Your browser doesn't support javascript.
loading
Estandarización de un procedimiento espectrofotométrico para la cuantificación de polisacárido capsular de Neisseria meningitidis serogrupo X / Standardization of a spectrophotometric procedure for the quantification of Neisseria meningitidis serogroup X capsular polysaccharide
Cardoso-San Jorge, Felix; Baró-Vinent, Bárbara; Hernández-Hernández, Marislen; Pedroso-Fernández, Jessy; Veréz-Bencomo, Vicente.
  • Cardoso-San Jorge, Felix; Instituto Finlay de Vacunas. La Habana. CU
  • Baró-Vinent, Bárbara; Instituto Finlay de Vacunas. La Habana. CU
  • Hernández-Hernández, Marislen; Instituto Finlay de Vacunas. La Habana. CU
  • Pedroso-Fernández, Jessy; Instituto Finlay de Vacunas. La Habana. CU
  • Veréz-Bencomo, Vicente; Instituto Finlay de Vacunas. La Habana. CU
Article in Spanish | LILACS, CUMED | ID: biblio-1410309
RESUMEN
En el presente trabajo se realiza la estandarización del procedimiento espectrofotométrico de determinación de polisacárido capsular e intermedios de Neisseria meningitidis serogrupo X, mediante la determinación de los grupos fosfodiéster presentes en su estructura, por el método de Chen. Se realizó un análisis de los siguientes criterios para la estandarización linealidad, precisión (repetibilidad y precisión intermedia) y exactitud. Se demostró mediante el diseño experimental y los procedimientos estadísticos empleados que el método es lineal (r > 0,99), el coeficiente de variación del factor respuesta < 5 por ciento, la desviación estándar relativa de la pendiente < 2 por ciento, no existiendo diferencia estadísticamente significativa entre el intercepto de la ecuación con respecto a cero; exacto, porque no existe diferencia estadísticamente significativa entre la concentración determinada en un material de trabajo y su concentración nominal; también demostró ser repetible, pues el coeficiente de variación de las concentraciones de la muestra evaluada (2,44; 2,43; 0,88 por ciento para las concentraciones bajas, medias y altas, respectivamente) es inferior al 3 por ciento y no existen diferencias estadísticamente significativas entre las medias de los resultados obtenidos por dos analistas, evaluados durante cuatro días a tres niveles de concentración. La precisión intermedia es satisfactoria(AU)
ABSTRACT
The present work comprises the standardization a spectrophotometric procedure for assessing Neisseria meningitidis, serogroup X capsular polysaccharide and their intermediates of modification, the phosphodiesters groups present in its structure, based on Chen method. An analysis of the following standardization criteria was performed linearity, precision (repeatability and intermediate precision) and accuracy. It was demonstrated through the experimental design and the statistical procedures used that the method is linear (r > 0.99), the coefficient of variation of the response factor < 5 percent, the relative standard deviation of the slope < 2 percent, with no statistically significant difference between the intercept of the equation with respect to zero; exact, because there is no statistically significant difference between the concentration determined in a work material and its nominal concentration; it also proved to be repeatable, because the coefficient of variation of the concentrations of the sample (2.44; 2.43; 0.88 percent for low, medium and high concentrations respectively) is less than 3 percent and there is no statistically significant difference between the means of the results obtained by two analysts, evaluated for four days at three concentration levels. Its intermediate precision was satisfactory(AU)
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Reference Standards / Spectrophotometry / Virulence Factors / Meningococcal Infections Limits: Female / Humans / Male Language: Spanish Journal: Vaccimonitor (La Habana, Print) Journal subject: Molecular Biology / Epidemiology / Microbiology / Vacinas Year: 2022 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Finlay de Vacunas/CU

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Reference Standards / Spectrophotometry / Virulence Factors / Meningococcal Infections Limits: Female / Humans / Male Language: Spanish Journal: Vaccimonitor (La Habana, Print) Journal subject: Molecular Biology / Epidemiology / Microbiology / Vacinas Year: 2022 Type: Article Affiliation country: Cuba Institution/Affiliation country: Instituto Finlay de Vacunas/CU