Dynamometry for the measurement of grip, pinch, and trunk muscles strength in subjects with subacute stroke: reliability and different number of trials
Aguiar, Larissa T; Martins, Júlia C; Lara, Eliza M; Albuquerque, Julianna A; Teixeira-Salmela, Luci F; Faria, Christina D. C. M.
  • Aguiar, Larissa T; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
  • Martins, Júlia C; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
  • Lara, Eliza M; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
  • Albuquerque, Julianna A; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
  • Teixeira-Salmela, Luci F; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
  • Faria, Christina D. C. M; Universidade Federal de Minas Gerais. Escola de Educação Física, Fisioterapia e Terapia Ocupacional. Belo Horizonte. BR
Braz. j. phys. ther. (Impr.) ; 20(5): 395-404, Sept.-Oct. 2016. tab
Article in English | LILACS | ID: biblio-828291
ABSTRACT
ABSTRACT Background Muscle strength is usually measured in individuals with stroke with Portable dynamometers (gold standard). However, no studies have investigated the reliability, the standard error of measurement (SEM) and the minimal detectable difference (MDD95%) of the dynamometry for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke. Objective 1) To investigate the intra and inter-rater reliability, the SEM and the MDD95% of the portable dynamometers for the measurement of grip, pinch and trunk strength in subjects with subacute stroke, and 2) to verify whether the use of different number of trials (first trial and the average of the first two and three trials) affected the results. Method 32 subjects with subacute stroke (time since stroke onset 3.6 months, SD=0.66 months) were evaluated. Hand grip, 3 pinch grips (i.e. pulp-to-pulp/palmar/lateral) and 4 trunk muscles (i.e. flexors, extensors, lateral flexors and rotators) strength were bilaterally assessed (except trunk flexors/extensors) with portable dynamometry by two independent examiners over two sessions (1-2 weeks apart). One-way ANOVAs and intraclass correlation coefficients (ICC2,k) were used for analysis (α=0.05). SEM and MDD95% were also calculated. Results For all muscular groups and sources of outcome values, including one trial, after familiarization, similar results were found (0.01≤F≤0.08; 0.92≤p≤0.99) with significant and adequate values of intra-rater (0.64≤ICC≤0.99; 0.23≤95%CI≤0.99) and inter-rater (0.66≤ICC≤0.99; 0.25≤95%CI≤0.99) reliability. SEM and MDD95% were considered low (0.39≤EPM≤2.21 Kg; 0.96≤MMD95%≤6.12 Kg) for all outcome scores. Conclusion Only one trial, following familiarization, demonstrated adequate intra-rater and inter-rater reliability of the portable dynamometers for the measurement of hand grip, pinch grip and trunk strength in subjects with subacute stroke.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Muscle, Skeletal / Hand Strength / Stroke / Muscle Strength / Stroke Rehabilitation Limits: Humans Language: English Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Muscle, Skeletal / Hand Strength / Stroke / Muscle Strength / Stroke Rehabilitation Limits: Humans Language: English Journal: Braz. j. phys. ther. (Impr.) Journal subject: MEDICINA FISICA E REABILITACAO Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal de Minas Gerais/BR