Desempenho do teste de sentar e levantar de trinta segundos na população geriátrica da comunidade: um estudo transversal / Thirty second sit to stand test performance in community dwelling geriatric population: a cross-sectional study
Sheoran, Mehar; Vaish, Hina.
Affiliation
  • Sheoran, Mehar; Maharishi Markandeshwar Deemed to be University. Mullana-Ambala. IN
  • Vaish, Hina; Chhatrapati Shahu Ji Maharaj University. Kanpur. IN
Rev. Pesqui. Fisioter ; 12(1)jan., 2022. ilus, tab, graf
Article in En, Pt | LILACS | ID: biblio-1398477
Responsible library: BR333.2
RESUMO

INTRODUÇÃO:

Encontrar os valores de referência para o teste de sentar e levantar de 30 segundos e estudar a correlação das medidas antropométricas com o teste na população indiana geriátrica residente na comunidade. MATERIAL E

MÉTODOS:

136 indivíduos com idade >60 anos foram recrutados neste estudo transversal e observacional. O estudo foi realizado na Índia. Após a triagem inicial, as medidas antropométricas foram registradas. Em seguida, foi realizado o teste de sentar e levantar de 30 segundos.

RESULTADOS:

Os valores normais da década para o teste foram relatados como (média±DP) 60-70 anos (10,2±3,6), 71- 80 anos (9,5±3,4) e 81-90 anos (8,5±5,2). Idade, altura, circunferência da cintura e circunferência do quadril foram significativamente associadas aos valores do teste.

CONCLUSÃO:

Os valores normais para o teste de sentar e levantar de 30 segundos para a população geriátrica da comunidade foram relatados como média ± DP 10,0 ± 3,7. Os fatores antropométricos devem ser levados em consideração ao realizar o teste de sentar e levantar de 30 segundos em ambientes clínicos.
ABSTRACT

INTRODUCTION:

To find the reference values for the 30-second sit-to-stand test and study the correlation of anthropometric measures with the test in the communitydwelling geriatric Indian population. MATERIAL AND

METHODS:

136 individuals aged >60 years were recruited in this cross-sectional observational study. The study was conducted in India. After the initial screening, anthropometric measurements were recorded. Then, the 30-second sit-tostand test was conducted.

RESULTS:

Normal decade-wise values for the test were reported to be (mean ± SD) 60-70 years (10.2±3.6), 71-80 years (9.5±3.4), and 81-90 years (8.5±5.2). Age, height, waist circumference, and hip circumference were significantly associated with the 30-second sit-to-stand test values.

CONCLUSION:

Normal values for the test in the community-dwelling geriatric population were reported to be mean ± SD 10.0±3.7. Anthropometric factors should be taken into consideration when performing the 30-second sitto-stand test in clinical settings.
Subject(s)
Key words

Full text: 1 Index: LILACS Main subject: Geriatrics Type of study: Clinical_trials / Guideline / Risk_factors_studies Language: En / Pt Journal: Rev. Pesqui. Fisioter Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2022 Type: Article

Full text: 1 Index: LILACS Main subject: Geriatrics Type of study: Clinical_trials / Guideline / Risk_factors_studies Language: En / Pt Journal: Rev. Pesqui. Fisioter Journal subject: Farmacologia / Terapˆutica / Toxicologia Year: 2022 Type: Article