Avaliação de ultrafiltração como alternativa à flotação por ar dissolvido no pós-tratamento do efluente de lodos ativados — estudo em escala piloto na estação de tratamento de esgoto Brasília norte / Evaluation of ultrafiltration as an alternative to dissolved air flotation for the post-treatment of activated sludge effluent — pilot study in the Brasília norte wastewater treatment plant
Bertolossi, Vinicius Mendes; Neder, Tatiana Finageiv; Brandão, Cristina Celia Silveira.
  • Bertolossi, Vinicius Mendes; Universidade de Brasília. Brasília. BR
  • Neder, Tatiana Finageiv; Universidade de Brasília. Brasília. BR
  • Brandão, Cristina Celia Silveira; Universidade de Brasília. Brasília. BR
Eng. sanit. ambient ; 26(6): 1003-1014, nov.-dez. 2021. tab, graf
Article in Portuguese | LILACS-Express | LILACS | ID: biblio-1350723
RESUMO
RESUMO A melhoria da qualidade dos efluentes das estações de tratamento de esgotos Brasília Norte e Sul tornou-se premente após o corpo receptor dos seus efluentes, o lago Paranoá, passar a ser utilizado como manancial de abastecimento. Este trabalho apresenta estudo comparativo entre o tratamento terciário por ultrafiltração precedido por coagulação em escala piloto e a flotação por ar dissolvido existente na estação de tratamento de esgotos Brasília Norte. A instalação piloto de ultrafiltração e a flotação por ar dissolvido foram alimentadas pela mesma matriz, o efluente da etapa de lodos ativados das estações de tratamento de esgotos Brasília Norte, após coagulação. Foram avaliadas sete condições operacionais da instalação piloto de ultrafiltração variando-se a vazão, o tempo de operação entre limpezas e a duração da limpeza física. O comportamento operacional e a qualidade do efluente produzido foram monitorados. O aumento do fluxo do permeado (de 40,2 para 50,6 e 61,0 L.m−2.h−1) e do tempo de operação entre as limpezas (de 25 para 38 e 50 min), bem como a redução da duração da retrolavagem (de 80 para 60 e 30 s) resultaram em evolução mais intensa da pressão transmembrana. A ultrafiltração foi mais eficiente do que a flotação por ar dissolvido na remoção de turbidez, sólidos suspensos totais, demanda química de oxigênio e fósforo total, com ganho médio de remoção de 9,4, 13,0, 8,5 e 12,8%, respectivamente. Destaca-se a remoção de coliformes na ultrafiltração, 3,4 log superior à da flotação por ar dissolvido. A utilização da ultrafiltração como alternativa à flotação por ar dissolvido apresenta a vantagem de produzir efluente de melhor qualidade, particularmente no aspecto microbiológico, com menor flutuação da qualidade, porém o tratamento e a destinação do lodo produzido pela ultrafiltração devem ser equacionados.
ABSTRACT
ABSTRACT Improvement in the effluent quality of the Brasília Norte and Brasília Sul wastewater treatment plants became necessary after their effluent receiving body, Paranoá Lake, started being used as source of drinking water for the population of Brasília (Federal District, Brazil). This is a comparative study between the tertiary treatment with ultrafiltration membrane (pilot scale) and the existing dissolved air flotation of Brasília Norte wastewater treatment plant. Both ultrafiltration pilot plant and dissolved air flotation were fed with the same matrix, the effluent of the activated sludge stage of Brasília Norte wastewater treatment plants, after coagulation. Seven operational conditions were evaluated at ultrafiltration pilot plant, with variations in flow rate, time of operation between cleaning processes, and the duration of backwashing. The operational behavior and the quality of the produced effluent were monitored. The increase in permeate flux (from 40.2 to 50.6 and 61.0 L.m−2.h−1) and in the time of operation between cleaning processes (from 25 to 38 and 50 min), as well as the reduction of backwashing duration (from 80 to 60 and 30s), resulted in a more intense evolution of transmembrane pressure. Ultrafiltration was more efficient than dissolved air flotation in the removal of turbidity, total suspended solids, chemical oxygen demand, and total phosphorous, with average gain in removal of 9.4, 13.0, 8.5, and 12.8%, respectively. It is worth mentioning the removal of coliforms by ultrafiltration, which was, on average, 3.4 log higher than that by dissolved air flotation. The use of ultrafiltration as an alternative to dissolved air flotation has the advantage of producing better quality effluent, particularly regarding microbiological aspects, providing lower quality fluctuation; however, treatment and destination of the ultrafiltration waste must be considered.


Full text: Available Index: LILACS (Americas) Country/Region as subject: South America / Brazil Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de Brasília/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Country/Region as subject: South America / Brazil Language: Portuguese Journal: Eng. sanit. ambient Journal subject: Environmental Health / Public Health Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade de Brasília/BR