Your browser doesn't support javascript.
loading
Avaliação dos parâmetros pressóricos intra-abdominal e pulmonar em pacientes submetidos à abdominoplastia / Evaluation of pressure parameters intra-abdominal and thoracic in patients submitted to abdominoplasty
Amaral, Jefferson Di Lamartine Galdino; Soares, Daniel Augusto dos Santos; Oliveira Junior, Juldasio Galdino de; Daher, Leonardo Martins Costa; Moura, Luciano Gomes; Andarade, Fernando Cassio de; Rebonatto, Edinei Fabiano; Daher, José Carlos.
  • Amaral, Jefferson Di Lamartine Galdino; Sociedade Brasileira de Cirurgia Plástica. Hospital Daher Lago Sul. São Paulo, SP; Brasilia, DF. BR
  • Soares, Daniel Augusto dos Santos; Hospital Daher Lago Sul. Brasília, DF. BR
  • Oliveira Junior, Juldasio Galdino de; Sociedade Brasileira de Cirurgia Plástica. Hospital Daher Lago Sul. São Paulo, SP; Brasilia, DF. BR
  • Daher, Leonardo Martins Costa; Hospital Daher Lago Sul. Brasília, DF. BR
  • Moura, Luciano Gomes; Hospital Daher Lago Sul. Brasília, DF. BR
  • Andarade, Fernando Cassio de; Sociedade Brasileira de Anestesiologia. Hospital São Francisco. Rio de Janeiro, RJ; Ceilândia, DF. BR
  • Rebonatto, Edinei Fabiano; Sociedade Brasileira de Anestesiologia. Hospital São Francisco. Rio de Janeiro, RJ; Ceilândia, DF. BR
  • Daher, José Carlos; Sociedade Brasileira de Cirurgia Plástica. Hospital Daher Lago Sul. São Paulo, SP; Brasilia, DF. BR
Rev. bras. cir. plást ; 32(2): 231-236, 2017. ilus, tab
Article in English, Portuguese | LILACS | ID: biblio-847372
RESUMO

Introdução:

O abdome é um segmento estético-funcional importante na caracterização do contorno corporal. A confecção da plicatura do reto abdominal pode ocasionar diversos transtornos como o aumento da pressão intra-abdominal e torácica. Assim, este estudo tem como objetivo avaliar os parâmetros de pressão abdominal e pulmonar em pacientes submetidos à abdominoplastia com lipoaspiração.

Métodos:

Estudo longitudinal prospectivo descritivo. As pacientes foram submetidas à lipoabdominoplastia com lipoaspiração de flancos pelo mesmo cirurgião plástico sênior. A mensuração da pressão intra-abdominal foi feita por meio do uso de um dispositivo acoplado à sonda vesical de demora do paciente e a pressão intratorácica foi aferida por meio do monitor do aparelho de ventilação. As medições foram feitas antes e após a plicatura e durante a posição de Fowler.

Resultados:

O tempo médio do ato operatório foi de 4 horas e 8 minutos. A pressão intra-abdominal antes e após a plicatura do músculo reto abdominal variou de 2 a 11 cm H2O e 5 a 16 cm H2O, respectivamente. A pressão intratorácica antes e após a plicatura do músculo reto abdominal variou de 13 a 17 cm H2O e 14 a 18 cm H2O, respectivamente. A pressão intra-abdominal em posição de Fowler variou de 6 a 23 cm H2O. A pressão intratorácica em posição de Fowler variou de 15 a 19 cm H2O. Foi observado um caso de deiscência, um caso de seroma e um caso de desconforto respiratório.

Conclusão:

Os resultados elucidam que a plicatura do reto abdominal ocasiona o aumento da pressão intra-abdominal e pulmonar sem gerar alterações sistêmicas significativas.
ABSTRACT

Introduction:

The abdomen is an important aesthetic and functional segment in the characterization of body contouring. The plication of the rectus abdominis may cause various problems to the patient such as increased intra-abdominal and thoracic pressure. Thus, this study aims to evaluate abdominal pressure and pulmonary parameters in patients undergoing abdominoplasty with liposuction.

Methods:

This is a descriptive longitudinal prospective study. All patients underwent the lipoabdominoplasty with liposuction of flanks by the same senior plastic surgeon. The intra-abdominal pressure was measured by a device attached to indwelling urinary catheter of the patient and intra-thoracic pressure was measured by the ventilation device monitor. Measurements were made before and after plication and in Fowler's position.

Results:

Mean surgery time was 4 hours and 08 minutes. Intra-abdominal pressure before and after plication of the rectus abdominis ranged from 2 to 11 cm H2O and 5-16 cm H2O, respectively. Intra-thoracic pressure before and after plication of the rectus abdominis ranged from 13 to 17 cm H2O and 14-18 cm H2O respectively. The intra-abdominal pressure in Fowler's position ranged from 6 to 23 cm H2O. The intra-thoracic pressure in Fowler's position ranged from 15 to 19 cm H2O. One case of small dehiscence, one case of seroma and one case of respiratory distress were observed.

Conclusion:

The results demonstrate that plication of the rectus abdominis increases intra-abdominal and pulmonary pressure without generating significant systemic changes.
Subject(s)


Full text: Available Index: LILACS (Americas) Main subject: Pressure / Reference Standards / Lipectomy / Prospective Studies / Longitudinal Studies / Rectus Abdominis / Abdomen Type of study: Evaluation studies / Observational study Limits: Adult / Female / Humans Language: English / Portuguese Journal: Rev. bras. cir. plást Journal subject: General Surgery Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Daher Lago Sul/BR / Sociedade Brasileira de Anestesiologia/BR / Sociedade Brasileira de Cirurgia Plástica/BR

Similar

MEDLINE

...
LILACS

LIS


Full text: Available Index: LILACS (Americas) Main subject: Pressure / Reference Standards / Lipectomy / Prospective Studies / Longitudinal Studies / Rectus Abdominis / Abdomen Type of study: Evaluation studies / Observational study Limits: Adult / Female / Humans Language: English / Portuguese Journal: Rev. bras. cir. plást Journal subject: General Surgery Year: 2017 Type: Article Affiliation country: Brazil Institution/Affiliation country: Hospital Daher Lago Sul/BR / Sociedade Brasileira de Anestesiologia/BR / Sociedade Brasileira de Cirurgia Plástica/BR