Your browser doesn't support javascript.
loading
Determinación de anticuerpos anti-dsDNA: evaluación del desempeño de un inmunoensayo quimioluminiscente y correlación con el método de inmunofluorescencia indirecta / Detection of anti-dsDNA antibodies: evaluation of performance of a chemiluminescent immunoassay and correlation to the indirect immunofluorescence assay / Determinação de anticorpos anti-dsDNA: avaliação do desempenho de um imunoensaio quimioluminiscente e correlação com o método de imunoflourescência indireta
Martínez Methol, María Soledad; Ventimiglia, Fernando Daniel; Aristimuño, Ana María; de la Colina, Amelia Noemí; DAgostino, Liliana Elena.
  • Martínez Methol, María Soledad; Facultad de Ciencias Exactas, Universidad Nacional de La Plata. AR
  • Ventimiglia, Fernando Daniel; Laboratorio DAgostino-Bruno. La Plata - Cátedra de Hematología, Facultad de Ciencias Exactas, Universidad Nacional de La Plata - Cátedra de Hematología, Instituto de Ciencias de la Salud, Universidad Nacional Florencio Varela.. AR
  • Aristimuño, Ana María; Laboratorio DAgostino-Bruno. AR
  • de la Colina, Amelia Noemí; Laboratorio DAgostino-Bruno. AR
  • DAgostino, Liliana Elena; Laboratorio DAgostino-Bruno. AR
Acta bioquím. clín. latinoam ; 55(1): 21-29, ene. 2021. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1355545
RESUMEN
Resumen La determinación de anticuerpos anti-dsDNA es de utilidad para el diagnóstico y seguimiento clínico de pacientes con lupus eritematoso sistémico (LES) y es uno de los criterios de clasificación del SLICC-2012. El objetivo del estudio fue verificar el desempeño del inmunoensayo quimioluminiscente (CLIA) QUANTA Flash dsDNA y compararlo con el método en uso de inmunofluorescencia indirecta en Crithidia luciliae (CLIFT). Se analizaron con ambos métodos 195 pacientes con diagnóstico de enfermedades del tejido conectivo y solicitud de anticuerpos anti-dsDNA. Se obtuvieron 38 sueros positivos, 133 negativos y 24 (12,3%) discordantes. Entre estos resultados discordantes, hubo 17 que correspondieron a pacientes con LES y se agruparon en 16 CLIA+/CLIFT- y 1 CLIA-/CLIFT+. Se verificó el desempeño para precisión siguiendo el protocolo EP15-A2 y la linealidad. Se estudió la concordancia mediante el coeficiente Kappa y la correlación con el coeficiente Rho de Spearman. Se observó mayor sensibilidad diagnóstica para CLIA. El grado de acuerdo fue moderado y se obtuvo buena correlación entre los valores cuantitativos de CLIA y los títulos de CLIFT. De acuerdo al buen desempeño encontrado y a los resultados discordantes analizados, la mejor estrategia para la implementación de CLIA sería utilizarla en combinación con CLIFT, lo que aumentaría la sensibilidad diagnóstica sin perder especificidad.
ABSTRACT
Abstract The detection of anti-dsDNA antibodies is useful for diagnosis and clinical monitoring of patients with systemic lupus erythematosus (SLE) and it is part of the classification criteria according to SLICC 2012. The purpose of this study was to verify the performance of the chemiluminescent immunoassay (CLIA) QUANTA Flash dsDNA and to compare it with the method currently in use, i.e the indirect immunofluorescence in Crithidia luciliae (CLIFT). One hundred and ninety five patients, who presented connective tissue diseases and required the study of anti-dsDNA antibodies, were analyzed. Thirty eight positive serum samples were obtained, 133 were negative and 24 (12.3%) in disagreement. Within the discordant results, there were 17 that corresponded to patients with SLE and they were grouped in 16 CLIA+/CLIFT- and 1 CLIA-/CLIFT+. The accuracy performance was assessed according to the EP15-A2 protocol and linearity. Concordance and correlation were calculated with the Kappa and Spearman's Rho coefficient, respectively. Based on the good performance observed and the discordant results analyzed, the best strategy for CLIA implementation would be to combine it with CLIFT, which would increase the diagnostic sensitivity without losing specificity.
RESUMO
Resumo A determinação dos anticorpos anti-dsDNA é de utilidade para o diagnóstico e seguimento clinico de pacientes com lúpus eritematoso sistêmico (LES) e é um dos critérios de classificação do SLICC 2012. O objetivo do estudo foi verificar o desempenho do imunoensaio quimioluminescente (CLIA) QUANTA Flash dsDNA e compará-lo com o método em uso imunofluorescência indireta em Crithidia luciliae (CLIFT). Foram analisados com os dois métodos, 195 pacientes com diagnóstico de doenças do tecido conjuntivo e solicitude de anticorpos anti-dsDNA. Os resultados foram agrupados em 38 soros positivos, 133 negativos e 24 (12,3%) discordantes. Entre esses resultados discordantes, 17 corresponderam a pacientes com LES e se agruparam em 16 CLIA+/CLIFT- e 1 CLIA-/CLIFT+. Foi verificado o desempenho para precisão seguindo o protocolo EP15-A2 e a linearidade. Foi estudada a concordância mediante o coeficiente Kappa e correlação com o coeficiente Rho de Spearman. Observou-se maior sensibilidade diagnóstica para CLIA. O grau de acordo foi moderado e boa correlação foi observada entre os valores quantitativos de CLIA e os títulos de CLIFT. Com base no bom desempenho encontrado e nos resultados discordantes analisados, a melhor estratégia para implementar o CLIA seria utilizá-lo em combinação com o CLIFT, o que aumentaria a sensibilidade do diagnóstico sem perder a especificidade.

Full text: Available Index: LILACS (Americas) Type of study: Diagnostic study / Practice guideline Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Facultad de Ciencias Exactas, Universidad Nacional de La Plata/AR / Laboratorio DAgostino-Bruno/AR / Laboratorio DAgostino-Bruno. La Plata - Cátedra de Hematología, Facultad de Ciencias Exactas, Universidad Nacional de La Plata - Cátedra de Hematología, Instituto de Ciencias de la Salud, Universidad Nacional Florencio Varela./AR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Type of study: Diagnostic study / Practice guideline Language: Spanish Journal: Acta bioquím. clín. latinoam Journal subject: Bioqu¡mica / Qu¡mica Cl¡nica Year: 2021 Type: Article Affiliation country: Argentina Institution/Affiliation country: Facultad de Ciencias Exactas, Universidad Nacional de La Plata/AR / Laboratorio DAgostino-Bruno/AR / Laboratorio DAgostino-Bruno. La Plata - Cátedra de Hematología, Facultad de Ciencias Exactas, Universidad Nacional de La Plata - Cátedra de Hematología, Instituto de Ciencias de la Salud, Universidad Nacional Florencio Varela./AR