RESUMO
RESUMO

Introdução:

A produção de bolsas de sangue total com volume inferior ao esperado é prevista na Portaria de Consolidação no 05/2017, porém, a sua dispensação hoje leva em consideração apenas o teor de hemoglobinas e hematócrito da bolsa.

Objetivo:

Determinar, a partir dos parâmetros técnicos brasileiros existentes, os critérios para o melhor aproveitamento para bolsas de concentrados de hemácias de baixo volume (CHBV) produzidas na Fundação HEMOPA. Material e

métodos:

Foram analisados volume, teor de hemoglobina e hematócrito de 525 bolsas de CHBV provenientes de bolsas duplas sem adição de conservante; triplas convencional com adição de SAG-M (soro fisiológico, adenina, glicose e manitol); triplas top and bottom (TAB) com adição de SAG-M; e quádruplas TAB com filtro "in line" e adição de SAG-M.

Resultados:

Foi observado que 71,43% (375/525) das bolsas de CHBV, independente do tipo da bolsa, apresentavam-se em conformidade para hematócrito e teor de hemoglobina em relação à legislação. As bolsas duplas e triplas convencionais apresentaram os maiores valores de teor de hemoglobina. Observou-se ainda que as bolsas de sangue total coletadas com volumes entre 350 e 404 ml geraram bolsas de CHBV com os menores índices de descarte. O maior descarte das bolsas de CHBV ocorreu quando o volume final ≤250 mL e hemoglobina ≤ 16 g/dL.

Conclusão:

Observou-se que o melhor aproveitamento das bolsas de CHBV ocorreu quando as bolsas de sangue total se encontravam com volumes entre 350 e 404 mL e as bolsas de CHBV apresentavam volume final ≥ 250 mL e hemoglobina ≥ 16g/dL.(AU)
ABSTRACT
ABSTRACT

Introduction:

The production of whole blood bags with a lower volume than expected is approved in the Consolidation Ordinance number 05/2017; however, its dispensation today takes into account only the hemoglobin and hematocrit content of the bag.

Objective:

From the existing Brazilian technical parameters, determine the criteria for the best clinical use for low-volume red cell concentrate (LVRCC) bags produced at the HEMOPA Foundation. Material and

methods:

We analyzed volume, hemoglobin content, and hematocrit of 525 LVRCC bags from double bags without addition of preservative; conventional triple bags with the addition of SAG-M (saline, adenine, glucose, and mannitol); triples bags top and bottom (TAB) with the addition of SAG-M, and quadruple bags TAB with "in line" filter and the addition of SAG-M.

Results:

It was observed that 71.43% (375/525) of bags of LVRCC, regardless of bag type, were in conformance with hematocrit and hemoglobin content concerning Brazilian legislation. With the double and conventional triple bags, they had the highest values of hemoglobin content. It was also observed that the bags of whole blood collected with volumes between 350 and 404 mL generated LVRCC bags with the lowest rate of discard. The greatest discard of LVRCC bags occurred when the final volume ≤ 250 mL and hemoglobin ≤ 16 g/dL.

Conclusion:

It was observed that the best use of LVRCC bags occurred when the whole blood bags were between 350 and 404 mL and the LVRCC bags had a final volume ≥ 250 mL and hemoglobin ≥ 16 g/dL. (AU)
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Blood Transfusion / Platelet-Rich Plasma / Blood Safety / Patient Safety / Hematocrit Language: Portuguese Journal: Medicina (Ribeirao Preto, Online) Journal subject: Medicina Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Pará/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Blood Transfusion / Platelet-Rich Plasma / Blood Safety / Patient Safety / Hematocrit Language: Portuguese Journal: Medicina (Ribeirao Preto, Online) Journal subject: Medicina Year: 2021 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Pará/BR