Your browser doesn't support javascript.
loading
Respostas hemodinâmicas durante e após sessão de pilates em comparação com exercício aeróbico e resistido / Hemodynamic response during and after pilates session in comparison of aerobic and resistance exercise
Meneses Junior, Jordane; Gomes, Jorge; Gomes, Jose; Amaral, Mara; Madruga, Renata; Silva, Thamires; Brito, Aline.
  • Meneses Junior, Jordane; Universidade Federal da Paraíba. João Pessoa. BR
  • Gomes, Jorge; Universidade Federal de Pernambuco. Recife. BR
  • Gomes, Jose; Universidade Federal da Paraíba. João Pessoa. BR
  • Amaral, Mara; Universidade Federal da Paraíba. João Pessoa. BR
  • Madruga, Renata; Universidade Federal da Paraíba. João Pessoa. BR
  • Silva, Thamires; Universidade Federal da Paraíba. João Pessoa. BR
  • Brito, Aline; Universidade Federal da Paraíba. João Pessoa. BR
Rev. bras. ativ. fís. saúde ; 19(6): 732-743, nov. 2014. fig
Article in Portuguese | LILACS | ID: biblio-339
RESUMO
Os objetivos foram verificar a segurança da sessão Pilates (SP) por meio do duplo produto e comparar a hipotensão (HPE) com uma sessão aeróbia (SA) e treinamento resistido (SR) em adultos jovens analisando as alterações e comportamento hemodinâmico advindo durante as sessões. 12 adultos jovens do sexo masculino (23,3 ± 2 anos; 23,9 ± 1 Kg/m²) realizaram três sessões exercícios SA, SR e SP e uma sessão controle (SC) (60 minutos cada). A pressão arterial (PA) e a frequência cardíaca (FC) foram registradas em repouso, durante e após as sessões a cada 15 minutos durante as sessões SP, SA e SC, e a cada dois exercícios em SR. Após a sessão foram mensuradas a cada 15 minutos até 60 minutos. Os dados foram analizados pelos testes ANOVA One-way (intragrupo) com Post Hoc de Bonferroni e ANOVA Two-way (intergrupo) com post hoc de Newman-Keuls. O duplo produto foi calculado (FC x PAS). Os resultados das sessões de exercício elevaram significativamente o duplo-produto com valores médios próximos a 25,000±1670, 16,000±3400 e 14,000±1420 mmHg.bpm respectivamente para SA, SR e SP. Refletiram em HPE sistólica significativas aos 15, 30, 45 e 60 minutos em SA. Aos 45 e 60 minutos em SR, e SP não produziu reduções significativas apresentando reduções dos componentes sistólicos de 4±4 a 6±3 mmHg. Nenhuma sessão produziu alteração HPE diastólica. SP com menores magnitudes apresentou valores médios entre 2 ± 4 a 4 ± 2 mmHg. Entretanto as HPEs não apresentaram diferenças significativas entre as mesmas. Conclui-se que SP apresenta comportamento hemodinâmico seguro em adultos jovens por permanecer abaixo da faixa máxima estabelecida (≤30.000mmHg). Apesar de não observar resultados significativos na HPE, apresenta comportamento hemodinâmico semelhante a SA e SR.
ABSTRACT
The objectives were to verify the safety of the Pilates Session (SP) through the double product and to compare the hypotension (PEH) with an aerobic (SA) and resistance (RS) session in young adults by analyzing the changes and hemodynamic behavior during sessions. 12 young male adults (23.3 ± 2 years; 23.9 ± 1 kg / m²) performed three exercise sessions SA, RS and SP and control session (SC) (60 minutes each). Blood pressure (BP) and heart rate (HR) were recorded at rest, during and after the sessions every 15 minutes during the SP, SA and SC sessions and every two exercises in RS. After the session measured by every 15 minutes until 60 minutes. The data were analyze by One-Way ANOVA with Bonferroni's post hoc test (intragroup) and Two-Way ANOVA (intergroup) with Newman-Keuls's post hoc test. The double product was calculated (HR x SBP). The results shows the exercise sessions significantly increased the double-product with an average of values near the 25,000±1670, 16,000±3400 e 14,000±1420 mmHg.bpm respectively for SA, RS and SP. Reflected in significant difference at 15, 30, 45 and 60 minutes in SA systolic PEH. At 45 and 60 minutes in RS and SP did not produced, showing reductions of systolic components 4±4 a 6±3 mmHg. The sessions produced no statistical changes in diastolic HPE. SP with smaller magnitudes showed with average values between 2±4 a 4±2mmHg. However the HPE's were not statistical different between them. Therefore, SP is safe hemodynamically in young adults to remain below the maximum established range (≤30.000mmHg). Although were not observed significant results in HPE, shows a similar hemodynamic behavior in comparison to SA and RS.
Subject(s)

Full text: Available Index: LILACS (Americas) Main subject: Exercise / Resistance Training / Post-Exercise Hypotension / Arterial Pressure Limits: Adult / Humans / Male Language: Portuguese Journal: Rev. bras. ativ. fís. saúde Journal subject: Sports Medicine Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal da Paraíba/BR / Universidade Federal de Pernambuco/BR

Similar

MEDLINE

...
LILACS

LIS

Full text: Available Index: LILACS (Americas) Main subject: Exercise / Resistance Training / Post-Exercise Hypotension / Arterial Pressure Limits: Adult / Humans / Male Language: Portuguese Journal: Rev. bras. ativ. fís. saúde Journal subject: Sports Medicine Year: 2014 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal da Paraíba/BR / Universidade Federal de Pernambuco/BR