID-19 causada por el SARS-CoV-2, que en agosto lo padecen más de 31 millones de pacientes, algunos de los cuales presentan el síndrome de distrés respiratorio, que requiere de ventilación mecánica. Por el alto número de contagios, la disponibilidad de ventiladores para el tratamiento es escasa. Se presenta la descripción de un prototipo de un dispositivo de asistencia ventilatoria temporal de lazo cerrado de bajo costo; el AR_CODEX, basado en una bolsa válvula-mascarilla (BVM), que contribuye al mantenimiento ventilatorio mínimo del paciente durante un tiempo corto en casos donde no hay disponibilidad de ventiladores mecánicos. Para esto, se diseñó y construyó un sistema mecánico ajustable que compresiona la bolsa de ventilación, el cual cuenta con sensores de flujo y presión. Además, se elaboró una interfaz gráfica para un adecuado monitoreo del paciente y un sistema de control para variables como volumen, presión máxima, frecuencia respiratoria y relación inspiración espiración. Por otro lado, existe un problema de sensibilidad en el sensor de flujo debido a varios factores, como la variación del voltaje en los motores. Adicionalmente, la implementación de un lazo cerrado es importante para compensar variaciones aleatorias en el funcionamiento del dispositivo. Es necesario realizar pruebas en animales para evaluar el correcto funcionamiento de AR_CODEX en seres vivos.
ABSTRACT
In early 2020, the world has been affected from Covid-19 caused by SARS-CoV-2. By August there were more than 31 million patients, some of them suffering from respiratory distress that requires mechanical ventilation. Due to the rise of infection rates there is no ventilator availability for the treatment. In this work we describe a reduced cost closed loop temporal assisted ventilation device prototype, AR_CODEX. It is based on mask valve bag (BVM from its Spanish initials), contributing to the minimum ventilation maintenance for the patient du-ring a short period of time when there is no mechanical ventilation availability. For this purpose an adjustable mechanical system was designed and built to pressurize the ventilation bag that is equipped with flux and pres-sure sensors. Additionally a graphical interface was developed to include adequate monitoring and controlling system for volume, maximum pressure, respiratory frequency and inhalation/exhalation rate. In addition there is a sensibility issue on the flux sensor due to engine voltage variation. A closed loop implementation is important to overcome aleatory variations during the device operation. It is needed to run AR_CODEX device performance test on animals to evaluate prior to use it directly on human patients.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Ventilators, Mechanical / Respiratory Rate / Masks Type of study: Controlled clinical trial / Prognostic study Limits: Humans Language: Spanish Journal: Cienc. tecnol. salud Journal subject: Alimenta‡Æo / GestÆo de Ciˆncia, Tecnologia e Inova‡Æo em Sa£de / Medicina / Medicina Veterin ria / TECNOLOGIA, INDéSTRIA, AGRICULTURA Year: 2020 Type: Article Affiliation country: Guatemala / Italy Institution/Affiliation country: Hospital General San Juan de Dios/GT / Instituto Nacional de Electrificación/GT / International Centre for Theoretical Physics/IT / Universidad de San Carlos de Guatemala/GT / Universidad de San Carlos de Guatemala/GT

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Respiration, Artificial / Ventilators, Mechanical / Respiratory Rate / Masks Type of study: Controlled clinical trial / Prognostic study Limits: Humans Language: Spanish Journal: Cienc. tecnol. salud Journal subject: Alimenta‡Æo / GestÆo de Ciˆncia, Tecnologia e Inova‡Æo em Sa£de / Medicina / Medicina Veterin ria / TECNOLOGIA, INDéSTRIA, AGRICULTURA Year: 2020 Type: Article Affiliation country: Guatemala / Italy Institution/Affiliation country: Hospital General San Juan de Dios/GT / Instituto Nacional de Electrificación/GT / International Centre for Theoretical Physics/IT / Universidad de San Carlos de Guatemala/GT / Universidad de San Carlos de Guatemala/GT