Índice de PaO2/FAO2: ¿un mejor indicador de oxigenación para valorar la hipoxemia? Resultados de un análisis de concordancia con el índice de PaO2/FiO2 / PaO2/FAO2 index: a better oxygenation indicator to assess hypoxemia? Results of an analysis of agreement with the PaO2/FiO2 index / Índice PaO2/FAO2: melhor indicador de oxigenação para avaliar hipoxemia? Resultados de uma análise de concordância com o índice de PaO2/FiO2
Rojas Corona, Lizeth; Vidal Andrade, Erick; Cerón Díaz, Ulises W.
  • Rojas Corona, Lizeth; Universidad Nacional Autónoma de México. MX
  • Vidal Andrade, Erick; Hospital Español. MX
  • Cerón Díaz, Ulises W; Hospital Español. MX
Med. crít. (Col. Mex. Med. Crít.) ; 37(1): 21-25, Feb. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1521185
RESUMEN
Resumen: Introducción: el cociente PaO2/FiO2 ajustado a la presión barométrica se utiliza para evaluar la oxigenación en la falla respiratoria; sin embargo, no toma en cuenta la PaCO2, a diferencia del índice PaO2/FAO2 (PaO2 dividida entre la fracción alveolar de oxígeno). Objetivo: evaluar la concordancia entre PaO2/FiO2 y PaO2/FAO2. Material y métodos: estudio observacional, ambispectivo, transversal y analítico en pacientes mayores de 18 años, bajo ventilación mecánica invasiva, con falla respiratoria hipoxémica y con diferentes valores de PaCO2. Resultados: se analizó la concordancia en 64 mediciones gasométricas tomadas al ingreso y cuando se documentó la mayor PaCO2 de 32 enfermos. El análisis de Bland y Altman mostró una media de las diferencias (bias) de 13 y un límite de concordancia de 95%, entre 54 y -24. La concordancia es mejor cuando la PaO2/FiO2 es menor de 150. Veintidós por ciento de las mediciones no concordaron en la asignación a grupos con hipoxemia leve, moderada o grave. Conclusiones: existe una moderada concordancia entre la PaO2/FAO2 y la PaO2/FiO2; sin embargo, en los enfermos con hipoxemia severa la concordancia es mejor. En los pacientes con PaO2/FiO2 ≥ 150, la hipercapnia explica en parte la baja concordancia. Posiblemente la PaO2/FAO2 es una mejor forma de evaluar el grado del trastorno en la oxigenación.
ABSTRACT
Abstract: Introduction: the PaO2/FiO2 ratio adjusted to barometric pressure is used to assess oxygenation in respiratory failure; however, it does not take PaCO2 into account, unlike the PaO2/FAO2 ratio (PaO2 divided by the alveolar fraction of oxygen). Objective: to evaluate the agreement between PaO2/FiO2 and PaO2/FAO2. Material and methods: observational, ambispective, cross-sectional and analytical study in patients older than 18 years, under invasive mechanical ventilation with respiratory failure and with different PaCO2 values. Results: agreement was analyzed in 64 gasometric measurements taken at admission and when the highest PaCO2 was documented, of 32 patients. The Bland and Altman analysis showed a mean of the differences (bias) of 13 and a 95% limit of agreement, between 54 and -24. Agreement is better when PaO2/FiO2 is greater than 150. Twenty two percent of the measurements did not agree in the assignment to groups with mild, moderate, or severe hypoxemia. Conclusions: there is moderate agreement between PaO2/FAO2 and PaO2/FiO2; however, in patients with severe hypoxemia, agreement is better. In patients with PaO2/FiO2 ≥ 150, hypercapnia partly explains the low agreement. PaO2/FAO2 is possibly a better way to assess the degree of oxygenation disturbance.
RESUMO
Resumo: Introdução: o cociente PaO2/FiO2 ajustado à pressão barométrica é utilizada para avaliar a oxigenação na insuficiência respiratória; entretanto, não considera a PaCO2, ao contrário da relação PaO2/FAO2 (PaO2 dividida pela fração alveolar de oxigênio). Objetivo: Avaliar a concordância entre PaO2/FiO2 e PaO2/FAO2. Material e métodos: estudo observacional, ambispectivo, transversal e analítico em pacientes maiores de 18 anos, sob ventilação mecânica invasiva com insuficiência respiratória hipoxêmica e com diferentes valores de PaCO2. Resultados: analisou-se a concordância em 64 gasometrias feitas na admissão e quando documentou-se a maior PaCO2, de 32 pacientes. A análise de Bland e Altman mostrou uma média das diferenças (bias) de 13 e limite de concordância de 95%, entre 54 e -24. A concordância é melhor quando a PaO2/FiO2 é maior que 150. 22% das medidas não concordaram na alocação dos grupos com hipoxemia leve, moderada ou grave. Conclusões: existe uma concordância moderada entre PaO2/FAO2 e a PaO2/FiO2; no entanto, em pacientes com hipoxemia grave a concordância é melhor. Em pacientes com PaO2/FiO2 ≥ 150, a hipercapnia explica em parte a baixa concordância. Possivelmente a PaO2/FAO2 seja a melhor forma de avaliar o grau de distúrbio da oxigenação.


Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Med. crít. (Col. Mex. Med. Crít.) Journal subject: Cirurgia Geral / Oftalmologia / Ortopedia Year: 2023 Type: Article Affiliation country: Mexico Institution/Affiliation country: Hospital Español/MX / Universidad Nacional Autónoma de México/MX

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Med. crít. (Col. Mex. Med. Crít.) Journal subject: Cirurgia Geral / Oftalmologia / Ortopedia Year: 2023 Type: Article Affiliation country: Mexico Institution/Affiliation country: Hospital Español/MX / Universidad Nacional Autónoma de México/MX