Your browser doesn't support javascript.
loading
Índice de consistencia cervical o longitud cervical en la predicción de parto pretérmino inminente en pacientes sintomáticas / Cervical consistency index or cervical length in predicting imminent preterm delivery in symptomatic patients
Reyna-Villasmil, Eduardo; Mejía-Montilla, Jorly; Reyna-Villasmil, Nadia; Torres-Cepeda, Duly; Rondón-Tapia, Martha; Briceño-Pérez, Carlos.
  • Reyna-Villasmil, Eduardo; Hospital Central Dr. Urquinaona. Servicio de Ginecología y Obstetricia. Maracaibo. VE
  • Mejía-Montilla, Jorly; La Universidad del Zulia. Facultad de Medicina. Maracaibo. VE
  • Reyna-Villasmil, Nadia; La Universidad del Zulia. Facultad de Medicina. Maracaibo. VE
  • Torres-Cepeda, Duly; Hospital Central Dr. Urquinaona. Servicio de Ginecología y Obstetricia. Maracaibo. VE
  • Rondón-Tapia, Martha; Hospital Central Dr. Urquinaona. Servicio de Ginecología y Obstetricia. Maracaibo. VE
  • Briceño-Pérez, Carlos; La Universidad del Zulia. Facultad de Medicina. Maracaibo. VE
Rev. chil. obstet. ginecol. (En línea) ; 86(3): 274-281, jun. 2021. ilus, tab
Article in Spanish | LILACS | ID: biblio-1388661
RESUMEN

OBJETIVO:

Comparar el índice de consistencia cervical con la longitud cervical en la predicción de parto pretérmino inminente en pacientes sintomáticas.

MÉTODO:

Estudio prospectivo realizado en mujeres con embarazos únicos entre 24 y 35 semanas, con diagnóstico clínico de amenaza de parto pretérmino, que asistieron al Hospital Central Dr. Urquinaona en Maracaibo, Venezuela. Al momento del diagnóstico, las pacientes fueron evaluadas con ecografía transvaginal para establecer los valores del índice de consistencia cervical y la longitud cervical. La resultante principal fue parto inminente (en los 7 días siguientes a la evaluación).

RESULTADOS:

Se incluyeron 657 pacientes, de las que 152 presentaron parto pretérmino inminente (grupo A) y 505 fueron consideradas como controles (grupo B). No se encontraron diferencias entre los grupos en cuanto a edad materna, nuliparidad, antecedente de parto pretérmino, antecedente de hábito tabáquico e índice de masa corporal. Las pacientes del grupo A presentaron valores significativamente más bajos del índice de consistencia cervical y de longitud cervical que las del grupo B (p < 0,0001). El índice de consistencia cervical mostró un valor de área bajo la curva de 0,857, mientras que para la longitud cervical este fue de 0,977. La diferencia de la capacidad de discriminación entre las áreas bajo la curva de cada prueba fue significativa (p < 0,0001).

CONCLUSIÓN:

El índice de consistencia cervical no es superior a la longitud cervical en la predicción de parto pretérmino inminente en pacientes sintomáticas.
ABSTRACT

OBJECTIVE:

To compare the cervical consistency index with the cervical length in predicting imminent preterm delivery in symptomatic patients.

METHOD:

This prospective study was conducted in women with single pregnancies between 24 and 35 weeks, with a clinical diagnosis of threatened preterm delivery who attended the Central Hospital Dr. Urquinaona, in Maracaibo, Venezuela. At the time of diagnosis, the patients were evaluated using transvaginal ultrasound to establish the values of the cervical consistency index and cervical length. The main result was imminent delivery (in the 7 days following the evaluation).

RESULTS:

657 patients were included, 152 women presented imminent preterm delivery (group A) and 505 were considered as controls (group B). No differences were found between the groups concerning maternal age, nulliparity, history of preterm delivery, history of smoking, and body mass index. Group A patients presented significantly lower values of cervical consistency index and cervical length compared to group B patients (p < 0.0001). The cervical consistency index and cervical length showed an area value under the curve of 0.857 and 0.977, respectively. The difference in the ability to discriminate between the areas under the curve of each test was significant (p < 0.0001).

CONCLUSIONS:

The cervical consistency index is not superior to the cervical length in the prediction of imminent preterm delivery in symptomatic patients.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Cervix Uteri / Obstetric Labor, Premature Type of study: Diagnostic study / Observational study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Pregnancy Language: Spanish Journal: Rev. chil. obstet. ginecol. (En línea) Journal subject: Ginecologia / Obstetr¡cia Year: 2021 Type: Article Affiliation country: Venezuela Institution/Affiliation country: Hospital Central Dr. Urquinaona/VE / La Universidad del Zulia/VE

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Cervix Uteri / Obstetric Labor, Premature Type of study: Diagnostic study / Observational study / Prognostic study / Risk factors Limits: Adult / Female / Humans / Pregnancy Language: Spanish Journal: Rev. chil. obstet. ginecol. (En línea) Journal subject: Ginecologia / Obstetr¡cia Year: 2021 Type: Article Affiliation country: Venezuela Institution/Affiliation country: Hospital Central Dr. Urquinaona/VE / La Universidad del Zulia/VE