Substitutos ósseos sintéticos na Implantodontia / Synthetic bone substitutes for Implant Dentistry ­ a literature review
Dantas, Felipe Torres; Martins, Sérgio Henrique Lago; Irie, Milena Suemi; Bastos, Gabriel Figueiredo; Souza, Sérgio Luís Scombatti de.
  • Dantas, Felipe Torres; s.af
  • Martins, Sérgio Henrique Lago; s.af
  • Irie, Milena Suemi; s.af
  • Bastos, Gabriel Figueiredo; s.af
  • Souza, Sérgio Luís Scombatti de; USP. Faculdade de Odontologia de Ribeirão Preto. Depto. de CTBMF e Periodontia. Ribeirão Preto. BR
ImplantNewsPerio ; 1(1): 97-103, jan.-fev. 2016.
Article in Portuguese | LILACS, BBO | ID: biblio-847000
RESUMO

Objetivo:

analisar sistematicamente, na literatura científica, o uso de substitutos ósseos sintéticos na regeneração óssea para Implantodontia. Material e

métodos:

uma busca foi realizadas nas bases de dados PubMed, Cochrane, LILACS e SciELO, nos últimos quinze anos, combinando as palavras-chave "regeneração óssea", "materiais biocompatíveis", "implantes dentários", e "materiais aloplásticos".

Resultados:

Dos 199 artigos inicialmente recuperados, apenas 27 foram selecionados, incluindo revisões sistemáticas/ metanálises (n=2), revisões da literatura (n=1), estudos clínicos (n=9) e pré-clínicos (n=12), relato de caso (n=1) e tese (n=1). Nos modelos animais, o vidro bioativo é capaz de provocar formação óssea à distância, inibir a migração apical do epitélio juncional, e gerar maior deposição de cemento na superfície radicular. Partículas esféricas geram melhor dissolução e integração com o novo osso circundante, e bons resultados são vistos nas técnicas de ROG e RTG. Em um estudo clínico randomizado, o vidro bioativo misturado ao osso autógeno para regeneração de defeitos intraósseos reduziu significativamente a profundidade de sondagem, com ganho de nível clínico de inserção, e resolução dos defeitos já aos seis meses. Nos modelos animais, a tríade hidroxiapatita (HA), beta-fosfato tricálcio (ß-TCP), e fosfato de cálcio bifásico (HA+ ß-TCP) tem se mostrado biocompatível, biorreabsorvível e osteocondutora. Um estudo clínico controlado com HA+ ß-TCP/ membrana revelou melhor preservação óssea vertical e horizontal comparado ao coágulo/membrana, nas TCFCs de seis meses. Regenerações ósseas verticais significativas com estes materiais sintéticos são potencializadas pelo uso dos fatores de crescimento.

Conclusão:

substitutos ósseos sintéticos demonstram uso promissor para regeneração. Entretanto, a evidência clínica deve ser substancialmente aumentada.
ABSTRACT

Objective:

to systematically analyze in the scientifi c literature the use of synthetic bone substitutes for bone regeneration in implant dentistry. Material and

methods:

a search was conducted at the PubMed, Cochrane, LILACS and SciELO databases considering the last fi fteen years, and combining the keywords "bone regeneration", "biocompatible materials", "dental implants", and "alloplastic materials".

Results:

of the 199 articles initially retrieved, only 27 were selected, including systematic reviews/meta-analysis (n=2), literature reviews (n=1), clinical (n=9) and pre-clinical (n=12) studies, case report (n=1) and thesis (n=1). In animal models, the bioactive glass can cause bone formation at distance, inhibit apical migration of the junctional epithelium, and generate greater deposition of cementum over the root surface. Spherical particles generate better dissolution and integration with the new surrounding bone, and good results are seen in the ROG and RTG techniques. In a randomized study, the bioactive glass mixed with autogenous bone to regenerate intra-osseous defects signifi cantly reduced probing depths, with clinical attachment level gains, and defect resolution as early as 6 months. In animal models, the triad hydroxyapatite (HA), beta-tricalcium phosphate (ß-TCP), and biphasic calcium phosphate (HA + ß-TCP) has been shown to be biocompatible, bioresorbable, and osteoconductive. A controlled clinical study with (HA + ß-TCP/membrane) showed better vertical and horizontal bone preservation compared to clot / membrane at the 6 month CBCT images. Also, signifi cant vertical bone regeneration with these synthetic materials is enhanced by the use of growth factors.

Conclusion:

the synthetic bone substitutes are good candidates for regeneration. However, the level of clinical evidence must be substantially increased.
Subject(s)

Search on Google
Index: LILACS (Americas) Main subject: Biocompatible Materials / Bone Regeneration / Dental Implants / Bone Substitutes / Growth Differentiation Factors Type of study: Controlled clinical trial / Prognostic study / Systematic reviews Limits: Humans Language: Portuguese Journal: ImplantNewsPerio Journal subject: Odontologia Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: USP/BR

Similar

MEDLINE

...
LILACS

LIS

Search on Google
Index: LILACS (Americas) Main subject: Biocompatible Materials / Bone Regeneration / Dental Implants / Bone Substitutes / Growth Differentiation Factors Type of study: Controlled clinical trial / Prognostic study / Systematic reviews Limits: Humans Language: Portuguese Journal: ImplantNewsPerio Journal subject: Odontologia Year: 2016 Type: Article Affiliation country: Brazil Institution/Affiliation country: USP/BR