Your browser doesn't support javascript.
loading
Estabelecimento de uma proporção entre largura de dentes artificiais anteriores, medidos em curva e em linha reta / Establishing a ratio between the width of anterior artificial teeth measured in curved and straight configurations
Almeida, Thalyta Apuhena de Oliveira; Aguiar, Gerlayne Barros de; Assunção e Souza, Rodrigo Othávio de; Carreiro, Adriana da Fonte Porto.
  • Almeida, Thalyta Apuhena de Oliveira; Universidade Federal do Rio Grande do Norte. Depto. de Odontologia. Natal. BR
  • Aguiar, Gerlayne Barros de; s.af
  • Assunção e Souza, Rodrigo Othávio de; Universidade Federal do Rio Grande do Norte. Depto. de Odontologia. Natal. BR
  • Carreiro, Adriana da Fonte Porto; Universidade Federal do Rio Grande do Norte. Depto. de Odontologia. BR
PróteseNews ; 3(4): 436-442, out.-dez. 2016. ilus, tab
Article in Portuguese | LILACS, BBO | ID: biblio-837410
RESUMO

Objetivo:

estabelecer uma proporção única de redução entre a medida da largura dos seis dentes artificiais anteriores superiores, em curva e em linha reta. Material e

métodos:

foi utilizado um dispositivo pré-fabricado, simulando o plano de cera superior, no qual foram montados os dentes (Premium, Heraeus-Kulzer Inc. ­ Hanau, Alemanha) nos seguintes modelos T2, O2, R2, S2, S4, O4, S6, R4, R6, T4 e T6. Em seguida, a largura em curva entre os dentes anteriores montados foi medida com uma régua flexível, tendo como referência a face distal dos caninos. A partir dos dados obtidos (mm) e dos valores das medidas fornecidos na carta molde do fabricante, realizou-se o cálculo da proporção entre essas duas medidas para cada modelo de dentes.

Resultados:

verificou-se redução entre a medida em curva e a medida em linha reta, variando de 4% a 19% para todos os tipos de modelos estudados. Assim, não foi possível estabelecer uma porcentagem padrão única de redução para todos os tipos de dentes do fabricante. Porém, agrupando-se a redução em milímetros, observou-se uma redução variável entre os modelos em curva e em linha reta 2 mm para o modelo T2; 3 mm para os modelos O2, R2, S2 e S4; 4 mm para os modelos O4 e S6; 5 mm para os modelos R4, R6 e T4; e 9 mm para o modelo T6.

Conclusão:

é possível estabelecer uma redução aproximada (em mm) entre uma medição em curva e reta na seleção de dentes artificiais Premium/Heraeus-Kulzer.
ABSTRACT

Objective:

this study aimed to establish a single rate reduction between the measurement of the width of the six artificial anterior upper teeth, in curved and straight configurations.

Methods:

for this, a prefabricated device simulating the upper wax rim was used and received artificial teeth (Premium, Heraeus-Kulzer Inc., Hanau, Germany) from T2, O2, R2, S2, S3, O4, S6, R4, R6, T4, and T6. Next, the width of the six anterior teeth in curvature was measured from the distal of both canines. After, based on the mold chart of the manufacturer, the ratio between the straight and curved configurations was generated.

Results:

there was a 4% to 19% in reduction between the curved and straight configurations. A single reduction percentage was not obtained for all tooth forms. However, the reductions were 2 mm for T2, 3 mm for O2, R2, S2 and S4; 4 mm for O4 and S6; 5 mm for R4, R6, and T4; and 9 mm for T6 models.

Conclusion:

it is possible to establish an approximated reduction (in mm) between the curved and straight configurations for Premium/Heraeus-Kulzer artificial teeth.
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Tooth, Artificial / Dental Prosthesis / Esthetics, Dental Type of study: Prognostic study Limits: Humans Language: Portuguese Journal: PróteseNews Journal subject: Est‚tica Dent ria / Implanta‡Æo Dent ria / Pr¢tese Periodontal Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Norte/BR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Tooth, Artificial / Dental Prosthesis / Esthetics, Dental Type of study: Prognostic study Limits: Humans Language: Portuguese Journal: PróteseNews Journal subject: Est‚tica Dent ria / Implanta‡Æo Dent ria / Pr¢tese Periodontal Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: Universidade Federal do Rio Grande do Norte/BR