Your browser doesn't support javascript.
loading
Estenosis tricuspídea de bioprótesis tratada mediante implante valvular percutáneo: una solución segura para un paciente inusual
Barria, Alberto; Chaigneau, Ernesto; Zamorano, Jaime.
  • Barria, Alberto; s.af
  • Chaigneau, Ernesto; s.af
  • Zamorano, Jaime; s.af
Rev. méd. Chile ; 151(6)jun. 2023.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1560241
RESUMEN
Se comunica el caso de una mujer de 31 años quien había sido previamente sometida a reemplazo valvular aórtico, mitral y tricuspídeo en tres episodios quirúrgicos. Fue ingresada a nuestra sección de cardiologÍa con síntomas compatibles con insuficiencia cardiaca derecha. Se efectuó evaluación mediante ecocardiograma, sondeo cardíaco derecho/izquierdo, angioTAC cardíaco y cardio resonancia. Se diagnosticó una estenosis tricuspídea severa secundaria a disfunción de prótesis biológica. Debido a alto riesgo operatorio y riesgo de falla ventricular derecha post-operatorio, la paciente fue rechazada para reemplazo valvular quirúrgico. Se decidió efectuar reemplazo tricuspídeo procedimiento "valve in valve". Se logró efectuar de manera exitosa por abordeje venoso femoral, prótesis balón expansible. Se demostró corrección de la estenosis tricuspídea y la paciente evolucionó con remisión de los síntomas de falla cardíaca.
ABSTRACT
We report a 31-year-old woman who was previously subjected to aortic, mitral, and tricuspid valve replacement in three different surgical episodes. She was admitted to our cardiology section with acute right heart failure symptoms. She was studied by echocardiography, right/left heart catheterization, cardiac CT scan and cardiac magnetic resonance. A severe tricuspid stenosis due to biological prosthesis dysfunction was diagnosed. Due to high operative risk and risk of postoperative right ventricular failure, the patient was rejected for cardiovascular surgery. We decided on a percutaneous tricuspid "valve in valve replacement". The procedure was done successfully by venous femoral approach, with a balloon expandable prosthesis. Tricuspid stenosis was corrected and the patient evolved with remission of heart failure symptoms.

Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2023 Type: Article

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Language: Spanish Journal: Rev. méd. Chile Journal subject: Medicine Year: 2023 Type: Article