Your browser doesn't support javascript.
loading
Estudio in vitro del ajuste de supraestructuras pasivadas sobre implantes múltiples / In vitro study of the adjustment of passivated suprastructures on multiple implants
Boero López, Edgardo; Albera, Juan Carlos.
Affiliation
  • Boero López, Edgardo; Universidad Nacional de Cuyo. Facultad de Odontología. Cátedra de Clínica de Prótesis Completa.
  • Albera, Juan Carlos; Universidad Nacional de Cuyo. Facultad de Odontología. Carrera de Especialización en Prostodoncia.
Rev. Asoc. Odontol. Argent ; 111(3): 3-3, dic. 2023. graf
Article in Es | LILACS-Express | LILACS | ID: biblio-1550643
Responsible library: AR1.1
RESUMEN
Resumen Objetivo Comparar dos procedimientos de soldadura convencionales empleando una aleación de Cr-Co, para conectar barras coladas seccionadas a ser fijadas sobre implantes. Materiales y métodos A partir de un modelo maestro que representa un maxilar desdentado con cuatro implantes, se confeccionaron veinte (n=20) probetas seccionadas en tres partes. Se conformaron dos grupos, cada uno con diez (n=10) ejemplares. Una vez acondicionadas, fueron atornilladas al modelo maestro. Su desajuste inicial se analizó utilizando una lupa estereoscópica, con una cámara incorporada y un software. Las partes fueron soldadas empleando un procedimiento diferente para cada grupo. Las correspondientes al Grupo I se invistieron en un block refractario a base de sílico-fosfato. Las del Grupo II se montaron en una estructura metálica Clever Spider. El desajuste fue mensurado y los resultados procesados estadísticamente. El nivel de significación fue establecido en p<0,05. Resultados El Grupo I tuvo un desajuste inicial de 97,30±13,81μm y el Grupo II de 98,53±11,24μm. Luego de la soldadura, el Grupo I registró 98,53±17,17μm, 1,23μm mayor respecto al inicial. En el Grupo II se observó 103,13±17,61μm, 4,60μm por encima del original. Se analizaron mediante prueba t de Student; en ambos casos el resultado fue de p>0,05. Al comparar entre sí los grupos I y II, por medio de la prueba t y de comprobación no paramétrica de Mann-Whitney, se observaron diferencias no significativas, p=0,41 y p=0,38 respectivamente. Conclusiones Bajo las condiciones de este estudio, se observó que los dos métodos de soldadura analizados fueron confiables para unir supraestructurasos metálicas sin que se afecte su ajuste final.
ABSTRACT
Abstract Aim Compare two conventional welding procedures using a Cr-Co alloy, to connect sectioned cast bars to be fixed on implants. Materials and methods From a master model representing a toothless jaw with four implants, twenty (n=20) specimens sectioned into three parts were made. Two groups were formed, each with ten (n=10) specimens. Once conditioned, they were screwed to the master model. Its initial mismatch was analyzed using a stereoscopic magnifier, with a built-in camera and a software. The parts were welded using a different procedure for each group. Those corresponding to Group I were invested in a refractory block based on silyl-phosphate. Those of Group II were mounted on a Clever Spider metal structure. The mismatch was measured, and the results processed statistically. The level of significance was established at p<0.05. Results Group I had an initial mismatch of 97.30 ±13.81μm, and Group II of 98.53±11.24μm. After welding, Group I registered 98.53±17.17μm, 1.23μm higher than the initial one. In Group II, 103.13±17.61μm was observed, 4.60μm above the original. They were analyzed using Student's t test; in both cases the result was p>0.05. When comparing groups I and II, using the t-test and the Mann-Whitney nonparametric verification, non-significant differences were observed, p=0.41 and p=0.38 respectively. Conclusions Under the conditions of this study, it was observed that the two welding methods analyzed were reliable for joining metallic superstructures without affecting their final fit.
Key words

Full text: 1 Index: LILACS Language: Es Journal: Rev. Asoc. Odontol. Argent Journal subject: ODONTOLOGIA Year: 2023 Type: Article

Full text: 1 Index: LILACS Language: Es Journal: Rev. Asoc. Odontol. Argent Journal subject: ODONTOLOGIA Year: 2023 Type: Article