Your browser doesn't support javascript.
loading
Exclusión pilórica con dispositivo Ovesco (over-the-scope) en caso de fístula yeyunal en obstrucción duodenal de etiología maligna / Pyloric Exclusion with Ovesco (Over-the-scope-clip) Device for Jejunal Fistula in Duodenal Obstruction of Malignant Etiology
Pinilla-Morales,, Raúl Eduardo; Facundo-Navia,, Helena; Sánchez,, Elio Fabio; Jiménez-Lafourie,, Ivette C.; Sánchez-Hernández,, Álvaro Eduardo; Llorente-Portillo., Luis Carlos.
  • Pinilla-Morales,, Raúl Eduardo; Instituto Nacional de Cancerología. Bogotá. CO
  • Facundo-Navia,, Helena; Instituto Nacional de Cancerología. Bogotá. CO
  • Sánchez,, Elio Fabio; Universidad Militar Nueva Granada. Bogotá. CO
  • Jiménez-Lafourie,, Ivette C.; Universidad El Bosque. Bogotá. CO
  • Sánchez-Hernández,, Álvaro Eduardo; Universidad El Bosque. Bogotá. CO
  • Llorente-Portillo., Luis Carlos; Universidad del Norte. Barranquilla. CO
Rev. colomb. gastroenterol ; 37(3): 320-324, jul.-set. 2022. graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1408044
RESUMEN
Resumen Se reporta el caso de un hombre de 25 años con diagnóstico de tumor de células germinales no seminomatoso que ingresó a urgencias por cuadro clínico de dolor abdominal difuso asociado con distensión y múltiples episodios eméticos. Ante la sospecha clínica de obstrucción intestinal se realizó una tomografía abdominal contrastada que mostró una obstrucción en la tercera porción duodenal por compresión extrínseca ocasionada por múltiples conglomerados retroperitoneales. Se decidió el tiempo quirúrgico para una derivación gastrointestinal en la que se realizó una gastroyeyunoanastomosis por técnica convencional; hacia el quinto día posoperatorio presentó un deterioro clínico dado por episodios febriles, dolor abdominal y taquicardia. Se realizó una nueva tomografía abdominal que reportó una colección intraabdominal en el flanco izquierdo de 12 x 12 x 5 cm secundaria a proceso fistuloso yeyunal, se realizó un manejo de la colección con drenaje percutáneo por radiología intervencionista y alojamiento de catéteres de drenaje, y se realizó una esofagogastroduodenoscopia con el fin de ejecutar una técnica de exclusión pilórica con dispositivo Ovesco (over-the-scope) como manejo de la fístula yeyunal, con la que se obtuvo éxito técnico. Durante el posoperatorio se realizó como seguimiento una radiografía de vías digestivas que confirmó la no continuidad pilórica con adecuada permeabilidad de la gastroyeyunoanastomosis, y una tomografía abdominal contrastada que mostró una disminución de la colección intraabdominal sin extravasaciones del medio de contraste. El desenlace favorable de este caso sugiere la utilidad del dispositivo Ovesco en casos de fístulas del tracto gastrointestinal proximal, sobre todo en aquellos pacientes con múltiples comorbilidades o mal estado general que se favorecen de procedimientos mínimamente invasivos que disminuyan el riesgo de desenlace fatal.
ABSTRACT
Abstract A 25-year-old man diagnosed with a non-seminomatous germ cell tumor was admitted to the emergency department for diffuse abdominal pain associated with bloating and multiple emetic episodes. Due to the clinical suspicion of intestinal obstruction, a contrasted abdominal tomography was performed, showing an obstruction in the third duodenal portion resulting from extrinsic compression caused by multiple retroperitoneal conglomerates. Surgical time was scheduled for a gastric bypass surgery where gastrojejunostomy was performed using conventional technique. On the fifth postoperative day, he presented clinical deterioration due to febrile episodes, abdominal pain, and tachycardia. A new abdominal tomography was performed, reporting an intra-abdominal collection of pus on the left flank of 12 x 12 x 5 cm secondary to the jejunal fistula process. Hence, percutaneous drainage management of the collection was performed by interventional radiology and drainage catheter placement. In addition, an EGD was performed to conduct a pyloric exclusion technique with an Ovesco (over-the-scope-clip) device for managing the jejunal fistula, which was technically successful. A gastrointestinal tract X-ray was performed as a follow-up during the postoperative stage, showing no pyloric continuity with adequate patency of the gastrojejunostomy. In addition, a contrasted abdominal CT scan showed a decrease in the intra-abdominal collection without extravasation of the contrast medium. This case outcome suggests the Ovesco device may be helpful in proximal GI fistulas cases, especially in patients with multiple comorbidities or poor general conditions who may benefit from minimally invasive procedures decreasing the risk of fatal outcomes.


Full text: Available Index: LILACS (Americas) Type of study: Etiology study Language: Spanish Journal: Rev. colomb. gastroenterol Journal subject: Gastroenterology Year: 2022 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Nacional de Cancerología/CO / Universidad El Bosque/CO / Universidad Militar Nueva Granada/CO / Universidad del Norte/CO

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Type of study: Etiology study Language: Spanish Journal: Rev. colomb. gastroenterol Journal subject: Gastroenterology Year: 2022 Type: Article Affiliation country: Colombia Institution/Affiliation country: Instituto Nacional de Cancerología/CO / Universidad El Bosque/CO / Universidad Militar Nueva Granada/CO / Universidad del Norte/CO